3.10  “ChOOse LangUage“ Menu

to set the language, proceed as follows:

1. press button p7, CLOCK setting MenU will appear.
2. press button p1 2 times: the display will show LangUage seLeCtiOn MenU.
3. access with button p7. the display will show the language selected.
4. With buttons p1 and p2, select the language desired, confirm with button p7.
5. Confirming with key p7 you return automatically to the  03 ChOOse LangUage menu.

3.11 activation of the COMFORt CLiMate

COMFORt CLiMate is activated by keeping p4 pressed and adjusting a temperature delta dedicated to restart (see chapter  1.2.1 
- e). another method to change the delta is to access parameters in “DeFaULt settings”. the parameter to be changed is pR 42 
(values vary from OFF to 20°C).
after reaching the set room temperature, after 255’’ the stove goes from MODULe WORK to eCO stOp mode, executing a FinaL 
CLean in underground. When room temperature goes below 

tset amb. - delta on/off

the stove executes the phases relating to manual ignition (pressing of key p3 after “FinaL CLean”), as clearly illustrated in paragraph 
6.0.

3.12 how to associate the remote control to the stove

all input stoves are equipped with radio-wave, palm remote controls and a receiver located on the right-hand side of the stove.
sometimes, due to interference caused by other electric devices (microwave ovens, satellite decoders, mobile phones,  cb , .... ) the 
link between the stove and the remote control is interrupted (no field).
to reinstate the connection, proceed as follows:
- switch the stove off
- unplug the power supply lead
- on the remote control,  press the triangle keys 1 and 2 for about 3 seconds
- with triangle key 2, select the frequency unit to be loaded ( choose unit 0 , 1 , 2 , 3 )
- reconnect power supply by plugging in the lead
- press red key 
if the operation is successful, the screen on the remote control will show Unit LOaDeD 0 , 1 , 2 , 3

4.0 aLaRMs

if an operating anomaly should occur, the motherboard intervenes and warns that an irregularity has occurred operating in various 
ways depending on the type of alarm. two alarms are charted below.

alarm origin

Code

Display showing

smoke temperature probe

02

sMOKe pROBe aLaRM

smoke over-temperature

03

sMOKe OVeR-teMp. aLaRM

nO ignitiOn

05

nO ignitiOn aLaRM

Flame anomaly

11

FLaMe anOMaLY aLaRM 

extinction during work phase

06

peLLets FinisheD aLaRM

Black-out

01

BLaCK - OUt

Vaccum switch

08

DepRessiOn aLaRM

general safety thermostat (on side of hopper)

07

theRMaL saFetY aLaRM

Faulty exhaust blower

04

FaULtY Fan aLaRM

exhaust blower anomaly

12

sMOKe eXtRaCtOR ReVs anOMaLY

auger blockage

-

sCReW BLOCKage aLaRM

Содержание Ecotek FLOW LINE

Страница 1: ...INSTALLER S MANUAL FOR FLOW LINE DESIGN LINE BOX LINE models Rev 1 for models with FLASH motherboard 01 NOV 6th 2008 For USA CANADA 110v 60 hZ F...

Страница 2: ...n the hopper is filled 7 the pellets are loaded into the firepot 3 by means of the auger 1 Ignition takes place via the ignitor 2 that overheats the air coming from the inlet 5 which when in contact w...

Страница 3: ...ATA DRWG NR N DISEGNO DATE CAD DRAWNING HANDLING ON CAD SYSTEM ONLY MODELLO MODEL TRATTAM SUPERFICIALE FLASH Microswitch NA NC C NA NC C CAPACITOR CAPACITOR ROOM FAN IGNITOR SAFETY SWITCH VACUUM SWITC...

Страница 4: ...uction EXHAUST BLOWER Silicon dust shield Faston Laminar pack Blower ROOM AIR BLOWER ROOM AIR BLOWER Blade in self cleaning steel Capacitator Revs encoder connector Rotor bell Capacitator Blower Blowe...

Страница 5: ...nector Flat cable connector 2 pole connector 2 pole connector ELECTRONIC MOTHERBOARD GEAR MOTOR Motor pack Rotor Faston electric connection Shaft Aluminium body DISPLAY FLAT CABLE Connects from displa...

Страница 6: ...res the temperature of the room where the stove is installed You are advised not to rest the probe on the floor or against the wall If possible tie the probe with the power supply cable so that it doe...

Страница 7: ...tomatic screw feeding 3 2 Modify SELECT RECEIPT 3 3 Pellet air blend setting 3 4 Rapid access menu 3 5 TIME CLEAR menu 3 6 FACTORY CALIBRATIONS menu 3 7 DATABASE menu 3 8 CLOCK SETTING menu 3 9 CHRONO...

Страница 8: ...status of the external thermostat 7 2 2 Operating procedures with external thermostat 7 3 Table of thermostat settings AIR and BOX versions 8 0 Safety Switches 8 1 Safety Device for Auger when openin...

Страница 9: ...nds after stove is switched ON the message shown in the following figure appears vER AIR Fig 1 vER BOX Fig 2 1 2 Initial conditions of a stove The starting modes of an Ecoteck stove are cold ignition...

Страница 10: ...to start as soon as possible DISPLAY SHOWING WAITING FLAME in this phase while the resistance is still working loading of the pellet continues At this time the T1 reference value for reading the smoke...

Страница 11: ...parameter pR 12 nO peLLet thReshOLD iMpORtant even if the smoke temp reaches the value set in the pR 15 the heat exchanger does not switch on until the stove goes to WORK mode this condition is neces...

Страница 12: ...se THE DISPLAY SHOWS FINAL CLEAN The switch off button is pressed the pellet loading gear motor is switched off the exhaust blower goes to maximum power and the heat exchanger runs at power 5 When the...

Страница 13: ...r34 Pr32 tempo max caricamento coclea PR33 T Lavoro Pr05 Pr02 es 7 Pt1 Pt3 Pt2 Pt impostata esempio pt3 Controllo incremento Pr34 Pr01 tempo max segnalazione MANCATA ACCENSIONE Pr31 Pr16 Pr17 Pr06 10...

Страница 14: ...the restart threshold Tsmoke PR11 and in any case over PR13 SWITCH OFF PHASE the PR 39 timer switch ON RE IGNITION BLOCK After that time the stove goes into re ignition state if the smoke temperature...

Страница 15: ...coclea PR33 T Lavoro Pr02 Pt1 Pt3 Pt2 Pt impostata esempio pt3 Controllo incremento Pr01 tempo max segnalazione MANCATA ACCENSIONE Pr31 Pr16 Pr17 Pr18 22 Pr23 27 Ventila Attesa Riavvio Max velocit Pr3...

Страница 16: ...hOOse ReCipe When first installing a stove you can modify the pellet air blend to access the ReCipe menu hold button down 4 for 3 seconds then click button 4 until you reach menu 10 seLeCt ReCipes cli...

Страница 17: ...istinguish its correct functioning To enter this menu proceed as follows 1 Keep button P4 pressed for 2 seconds CLOCK SETTING MENU will appear 2 Press button P4 4 times the display will show STOvE STA...

Страница 18: ...TION OF THE STRINGS Description Values that can be set START PROG 1 From OFF to 23 50 in 10 steps STOP PROG 1 From OFF to 23 50 in 10 steps Day PROG 1 Between on off for days from Monday to Sunday POW...

Страница 19: ...parameters in DEFAULT SETTINGS The parameter to be changed is PR42 the values change from OFF to 68 F Once the set room temperature is reached the stove as per default after about 4 minutes goes from...

Страница 20: ...completely loaded with pellets N B Remember to empty the fire pot before igniting the stove Automatic auger feeding must be carried out only when the stove is in the OFF or FINAL CLEANING status 3 2 C...

Страница 21: ...P1 and P2 to change the parameter value use keys P6 and P7 To exit the menu default settings press key P3 3 7 DATABASE MENU In processing phase 3 8 SET CLOCK menu To set the clock proceed as follows...

Страница 22: ...equipped with radio wave palm remote controls and a receiver located on the right hand side of the stove Sometimes due to interference caused by other electric devices microwave ovens satellite decode...

Страница 23: ...er the Pr35 time and can be canceled by pressing the P3 key 4 5 Pellets finished alarm This occurs if during the STABILISATION phase the smoke temperature does not reach the Pr12 value at the end of t...

Страница 24: ...PR01 PR01 PR33 PR35 ANOMALOUS FLAME ALARM if SMOKE TEMP in Ti Ti 1 with rea ding error margin PR02 PR35 PELLETS FINISHED ALARM SMOKE TEMP PR12 PR12 BLACK OUT Black out time PR38 PR38 DEPRESSION ALARM...

Страница 25: ...17 PR33 WORK 4 WORK After TIMER PR02 PR02 PR06 10 PR15 PR18 22 PR23 27 PR41 PR43 47 MODULATION 4 MODULATION WORKING if T AMB SET T AMB PR06 PR18 PR23 PR43 FIRE POT CLEANING 5 FIRE POT CLEANING With PR...

Страница 26: ...ed the value set in the PR13 theTIMER PR40 T MIN EXTINCTION is activated in order to check that the flame has gone out completely IMPORTANT the TIMER mentioned above that can be set manually by the PR...

Страница 27: ...ient probe and the ambient setting is handled by an ON OFF status of the external thermostat itself IMPORTANT Both in the AIR and the BOX versions to activate control via external thermostat connect t...

Страница 28: ...IF TEMP SET ON DISPLAY IS HIGHER THAN AMBIENT PROBE CONTROL TEMP SET ON EXTERNAL THERMOSTAT EST EXTERNAL THERMOSTAT CONNECTED CONTROL ON THE AMBIENT PROBE For BOX versions MAN EXCLUDES EXTERNAL THERMO...

Страница 29: ...pon delivery of each stove the hopper safety switch must be connected In no specific order please connect the wiring to these two prongs Fig B SPORTELLO PELLET 16 36 65 P3 wOrKing Fig A 8 2 SAFETY DEV...

Страница 30: ...ECOTECK MATRICE DI PIEGA will be legally pursued diritti a rigore di legge and must not be released to other parties without written consent any infringement in any way utilized for the manifacture of...

Страница 31: ...NON INDICATE 1 5 FCH SCALA SCALE DENOMINAZIONE DENOMINATION MATRICE DI PIEGA and must not be released to other parties without written consent any infringement in any way utilized for the manifacture...

Страница 32: ...firmware used has the extension caf firmware for I023 motherboards this will be used on all new stove models divided into air box hydro and will be programmed according to the required usage Updates t...

Страница 33: ...Brochure for models with FLASH motherboard firmware version ECT2008air ECT2008box PAGE 29...

Отзывы: