Brochure for models with FLASH motherboard
( fi rmware version ECT2008air - & ECT2008box - )
PAGE
13
Values
pellet
From 0 to 5
to decrease the pellet load.
0
Default value that considers the set combustion as excellent
From 0 to 5
to increase the pellet load
Values
Draught
From 0 to -5
to be carried out when there is too much draught and when there is no fl ame in the fi rebox
0
Default value that considers the set combustion as excellent
From 0 to 5
to be carried out when the pellet to be used is too hard and a stronger draught is required in the combustion
chamber
n.B. a change of 5% in the parameter value corresponds to each change of value, where by “useful” parameter we mean each
value taken into consideration during the work phase: from pR06 to pR10 with regard to the “peLLet”, from pR18 to pR22
referring to the “DRaUght”
0
DRaUght
0
peLLet
2.4 Menu “state OF stOVe“
In this menu, you can check the correct functioning of the most important components of the pellet stove, and some
values which distinguish its correct functioning.
To enter this menu, proceed as follows:
1. Keep button P4 pressed for 2 seconds, CLOCK SETTING MENU will appear.
2. Press button P4 4 times: the display will show STOvE STATUS MENU
3. Access using button P6: the display will show the desired screen.
4. Confi rm with button P6 to return automatically to MENU 05 STOVE STATUS. This menu is utilized by the TAC (Technical
Assistance Center) when a problem occurs and by the customer when loading pellets into the hopper manually.
2.5 “WORKing tiMe CLeaR“ menu
in the tiMe CLeaR menu it is possible to clear the total working time of the stove. Once the menu has been selected input the
value 35 with key p5 as the access key and confi rm with key p6. “DOne” will appear on the screen confi rming the clear opera-
tion.
2.6 “DeFaULt settings” menu
to change the value of the stove parameters set by ecoteck, enter the DeFaULt settings MenU and with key p5 set value a9
as the access key and confi rm with p6. to scroll the list use keys p6 and p7, to change the parameter value use keys p4 and p5.
to exit the factory calibrations menu press key p3.
MOTOR RPM
TEMPERATURE OF SMOKE
STATE OF STOvE
2000
217°F
cOclea 0
state
STATE OF AUGER