25
information outlined in the Precautions section.
NOTE
: The fan turns on when the unit’s internal heat
reaches 122°F (50°C).
Error Codes
The Raya SDR-400’s LED screen will indicate one of
the following codes when it detects an issue.
E1
= One or more of the capacitors is overvolting. If
this error occurs, turn the unit off and let it rest for a
few minutes. If the error message comes up again,
contact the manufacturer.
E2
= The monolight is overheating (176°F, 80°C). The
error will disappear once the unit has cooled. Press
any button (except the power button) to remove the
error message. The fan will continue to cool the unit
until the heat has dissipated after 5-10 minutes. If
the monolight is turned off, the light will take longer
to cool.
E3
= The monolight’s input voltage is more than 265
volts. If this error occurs, turn the unit off and let it
rest for a few minutes. If the error message comes up
again, contact the manufacturer.
Содержание SDR-400