Use and maintenance manual S70 - S90 - SC90
Pag.27
Rev.0 18/05/2020
for the final installation and good operation of the installed product.
📌
Ravelli shall not be held liable if these precautions are not followed.
Requirements for the installation premises
The stove installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake
connected to the outdoors.
📌
The installation room must have an air intake with a free cross-section of at least 80 cm
2
.
📌
For installation in the presence of other combustion appliances or VMC system it is necessary to check the appliance for
correct operation.
The stove must be placed inside living quarters. It must never be installed outdoors. The volume of the room where it is installed
must be suitable for the power of the appliance and, in any case, greater than 15 m
3
.
⚠
When extraction fans (example: extraction hoods) are used in the same room or space as the stove, this can cause problems
to stove operation.
⚠
The stove must be installed on a floor with suitable load capacity. If the existing position does not fulfil this requirement, it is
necessary to take due measures (for example, using a load distribution plate).
⚠
provide due insulation if the surface is made of flammable material.
If the side walls adjacent to the stove are made of a flammable material, it will be necessary to position the stove at least 30 cm from
them.
If the floor that the stove is standing on is flammable, we recommend duly insulating it. Objects and parts that are heat-sensitive
or flammable cannot be stored near the stove;in any case, keep such objects outside the area bounded by the minimum distances
indicated above.
Stove installation must guarantee easy access to clean the appliance, the exhaust ducts and the chimney.