4. INDICATOR FUNCTIONS
GRADUATION
The indication is shown in 2 lb steps.
BEFORE WEIGHING: CHECK ZERO POINT
Before each weighing it is necessary to check whether the system is unloaded and
free. The indicator is fitted with an automatic zero correction. This means that small
deviations of the zero point will be corrected automatically. If the indicator does not
determine the zero point automatically, it must be done manually using the >0< key.
GROSS WEIGHING
After lifting a load, the display shows the gross value of the weighed load.
NET WEIGHING: AUTOMATIC TARE
The indicator offers the possibility to reset tare weights to zero automatically. This
way added or subtracted weights can be determined. After taring, the graduation on
the display will not change.
Lift load.
Press the
T key.
The indicator is set to zero.
The "NET" pointer shows that a tare weight is activated.
Place or remove the net load.
The display shows the net value of the weighed load.
When removing load, this is a negative value.
By pressing the
T key again, the gross weight is displayed.