Brochure for models with FLASH motherboard
( firmware version ECT2008air - & ECT2008box - )
PAGE
18
3.10 “ChOOse LangUage“ Menu
to set the language, proceed as follows:
1. press button p7, CLOCK setting MenU will appear.
2. press button p1 2 times: the display will show LangUage seLeCtiOn MenU.
3. access with button p7. the display will show the language selected.
4. With buttons p1 and p2, select the language desired, confirm with button p7.
5. Confirming with key p7 you return automatically to the 03 ChOOse LangUage menu.
3.11 activation of the COMFORt CLiMate
COMFORt CLiMate is activated by keeping p4 pressed and adjusting a temperature delta dedicated to restart (see chapter 1.2.1
- e). another method to change the delta is to access parameters in “DeFaULt settings”. the parameter to be changed is pR 42
(values vary from OFF to 20°C).
after reaching the set room temperature, after 255’’ the stove goes from MODULe WORK to eCO stOp mode, executing a FinaL
CLean in underground. When room temperature goes below
tset amb. - delta on/off
the stove executes the phases relating to manual ignition (pressing of key p3 after “FinaL CLean”), as clearly illustrated in paragraph
6.0.
3.12 how to associate the remote control to the stove
all input stoves are equipped with radio-wave, palm remote controls and a receiver located on the right-hand side of the stove.
sometimes, due to interference caused by other electric devices (microwave ovens, satellite decoders, mobile phones, cb , .... ) the
link between the stove and the remote control is interrupted (no field).
to reinstate the connection, proceed as follows:
- switch the stove off
- unplug the power supply lead
- on the remote control, press the triangle keys 1 and 2 for about 3 seconds
- with triangle key 2, select the frequency unit to be loaded ( choose unit 0 , 1 , 2 , 3 )
- reconnect power supply by plugging in the lead
- press red key
if the operation is successful, the screen on the remote control will show Unit LOaDeD 0 , 1 , 2 , 3
4.0 aLaRMs
if an operating anomaly should occur, the motherboard intervenes and warns that an irregularity has occurred operating in various
ways depending on the type of alarm. two alarms are charted below.
alarm origin
Code
Display showing
smoke temperature probe
02
sMOKe pROBe aLaRM
smoke over-temperature
03
sMOKe OVeR-teMp. aLaRM
nO ignitiOn
05
nO ignitiOn aLaRM
Flame anomaly
11
FLaMe anOMaLY aLaRM
extinction during work phase
06
peLLets FinisheD aLaRM
Black-out
01
BLaCK - OUt
Vaccum switch
08
DepRessiOn aLaRM
general safety thermostat (on side of hopper)
07
theRMaL saFetY aLaRM
Faulty exhaust blower
04
FaULtY Fan aLaRM
exhaust blower anomaly
12
sMOKe eXtRaCtOR ReVs anOMaLY
auger blockage
-
sCReW BLOCKage aLaRM