RECEIVER UNITS JRAEA-JRAEB
—————————
————————————————
ENG
23
POWER SUPPLY CONNECTION
Before connecting the power supply verify the voltage
available on the controlled machine.
Receiver power supply must compulsorily be provided by
means of a transformer or a double-insulation power
supply unit and protected by a bipolar switch, with
protection against over-current and with contact opening
at least 3mm. wide. The switch must be mounted
between 0,6 e 1,9 meters from the floor, and must be
equipped by a blocking device preventing unauthorized
restart.
FROM LINE
TO RECEIVER
CABLE REQUIREMENTS
For connecting the receiver unit it is mandatory to use
cables compliant to the following requirements:
- INSULATION 500V
- FIREPROOF ACCORDING TO UL94-V/0
COMMAND CABLE
PG21 = 32 x 0,75 mm
2
MAX. DIAM. 15 ÷ 18 mm
POWER SUPPLY CABLE
PG9 = 2 x 0,75 mm
2
MAX. DIAM. 6 ÷ 8 mm
RELAYS ACTIVATION FROM THE TRANSMITTER UNIT
Refer to the enclosed connection sheet to see how commands on transmitter units
3
and
receiver relays are connected.
3
Refer to the transmitter unit manual for further details – doc. ref. A,B,C,D