Page 4
As the Sara Insert Wood Pellet Fire is typically
installed in new homes, it is necessary to build a
compliant cavity that will house the fi re and the frame.
The front facia of the enclosure must be made of a
fi reproof rated board (above 80°C) such as (but not
limited to) Micore, Supalux or Eterpan, and this must
extend to a minimum of 600mm above the top of the
fi re. Within the cavity, there must be a minimum of
300mm clearance to combustibles above the fi re, and
a minimum 600mm gap between the top of the fi re
and the ceiling of the cavity. The cavity also requires
a minimum of 100cm
2
ventilation.
WALL WALL WALL WALL WALL WALL WALL WALL
L
N
K
M
Built-in fi re clearances don’t apply in a non-combustible
cavity. The above clearance to combustibles on the fl ue
are only applicable within the fi re envelope. Clearance
outside this eg at a ceiling/wall thimble reverts to 25mm as
per ARS fl ue test 05/1185.
If installing a fl oating hearth, ensure suffi cient
clearance is left below the fi re to allow for installation
of the chosen surround.
Exterior of Cavity
D
E
J
H
VENT
F
B
C
A
G
I
J
VENT
Interior of Cavity
5.
Creating the Cavity
Internal Cavity Dimensions
(A) Width:
1050mm
(min)
(B) Depth
: 700mm
(min)*
(C) Height:
1460 - 1740mm**
* Includes 100mm clearance from rear of
fl ue spigot box.
** Dependendent on height at which the
support frame is set.
Wall Opening
(D) Width:
705mm
(E) Height:
620mm
Cavity Clearances to Combustibles
(F): from top of fi re
300mm
(G): from top of fi re to cavity ceiling
600mm
(H): from top of opening
330mm (min)
(I): from side of opening
210mm (min)
(J): from bottom of opening
300 - 530mm,
depending on height of support stand.
Additional Clearances to Combustibles
(K): from exhaust spigot to cavity wall
100mm
(L): from side of fi re to cavity wall
210mm
(M): hearth depth from front of glass
150mm
(N): hearth width
1030mm
Surround Dimensions
Small Black (Flush)
692mm(w) x 609mm (h)
Stainless Steel
914mm (w) x 830mm (h)