3
Envizio Pro or Envizio Pro II Bracket (P/N 107-0171-841)
Note:
The supplied mounting bracket must be attached to the Envizio Pro or
Envizio Pro II field computer so that the CAN Switch Box is mounted below
the field computer.
1. Set the mounting bracket over the mounting posts on the back of the field
computer.
2. Set the RAM mounting arm over the mounting plate and secure using four
screws (P/N 311-0007-015).
3. Align the CAN Switch Box with the remaining predrilled holes and secure using
two lock washers (P/N 313-4000-007) and two screws (P/N 311-0001-007).
Cable Connections
The CAN Switch Box connects to the control console and CANbus system with
the Viper Pro/Envizio Pro chassis interface cable (P/N 115-0171-926).
To connect the CAN Switch Box:
1. Connect the 4-pin Deutsch connector on the console or interface cable to the
CANbus port on the back of the CAN Switch Box.
2. Connect the 2-pin Deutsch connector on the console or interface cable to the
switched power port on the back of the CAN Switch Box.
3. If connecting to an Envizio Pro using the chassis interface cable (P/N 115-0171-
926), connect the round, 3-pin connector on the interface cable to the speed
sensor port on the back of the CAN Switch Box.
Note:
If the CAN Switch Box is connected as instructed above, the switch box will
be powered on or off using the Raven console or field computer switched
power. Refer to the console or field computer manual for instructions to
properly power down the console.
CANbus
Mounting Posts
Switched
Power
Speed
Sensor