Use and maintenance manual S70 - S90 - SC90
Pag.43
Rev.0 18/05/2020
Automatic mode
: When this function is activated, the stove automatically manages the 5 ducting levels.
To use automatic mode, two room temperature probes (optional) or external thermostats must be installed
in the room to be ducted to set the temperature of the room served by ducting, or else reading of the thermostat must be enabled,
following the steps below.
Press the
“Access to menu” key to
access the MENU screen
Press the
“confirm” key
to access the
UTENTE [USER] screen
Temperature (automatic mode)
Press the
“increase/decrease” keys
to modify ducting temperature.
In automatic mode, the output of the stove and of the two fans are managed independently, so as to reach and maintain the set
temperature in the relative environment.
To exit the screen to go back to the DUCTED menu, press the “back” key once; to go back to the Home screen, press the
“back” key several times.
Press the
“confirm” key
to go to the item
ABILITA T.EXT [ENABLE EXT.T].
Enabling is carried out
by pressing the “confirm” key
📌
The connection of the relative room temperature probe to the ducting is carried out by connecting the two poles at the back
of the stove where there is a quick coupling identified by the writing “T.EXT”.
Press the
“confirm” key
to go to the item
CANALIZZATA [DUCTED].
Press the “selection” key to
go to the item
TEMPERATURE
Press the key to save the
parameter and to go back to
the DUCTED MENU screen
Press the
“Access to menu” key to
access the MENU screen
Press the
“confirm” key
to access the
UTENTE [USER] screen
Press the
“increase/decrease” keys
to modify the setting.
Press the
“confirm” key
to confirm the new setting
Press the
“confirm” key
to go to the item
CANALIZZATA [DUCTED].
Press the “selection” key to
go to the item CUBATURA
[CUBATURE]
Cubature
To optimise automatic mode, set the cubature difference (m
3
) of the rooms during the installation stage.
you may choose from three options:
= EQUAL: if the cubature of the two rooms is more or less the same;
+ REAR: if the cubature of the room with ducting is larger than the one with the stove;
+ FRONT: if the cubature of the room with ducting is smaller than the one with the stove;
this way the stove will distribute more output to the larger room.
MENU
USER
DUCTED
USER
TECHNICIAN
MANUFACTURER
DUCTED
MANAGEMENT
TEMPERATURE
VENTILATION
CUBATURE
VIEW STATUS
FEED SCREW LOAD
CHRONOTHERMOSTAT
SET AIR-PELLET
T. DUCT. REAR
T. DUCT. REAR
T. DUCT. REAR
ENABLE EXT.T
ENABLE EXT.T
ENABLE EXT.T
T. DUCT. REAR
ENABLE EXT.T
USER
DUCTED
DUCTED
FEED SCREW LOAD
CHRONOTHERMOSTAT
SET AIR-PELLET
MANAGEMENT
TEMPERATURE
VENTILATION
CUBATURE
VIEW STATUS
MENU
CUBATURE
CUBATURE
CUBATURE
+ FRONT
+ FRONT
+ FRONT
+ REAR
+ REAR
+ REAR
USER
TECHNICIAN
MANUFACTURER