background image

1 1

Touch the 

Delete Boundary

 icon to reset the current Field Boundary. A field 

boundary must be present in the current job or this icon will not appear in 
the Menu.

Touch the 

Record Field Boundary

 icon to begin recording a New Field 

Boundary. While a Field Boundary is being recorded, the Pause and End 
Field Boundary icons are displayed on the Guidance screen.

AccuBoom™

The following sections offer an overview of the optional Raven AccuBoom™ 
system when used with the Envizio Pro console. Refer to the 

Envizio Pro 

Installation & Operation

 manual for additonal information regarding the 

AccuBoom™ system.

Setup

To view current settings for an optional AccuBoom™ system, touch:

The 

AccuBoom Configuration

 

screen will be displayed.

1.

The 

On Override

 option is the the 

number of seconds for the 
AccuBoom™ Override. Be sure to 
check the 

Enable Override 

Popup

 option at the bottom of the 

screen to display the AccuBoom™ 
Override icon on the Guidance 
screen.

2.

The 

Turn Off Percent

 value sets 

the percentage of the boom 
section width that must be in a 
previously applied area, or no-
spray zone, before AccuBoom™ 
will control that section.

3.

Touch the 

Boom Selection

 button to select the boom sections which 

AccuBoom™ will automatically control.

4.

Adjust the 

On

 or 

Off Look Ahead

 settings to compensate for the time required 

to open or close the control valve.

5.

Select the 

Aggressiveness

 setting best suited for the field conditions and 

driving style. For more information on the AccuBoom aggressiveness feature, 
refer to the 

Envizio Pro Installation & Operation Manual.

Operation

If the 

Use Spray Zone Map

 option has been enabled for the active job (see the 

Start a Job

 section), the 

Menu

 will contain tools for recording AccuBoom™ Spray 

Zone Map features.

To Load a Spray Zone Map with a Job in Progress:

1. Begin an AccuBoom™ enabled job with the 

Use Spray Zone Map

 option 

enabled (refer to the 

Start a Job

 section earlier in this guide).

Tools Menu

System 

Menu

AccuBoom

1

2

3

4

5

Содержание Envizio Pro

Страница 1: ...Quick Reference Guide Envizio Pro...

Страница 2: ...n TM 1 Tilt Module for tilt corrected guidance Startup To power up the Envizio Pro console press the power button located on the right side of the Envizio Pro console Do s and Don ts Do have the Enviz...

Страница 3: ...utdown icon on the Home screen Info icon in the upper right corner of the display to view the current software and firmware versions of the Envizio Pro console If the Envizio Pro is connected to a CAN...

Страница 4: ...e and Setup Wizard menus Quick Access Bar While working in the Tools Menu the Quick Access Bar remains at the top of the screen and allows access to the Setup Wizard System GPS Computer and Vehicle me...

Страница 5: ...the currently loaded profile highlighted in the list of profiles stored on the Envizio Pro To Create a New Profile Touch the icon and use the on screen keyboard to enter the desired profile name To Sa...

Страница 6: ...ole Touch the All button on to perform the selected action on all of the files displayed in the list For example select the Unload All to USB Drive to transfer all the jobs onto the connected USB flas...

Страница 7: ...Select the desired baud rate for the output messages from the list on the right side of the screen Start a Job 1 To begin a job touch the icon on the Home screen The Start Job Verify Settings screen w...

Страница 8: ...oom system will be used the system may be enabled by selecting the AutoBoom button See the AutoBoom section in this guide or the AutoBoom Calibration Operation manual for more information 9 When finis...

Страница 9: ...he selected product or touch in the rates area to access the In Job Product Configuration screen Additional display options may be activated on the In Job Product Configuration screen 11 Touch the Rat...

Страница 10: ...ctive To Load an A B Line Touch the Load A B Line icon to load a previously saved line into the current job This icon will not appear if an A B Line has already been set Reset the line to access the L...

Страница 11: ...con to move the guidance path to the left in the increments set on the Nudge Settings screen Recording a Field Boundary To Record a Field Boundary 1 Begin a job file by following the procedure outline...

Страница 12: ...creen to display the AccuBoom Override icon on the Guidance screen 2 The Turn Off Percent value sets the percentage of the boom section width that must be in a previously applied area or no spray zone...

Страница 13: ...Guidance screen will re appear and Envizio Pro will begin recording the boundary or feature On the Guidance screen a Pause and End icon appear for the feature currently being recorded The Guidance scr...

Страница 14: ...e procedure in the Start a Job section earlier in this guide and select the to begin guidance 4 Before guidance will begin the operator will be prompted to review the Glide Series AutoBoom system sett...

Страница 15: ...CANbus ends not terminated Make sure that both ends of the CANbus system are properly terminated Refer to the Envizio Pro Installation Operation manual for more information Corroded pins in CANbus con...

Страница 16: ...Industries Inc All rights reserved under copyright laws Raven Industries Toll Free U S and Canada 800 243 5435 Applied Technology Division or Outside the U S 1 605 575 0722 P O Box 5107 Fax 605 331 04...

Отзывы: