Use and maintenance manual Flexi 7 - Flexi 9
Pag.44
Rev.0 01/03/2023
EN
Stove phase general layout
PHASE
DESCRIPTION
FINAL CLEANING
The stove is in the switch off phase and the cooling phase has
not been completed yet.
IGNITION
The heater pre-heating phase has started and the pellets start to
fall into the grate.
FLAME LIGHT
The pellets ignite and take advantage of the heat in the intake air
that passes through the incandescent heater tube.
WORK
The stove has completed the switch on phase and runs at
maximum set power
MODULATION
The room temperature set has been reached.
FIRE POT CLEANING
Fire pot cleaning phase is active (periodic function).
ECO STOP
With Climate Comfort active, the stove switches to automatic
switch-off mode when the room temperature set is reached (see
the dedicated section).
WAITING START / RESTART
Switch-on is requested but with the stove in cooling phase; once
this condition is met, it restarts automatically.
IGNITION RESTART
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
HOT SMOKES
The maximum fume temperature threshold has been reached.
To facilitate cooling, the stove brings the capacity to a minimum
with ventilation at power level 5, leading to a decrease in fume
temperature.
OFF
The stove is off
WAIT FOR PELLETS OUT OF
When the switch-on request from ECO-STOP mode coincides
with an automatic switch-off condition (from the TIMER), the
stove turns on ensuring total cleaning of the fire pot before
switching to FINAL CLEANING.
AUGER OVERFLOW
CONDITION: when the pellet setting (set p5) is near the
continuous load condition.
SOLUTION: Set the value back to 0.
ALARM (generic)
The stove is in alarm state; refer to the troubleshooting chapter.