background image

8

2.

The 

Tank

 or 

Bin Indicator

 displays the calculated volume of product remaining 

in the tank or bin. Touch this indicator to display the 

Tank

 

or 

Bin Volume 

Configuration

 screen.

3.

The 

Area Covered

 displays a tally of the total area covered by active sections 

(sections toggled on) within the current job.

4.

The 

GPS Status

 status indicator is displayed on the Guidance screen. See the 

GPS Status Indicator

 section on page 2 for more information.

5.

Touch the 

Display Mode

 icon to toggle the day or night modes for the guidance 

screen display.

6.

This area displays the 

Speed

 or 

Course Over Ground (COG)

. Touch this area 

to toggle the information displayed.

7.

The 

Distance to Swath

 display shows the distance and direction to the 

displayed Guidance path.

8.

The 

SmarTrax™ Status

 

is displayed if an optional SmarTrax™ or QuickTrax™ 

system is connected to the Envizio Pro. This indicator appears 

green

 if the 

system is engaged or 

red

 if the system is disengaged.

9.

The current status of 

Wireless Communication 

is displayed on the guidance 

screen. See the 

Wireless Communications Status

 on page 3 for more 

informaiton.

10.

The 

Product Rate Display

 

shows target and actual application rates as well 

as indicates the selected product.
Touch the name of a product to toggle the selected product or touch in the rates 
area to access the 

In Job Product Configuration

 screen. Additional display 

options may be activated on the 

In Job Product Configuration

 screen.

11.

Touch the 

Rate Bump

 buttons to increase or decrease the rate of the selected 

product. When operating in 

Automatic

 control mode, the rate bump buttons will 

increase or decrease the target rate. In 

Manual

 control mode, these buttons will 

adjust the actual application rate.

12.

The 

AccuBoom Override

 

13.

The 

AutoBoom™ Status Indicator

 is displayed if an optional AutoBoom™ 

system is connected to the Envizio Pro. See the AutoBoom™ section for more 

information regarding the AutoBoom™ Status Indicator.

14.

The 

Section Status

 

Display

 shows information for each configured section. 

Active sections appear 

green

 while sections currently disabled (or toggled off) 

appear in white.

15.

The 

Swath Information

 displays the number of the current swath when using 

the Straight Line, Fixed Contour, or Pivot patterns. When using the Enhance 
Last Pass pattern, this area displays 

LAST

.

16.

The 

In-Job Nudge Settings

 

17.

Use the 

Zoom In

 and 

Out

 icons to change the level of detail shown on screen.

18.

Touch the 

Alternate Guidance Pattern

 button to toggle the pattern used to 

provide guidance for the job in progress.

19.

Access the 

Menu

 to display additional tools and features of the job in progress. 

The Menu contains the tools for recording a field boundary and creating or 
editing a Guidance Path.

Содержание Envizio Pro

Страница 1: ...Quick Reference Guide Envizio Pro...

Страница 2: ...n TM 1 Tilt Module for tilt corrected guidance Startup To power up the Envizio Pro console press the power button located on the right side of the Envizio Pro console Do s and Don ts Do have the Enviz...

Страница 3: ...utdown icon on the Home screen Info icon in the upper right corner of the display to view the current software and firmware versions of the Envizio Pro console If the Envizio Pro is connected to a CAN...

Страница 4: ...e and Setup Wizard menus Quick Access Bar While working in the Tools Menu the Quick Access Bar remains at the top of the screen and allows access to the Setup Wizard System GPS Computer and Vehicle me...

Страница 5: ...the currently loaded profile highlighted in the list of profiles stored on the Envizio Pro To Create a New Profile Touch the icon and use the on screen keyboard to enter the desired profile name To Sa...

Страница 6: ...ole Touch the All button on to perform the selected action on all of the files displayed in the list For example select the Unload All to USB Drive to transfer all the jobs onto the connected USB flas...

Страница 7: ...Select the desired baud rate for the output messages from the list on the right side of the screen Start a Job 1 To begin a job touch the icon on the Home screen The Start Job Verify Settings screen w...

Страница 8: ...oom system will be used the system may be enabled by selecting the AutoBoom button See the AutoBoom section in this guide or the AutoBoom Calibration Operation manual for more information 9 When finis...

Страница 9: ...he selected product or touch in the rates area to access the In Job Product Configuration screen Additional display options may be activated on the In Job Product Configuration screen 11 Touch the Rat...

Страница 10: ...ctive To Load an A B Line Touch the Load A B Line icon to load a previously saved line into the current job This icon will not appear if an A B Line has already been set Reset the line to access the L...

Страница 11: ...con to move the guidance path to the left in the increments set on the Nudge Settings screen Recording a Field Boundary To Record a Field Boundary 1 Begin a job file by following the procedure outline...

Страница 12: ...creen to display the AccuBoom Override icon on the Guidance screen 2 The Turn Off Percent value sets the percentage of the boom section width that must be in a previously applied area or no spray zone...

Страница 13: ...Guidance screen will re appear and Envizio Pro will begin recording the boundary or feature On the Guidance screen a Pause and End icon appear for the feature currently being recorded The Guidance scr...

Страница 14: ...e procedure in the Start a Job section earlier in this guide and select the to begin guidance 4 Before guidance will begin the operator will be prompted to review the Glide Series AutoBoom system sett...

Страница 15: ...CANbus ends not terminated Make sure that both ends of the CANbus system are properly terminated Refer to the Envizio Pro Installation Operation manual for more information Corroded pins in CANbus con...

Страница 16: ...Industries Inc All rights reserved under copyright laws Raven Industries Toll Free U S and Canada 800 243 5435 Applied Technology Division or Outside the U S 1 605 575 0722 P O Box 5107 Fax 605 331 04...