quarter of a turn.
Set the boiler thermostat knob to its minimum setting and
close the flue chamber damper plate to No. 1 setting. Set
the cooker/boiler chamber knob to ‘C’ to obtain optimum
heat into oven and hot plate.

NOTE: THE BEST POSITION FOR THE FLUE
CHAMBER DAMPER CAN BE FOUND ONLY BY
EXPERIMENT BUT ALWAYS TRY THE LOW SETTING
FIRST.

In the morning, open the spinwheel three complete turns,
the flue chamber damper to maximum and riddle the fire.
When it is burning brightly, close the flue chamber
damper, but do not refuel before use if the hotplate is
required immediately.

All Fuels.

Set the cooker/boiler damper knob ‘H’.
Close spinwheel.
To regulate burning, set the boiler thermostat knob to ‘8’
(high) or minimum rate ‘1’ (low).
Adjust as required to suit desired water heating.
Overnight banking and daytime slow burning should be
obtained with the boiler thermostat knob set at ‘1’ to give
extended burning.

Woodburning

Some wood are more difficult to burn therefore it may be
necessary to open the spinwheel in addition to the
thermostat to obtain the desired results. The spinwheel
must be closed as appropriate.

Solid Fuel

The appliance may be operated overnight for the
purpose of selected central heating when inclement
weather conditions occur.
Set the cooker/boiler damper knob to ‘H’ after refuelling
etc. and the boiler thermostat knob to No. 2 with the flue
chamber damper set at minimum. The spinwheel should
be closed and about four radiators can be run overnight
under these conditions.

NOTE: THE HOTPLATE AND OVEN TEMPERATURE
WILL BE CONSIDERABLY LOWER AND EXTENDED
TIME WILL BE NEEDED TO HEAT UP THESE
FEATURES. DO NOT FORGET TO RE-SET THE
COOKER/BOILER KNOB TO ‘C’ FOR COOKING
AFTER OVERNIGHT USE.

Wood

The appliance is designed for continuous slumbering
overnight for up to a maximum of 12 hours depending on
the type of dry wood being used. Last thing at night, open
the flue chamber damper. de-ash the fire, empty the
ashpan and fully refuel.

Ensure that the firebox and ashpit door are securely
closed

, close the spinwheel tight and the flue chamber

damper is set to No.1.
Set the boiler thermostat knob to its minimum setting
and the front damper knob to ‘c’.
Turn the flue dilution lever (See Fig. 7) from left to right
hand so that the flue chamber door opens at the bottom
and minimise burning rates.

NOTE: THE PRECISE AMOUNT OF OPENING
DEPENDS ON THE CHIMNEY DRAUGHT, THE
TYPE/CONDITION OF WOOD TO BE BURNT AND
THIS MAY TAKE 2 OR 3 DAYS TO ASCERTAIN

.

1. If the fuel in the firebox is exhausted prematurely, the 

overnight chimney draught must be reduced by 
increasing the opening setting of the flue chamber 
door, using the flue dilution lever.

2. If the fuel does not burn but ‘dies out, the draught 

should be increased by reducing the opening setting.

of the flue chamber door, using the flue dilution lever.
Following overnight banking, the flue chamber door must
be closed, the spinwheel and flue chamber damper
opened and the fire refuelled.
Immediately the new fuel has caught alight, riddle the fire
and close the flue chamber damper.

NOTE: BUILD-UP OF CREOSOTE DEPOSITS IN THE
FLUE AND CHIMNEY CAN IN TIME, LEAD TO
CHIMNEY FIRE.
THESE DEPOSITS CAN BE PREVENTED BY THE
REGULAR USE OF A PROPRIETARY BRAND OF
CHEMICAL CREOSOTE REMOVE CHIMNEY
CLEANER SUCH AS “ATTACK” WHICH REDUCES
THE ADHESION STRENGTH OF THE CREOSOTE
DEPOSITS, CAUSING THEM TO FAIL.
IMPORTANT: CHEMICAL CLEANERS MUST NOT BE
CONSIDERED AS AN ALTERNATIVE TO CHIMNEY
SWEEPING, ONLY AS SUPPLEMENTARY.

Against Thermostat knob settings with Cooker/Boiler
Damper at ‘H’ and Spinwheel closed.

Thermostat Setting No.

Water Temperature

(APPROXIMATE)

1

46ÞC (115ºF)

3

54.5ÞC (130ºF)

5

65.5ÞC (150ºF)

8

80ÞC (176ºF)

a) Using the cooker boiler to provide heat for domestic
hot water and radiators in the winter, a boiler thermostat
setting at No.8 is recommended.
b) Using the cooker boiler for the provision of domestic
hot water only, in the summer, a boiler thermostat setting
of No. 5 is recommended.
NOTE: TO CONSERVE FUEL, ENSURE THE HOT
WATER CYLINDER AND PIPES ARE LAGGED WITH
INSULATION.

BOILER CENTRAL HEATING

THERMOSTAT SETTING

OVERNIGHT CENTRAL HEATING

TYPICAL WATER

TEMPERATURES

OVERNIGHT BANKING

5

Содержание 355m

Страница 1: ...se note that some original pages may not appear in original numerical order but have been rearranged for clarity or deleted if not appropriate WARNING This information is a copy of an original archive therefore Aga cannot be held responsible for its continued accuracy or relevance ...

Страница 2: ...ating and domestic use normal setting for winter usage whilst manually operated spinwheel control on the front of the ashpit door will provide heat for cooking and domestic hot water normal setting for summer usage The cooker boiler flueway damper knob on the centre front of the cooker below the top plate requires to be set in conjunction with the flue chamber damper to obtain the appropriate serv...

Страница 3: ...m the locking spindle and pull the door open To close the doors Gently push the door shut until the door catch makes contact with the locking spindle FIRE DOOR OPERATION SEE FIG 3 To open the door Lift the door by the handle and pull forward To close the door Lift the door up by the handle and push to shut THE FIREDOOR MUST BE LIFTED SLIGHTLY WHEN OPENING AND CLOSING OTHERWISE DAMAGE TO THE DOOR C...

Страница 4: ...l supply of wood and paper on top of the bottomgrate bars together with a small quantity of fuel and light i Close and lock the ashpit door with the spinwheel control open j Close and lock the firedoor k With fire established open firebox door and fill firebox with fuel Check secondary air slide setting Fig 6 Close and lock firebox door Push flue chamber damper back to position which has been foun...

Страница 5: ...uels Three complete turns during cooking periods After setting the cooker boiler damper knob to C set the flue chamber damper fully open after refuelling and reset to position which has been found by practical experience to give the best results Do not try to obtain a fast increase in temperature by opening flue chamber to its fullest extent This results in most of the heat being wasted up the chi...

Страница 6: ...box and ashpit door are securely closed close the spinwheel tight and the flue chamber damper is set to No 1 Set the boiler thermostat knob to its minimum setting and the front damper knob to c Turn the flue dilution lever See Fig 7 from left to right hand so that the flue chamber door opens at the bottom and minimise burning rates NOTE THE PRECISE AMOUNT OF OPENING DEPENDS ON THE CHIMNEY DRAUGHT ...

Страница 7: ...the grate when riddling and may even cause jamming Allow the fire to burn out and then open the ashpit door Lift off the clinker door See Fig 10 and insert hooked poker to drawn out any offending accumulation Replace clinker door after use The amount of clinker formation is dependent on the heating load or burning rate and should be checked weekly for any build up Excessive build up will lead to a...

Страница 8: ...n monoxide a poisonous gas into the room Failure to ensure clean flueways flue pipes and bends may lead to emission of dangerous gases and an inferior performance from your appliance Cooker Flueway Allow the fire to burn out open the flue chamber damper to its maximum and remove the flue chamber door Turn the cooker boiler knob C Brush the soot or fly ash from the flue pipe allowing it to fall ont...

Страница 9: ...vidual bar pulling forward to remove NOTE THERE ARE TWO TYPES OF BARS ASSEMBLED AND THE REPLACEMENT BARS SHOULD BE CHECKED AGAINST REPLACED BAR BEFORE REPLACEMENT The firebricks fitted to the Rayburn 355M are of first quality manufacture and providing the cooker has been installed and used correctly will have a reasonable life They are however expendable items and in time will require renewal Repl...

Страница 10: ...ent parts if required are always available ex works Write to us should any difficulty be encountered in obtaining them from your usual supplier SMOKE SMELL EMITTED DURING INITIAL USAGE Some parts of the cooker have been coated with a light covering of protective oil During initial operation of the cooker this may cause smoke smell to be emitted and is normal and not a fault with the appliance it i...

Страница 11: ...10 ...

Страница 12: ...11 ...

Страница 13: ...policy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www aga web co uk www agacookshop co uk www agalinks com ...

Страница 14: ... are designed and constructed to meet the required safety standards when properly installed and used IMPORTANT NOTICE PLEASE READ THE ACCOMPANYING WARRANTY Any alteration that is not approved by Aga could invalidate the approval of the appliance operation of the warranty and could also affect your statutory rights Control of Substances Health and Safety Important This appliance may contain some of...

Страница 15: ... boiler damper knob at C will produce 1 46kW 5 000 Btu h of hot water from the boiler Summer Use See para re Firebrick Positions With the cooker boiler damper knob at C and the oven maintained at roasting temperature the hot water output from the boiler will be 2 6kW 9 000 Btu h of hot water from the boiler Overnight banking with the cooker boiler damper knob at C will produce 1 46kW 5 000 Btu h o...

Страница 16: ...ic lined and comply with BS 4543 The minimum diameter for a straight chimney is 175mm and if offsets are fitted the recommended minimum diameter is 200mm IN ALL TYPES OF CHIMNEYS THE MINIMUM HEIGHT FOR CORRECT OPERATION OF THE COOKER IS 5 5m AND SHOULD TERMINATE ABOVE THE ROOF IN ACCORDANCE WITH REGIONAL STATUTORY REQUIREMENTS RECOMMENDED FLUE DRAUGHT 2mm W G 0 08in MINIMUM THE APPLIANCE SHOULD BE...

Страница 17: ...AIN PIPE ARE NOT RECOMMENDED BUT CERTAIN PROPRIETARY MAKES OF INSULATED CHIMNEY ARE SUITABLE Provision must be made for a permanent unobstructed air vent having a minimum effective area of 182 5cm2 28 25sq in communicated directly to outside air or an adjacent room which itself has a permanent air vent of at least the flue size direct to outside air Effect of Extractor Fan Avoid if possible the in...

Страница 18: ...ation or maintenance The Rayburn 355M is delivered complete including a set of boiler removable firebricks where positional location determines the amount of hot water supplied in winter and summer seasons The oven side and firebox front firebricks are permanently fixed with fire cement whilst the two boiler face side bricks and boiler back brick are located for the summer season thereby providing...

Страница 19: ...bottomgrate bars are in position Operate the riddling lever to ensure bottomgrate operation 4 Turn the boiler thermostat knob at the rear left hand corner of the top plate from No 1 low to No 8 high NOTE THE HIGHER THE NUMBER THE HIGHER THE WATER TEMPERATURE The handrail brackets are held on the front ends of the cooker top plate casting Remove the travel nuts and replace with the handrail bracket...

Страница 20: ...7 ...

Страница 21: ...olicy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www aga web co uk www agacookshop co uk www agalinks com ...

Отзывы: