26
Parameter
Function
Settings
Default
US
35
Dataprotocol comport 2
0 = PC (bi-directional)
1 = PC Excel format on print command
2 = remote display
3 = printer with power control
4 = printer without power control
5 = not used
6 = PC excel format on print command with
ACK/NAK
7 = special 1
8 = special 2
3
36
Number of linefeeds comport
2
0-9
5
37
Handshake com2
Soft/hard
Soft
38
Print twice
0=print only once 1=Print twice
0
39
Not used
40
Level switch
NO; LS NC; LS NO; CS FA; CS RA; CS LS
NO
41
Delay trigger time level switch 0-10 sec.
3
42
Not used
43
Comp. factor cf
0.1 to 10.0 (not used)
1.0
44
Comp. factor rdx
0.1 to 10.0 (not used)
1.0
45
Comp. factor rdy
0.1 to 10.0 (not used)
1.0
46
T comp. factor zero
(not used)
1.0
47
Not used
48
T comp. factor span
(not used)
0
49
Underload % of FS
0-100 %
2
50
Peak hold time RCS
0-7
4
51
Threshold value RCS
9999 kg/lb
100.0
52
Peakhold function (RCS
function)
0= OFF 1= ON (RCS function active)
0
53-58
Not used
59
Measuring frequency
10 or 80 Hz
10
60
Battery used
12VDC
6VDC
12v
61
Low Bat switch off time
0-99 minutes
0= not switched off
2
62
Auto shut off time if not used 0-99 minutes
0= always on
30
63-64
Not used
65
Auto shut off time backlight
0; 20; 40; 80; 160; 320 seconds
20
66
Backlight brightness
100; 75; 50;20;0 %
100
67
Not used
68
Buzzer function
No/yes
No
69
Disable keys 2, 3 and 4 (only if
P16= active)
0-3
0