Installation
Installation must be carried out only by qualified personnel and according to
relevant regulations.
GENERAL INSTRUCTIONS
To properly install the receiver unit it is mandatory to follow some simple rules and
precautions
in order to guarantee that the system works at its best.
The interconnection to the controlled machine must be accomplished by means of
a multiple plug, thereby allowing, when necessary, an easy restoration of the
original wired commands – if present.
Before starting the installation identify the interconnection points on the electrical
diagrams of your controlled machine, verifying that power supply and rated load
specifications are compatible with the radio remote control parameters provided in
this manual.
Start installing the cable from the receiver side, after move towards the plug, with
the aid of the interconnection diagrams shown in the enclosed connection sheet.
MOUNTING HOLES
C
D
F
G
A
B
A = 312mm
B = 318mm
C e G = 140mm
D e F = 174mm
MECHANICAL MOUNTING
Receiver unit must be installed far from
heating sources and must not be shielded
by large metallic surfaces; installation
height must be approximately between 0,4
and 1,5 meters from the floor, ensuring a
minimal passage space (height 1,4
meters, length 1 meter). In case of heavy
vibrations, it is compulsory to use proper
anti-vibration supports provided on request
by RAVIOLI