background image

Page 4

As the Sara Insert Wood Pellet Fire is typically 
installed in new homes, it is necessary to build a 
compliant cavity that will house the fi re and the frame.  
The front facia of the enclosure must be made of a 
fi reproof rated board (above 80°C) such as (but not 
limited to) Micore, Supalux or Eterpan, and this must 
extend to a minimum of 600mm above the top of the 
fi re.  Within the cavity, there must be a minimum of 
300mm clearance to combustibles above the fi re, and 
a minimum 600mm gap between the top of the fi re 
and the ceiling of the cavity. The cavity also requires 
a minimum of 100cm

2

 ventilation.

WALL WALL WALL WALL WALL WALL WALL WALL

L

N

K

M

Built-in  fi re clearances don’t apply in a non-combustible 
cavity.  The above clearance to combustibles on the fl ue 
are only applicable within the fi re envelope.  Clearance 
outside this eg at a ceiling/wall thimble reverts to 25mm as 
per ARS fl ue test 05/1185.

If installing a fl oating hearth, ensure suffi cient
clearance is left below the fi re to allow for installation
of the chosen surround.

Exterior of Cavity

D

E

J

H

VENT

F

B

C

A

G

I

J

VENT

Interior of Cavity

5.  

Creating the Cavity

Internal Cavity Dimensions

(A) Width:

 1050mm 

(min)

(B) Depth

: 700mm 

(min)*

(C) Height:

 

1460 - 1740mm**

*  Includes 100mm clearance from rear of 

fl ue spigot box.

**  Dependendent on height at which the 

support frame is set.

Wall Opening

(D) Width:

 705mm

(E) Height:

 620mm 

Cavity Clearances to Combustibles

(F): from top of fi re

  

300mm

(G): from top of fi re to cavity ceiling

  

600mm

(H): from top of opening 

 

330mm (min)

(I): from side of opening 

 

210mm (min)

(J): from bottom of opening 

 

300 - 530mm, 

depending on height of support stand.

 

Additional Clearances to Combustibles

(K): from exhaust spigot to cavity wall

   100mm

(L): from side of fi re to cavity wall

  

210mm

(M): hearth depth from front of glass   

150mm

(N): hearth width 

 

1030mm

Surround Dimensions

Small Black (Flush) 

692mm(w) x 609mm (h)

Stainless Steel

 

914mm (w) x 830mm (h)

Содержание Sara

Страница 1: ...S ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FIRE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your local building or fir...

Страница 2: ...ire requires technical programming and individualised air pressure adjustments to ensure it will operate safely and efficiently and to avoid possible damage to the fire or the home Installation of the...

Страница 3: ...5 Example of Cavity Design Section View 5 Example of Cavity Design Top View 6 Adjusting the Support Frame 7 Seismic Restraint 7 Fixing to Concrete Floor 7 Fixing to Timber Flooring only 7 Fixing to Ti...

Страница 4: ...late 2 Sara must be installed on a non combustible surface This surface must protrude a minimum of 150mm from the front of the closed pellet fire door and a minimum of 200mm from the side of the appli...

Страница 5: ...manufactured to the AS NZS 4014 6 standard are recommended Dirty fuel will adversely affect the operation and performance of the unit and will void the warranty The Pellet Fuel Industries PFI has esta...

Страница 6: ...fied or authorised Modifications and repairs that are not authorized by the manufacturer Use of spare parts that are not original Exceptional events If you require further information please contact y...

Страница 7: ...ling wall thimble reverts to 25mm as per ARS flue test 05 1185 If installing a floating hearth ensure sufficient clearance is left below the fire to allow for installation of the chosen surround Exter...

Страница 8: ...Width 1030mm min B Depth 500mm min Includes 100mm clearance from rear of flue spigot box If this measurement is less than 500mm a custom surround will be required Ensure that extra depth required at...

Страница 9: ...all minimum distance to all combustible surfaces Andy modifications to the dimensions shown to be verified by consultation with the relevant Building Consent Authority 4 Ensure there is a minimum of...

Страница 10: ...enclosure 3 Comply with all minimum distance to all combustible surfaces Andy modifi cations to the dimensions shown to be verifi ed by consultation with the relevant Building Consent Authority 4 Ensu...

Страница 11: ...screws Thickness of flooring must be 20mm minimum The flooring shall be fixed to the nearest joist with two 8g x 40 screws per hold down anchor 12 Fixing to Timber Floor Framing Minimum 14g x 60 scre...

Страница 12: ...responsible for checking the installation instructions and clearance requirements of their electrical appliances to ensure the appliance is suitably located in relation to the wood pellet fire Nature...

Страница 13: ...r 100mm x 900mm long 4 2 Stainless steel inner liner 75mm x 900mm long 4 5 Inner outer flue liner spacer 2 8 Rain cap 75mm 1 9 Rain cap 100mm 1 10 Telescopic offset 75mm Stainless 2 x 45 bends 2 11 Te...

Страница 14: ...by a qualified technician All operations assume the fire is in the default OFF mode press button 3 to achieve this Some operations can also be performed in final cleaning use caution if the fire has b...

Страница 15: ...ill appear 4 Press 1 or 2 to change to your desired language 5 Press 3 twice to return to the main screen 17 3 3 Menu Four View Settings In this menu you can check the values of the parameters set in...

Страница 16: ...iver located on the right hand side of the stove Sometimes due to interference from other electrical household appliances microwave ovens satellite decoders mobile phones the connection between the st...

Страница 17: ...ower 1 PR06 Sec 1 6 Screw power 2 PR07 Sec 2 Screw power 3 PR08 Sec 2 4 Screw power 4 PR09 Sec 2 8 Screw power 5 PR10 Sec 3 2 Re start threshold PR11 C 80 No pellet threshold PR12 C 50 Off threshold P...

Страница 18: ...imate PR42 on off OFF Fan 2 speed 1 PR43 V Fan 2 speed 2 PR44 V Fan 2 speed 3 PR45 V Fan 2 speed 4 PR46 V Fan 2 speed 5 PR47 V Draft setting PR48 on off OFF or for version Air 03 Screw encoder PR49 on...

Страница 19: ...Green Yellow Green Yellow Green 7 8 11 12 9 10 3 4 Brown Brown Yellow Green Brown 10 9 Brown Blue Yellow Green Black Blue Blue Brown 1 6 6 5 5 6A 5A 1 2 2 6 Encoder Red Black White Black Brown White 7...

Страница 20: ...OLDQFH KDV EHHQ LQVWDOOHG DQG FRPPLVVLRQHG LQ FRPSOLDQFH ZLWK 0DQXIDFWXUHU V QVWDOODWLRQ UHTXLUHPHQWV DQG DSSURSULDWH 1HZ HDODQG 6WDQGDUGV RFDO RXQFLO UHTXLUHPHQWV Signed Date Declaration by Owner KHU...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...inspiring people to love the experience of sustainable wood pellet heat 0800 PELLET 0800 735 538 info naturesflame co nz www naturesflame co nz Nature s Flame PO Box 11 043 Sockburn Christchurch NZ...

Отзывы: