background image

M7 GX Technical Manual 

5

 

Raveon Technologies Corp. 

6.3. 

Setting a Parameter 

To set a parameter in the 

M7 GX

 modem, enter the Command Mode as described above, then enter the 

proper command, a space, the parameter, and then a carriage return.  For Example, to set the destination 
address of the 

M7 GX

 modem to 25, enter the following command: 

ATDT 25

 <CR>. 

6.4. 

CONFIG Button 

If certain parameters within the 

M7 GX

 transponder are modified in a manor that causes the modem to cease 

functioning or if the user cannot enter the command mode via the “+++” method, there is a small push-button 
inside the 

M7

 to assist.   This “CONFIG” button may be pressed at any time, and forces the 

M7 GX

 into a 

known state.  The CONFIG button is located inside the 

M7 GX

.  Remove the rear cover, exposing the circuit 

board and he button as shown below.  

 

The default settings that the 

M7 GX

 will revert to when the CONFIG button is pressed are: 

1.  Serial port 9600 baud, 8 data bits 1 stop, no parity 

2.  Serial port flow control is off. 

3.  ATCT setting set to 60000 (60 second time-out) 

Even though the serial baud rate reverts to 9600 baud when the CONFIG button is pressed and the IO port 
is RS232, it will revert back to the settings programmed into the 

M7 GX

 once the Command Mode is exited.   

7.   Commands to Configure Radio Operation 

 

Command

 

Command Description

 

Parameters

 

Factory

 

Default 

 

ATBD 

Baud Rate 

– Sets serial com port baud rate (bps).  Over-the-air 

(throughput) baud rate is set with ATR2 command.  
If a PC’s serial baud rate is set higher than the fixed over-the-air 
baud rate of the module, hardware handshaking may be required.  

Range: 0 – 7  
0 = 1200     5= 38400 
1 = 2400     6=57600 
2 = 4800     7=115200 
3 = 9600  
4 = 19200  

ATDT 

Destination Address to call

– Sets address of the modem to send 

data to.  Note, this parameter is entered in HEX format. Each digit 
may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or an F.  

Range: 0-FFFF 

1234 

ATF 

Display frequencies 

– Display all of the frequencies programmed into all of the 

channel memories.

  

 

N/A 

ATFT 

Transmit Frequency – 

Program the transmit frequency for this channel. Enter in 

Hz or in MHz.  The frequency will automatically be saved in non-volatile memory 
(flash) for this current channel number.

 

Range: See product data 
sheet.  For MURS products, 
frequency cannot be 
changed. 

See product data 

sheet. 

ATFR 

Receive Frequency – 

Program the receive frequency for this channel. Enter in 

Hz or MHz. The frequency will automatically be saved in non-volatile memory 
(flash) for this current channel number.

 

Range: See product data 
sheet.  For MURS products, 
frequency cannot be 
changed. 

See product data 

sheet. 

ATFX 

TX and RX Frequency – 

Program the receive and transmit frequency for this 

channel. Enter in Hz or MHz. Same as issuing an ATFR and an ATFT command.  
The frequency will automatically be saved in non-volatile memory (flash) for this 
current channel number.

 

Range: See product data 
sheet. 

N/A 

Содержание RV-M7 GX WX

Страница 1: ...Technologies Corp RV M7 GX G P S T r a n sp o n d e r Quick Start Guide Version C0 February 2010 RV M7 GX RV M7 GX WX Raveon Technologies Corporation 990 Park Center Drive Suite C Vista CA 92081 www...

Страница 2: ...and a radio modem for sending and receiving data The M7 GX may be configured for a number of different GPS applications including Transponder Periodically transmit position and status TX only RavTrack...

Страница 3: ...transponders within radio range GPS 5 LX No GPS module Lowrance and Garmin GPS displays Radar displays Mobile displays 38400 PRAVE Connect the M7 GX to a PC running RavTrack PC or change the message t...

Страница 4: ...reporting GND or floating for a 0 3V for digital 1 8 CTS out Clear to send Used to stop the flow of data going into the RxD pin from the device connected to the M7 0 OK to send 1 don t send 9 Power In...

Страница 5: ...eters Factory Default ATBD Baud Rate Sets serial com port baud rate bps Over the air throughput baud rate is set with ATR2 command If a PC s serial baud rate is set higher than the fixed over the air...

Страница 6: ...ATRV Disable Remote Access When enabled set to a 0 the modem will respond to over the air RPR requests Pings and over the air commands 0 Remote Access on 1 Remote Access disabled 1 ATSL Serial Number...

Страница 7: ...e The length of one TDMA time frame in seconds M7 s may transmit once per frame and only in their preset time slot 1 3599 10 TRIGPOL Polarity of the input bits 0 normal active high operation causes un...

Страница 8: ...s the KEYPHRASE programmed into all the other M7 GX transponders in your system The factory default KEYPHRASE is RAVEON call capitols 12 To see an overview of how the modem is configured use the SHOW...

Страница 9: ...GX transponders at ID 0001 The second M7 should be ID 0002 and so on The M7 GX transponders have internal clocks with 20 ticks per second They can measure time and initiate transmissions 20 times ever...

Страница 10: ...with the antenna and properly ground the antenna and the M7 chassis to an earth ground 8 Connect Digital Inputs The stock M7 GX has up to 3 digital inputs using the input pins of the RS 232 serial por...

Страница 11: ...ta communication via RS232 also Capable of Speed triggered position reports Speed Trigger default Minimum Distance Trigger Digital Input Triggers Serial Port Baud Rate Can be a repeater Command used t...

Страница 12: ...Manual 12 Raveon Technologies Corp For Technical Assistance email or call Raveon at Raveon Technologies Corporation 990 Park Center Drive Suite C Vista CA 92081 760 727 8004 www raveontech com sales...

Отзывы: