STORAGE
Long-Term Storage - If you will not be using the unit for an extended period of time (more than
a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the
following steps:
1.
Unplug the unit.
2.
Drain the remaining water from the unit.
3.
Clean the filter and let the filter dry completely in a shaded area.
4.
Collect the power cord at the water tank.
5.
Re-install the filter at its position.
6.
Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
7.
The unit must be kept in upright position when in storage
ATTENTION:
The evaporator inside the machine has to be dried out before the unit is packed to avoid
component damage and molds. Unplug the unit and place it in a dry open area for days to dry
it out. Another way to dry the unit is to set the humidity point more than 5% higher than the
ambient humidity to force the fan to dry the evaporator for a couple of hours.
WARNING!!!
Releasing refrigerant into atmosphere is strictly forbidden!
The symbol presented below indicates that the used equipment cannot be placed together with
other household waste. The user is obliged to bring this item to the waste electrical and
electronic equipment collection point where a suitable system is created to allow safe disposal
of these items.
Dangerous components present in electrical and electronic equipment have negative
consequences for the environment and human health therefore correct handling of the equipment is very
important. Certain substances which may adversely affect the environment over the life of the product and after
use have been limited in this device.
Product fiche
Supplier's name or trade mark
RAVANSON LTD. Sp. z o.o.
Model identifier
MAC-12000
MAC-9000
Sound power level
65
The name and GWP of the refrigerant used
R290 / 3
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP)
would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This
appliance contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of this refrigerant fluid
would be leaked to the atmosphere, the impact on global warming would be 3 times higher than 1 kg of CO2,
over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the
product yourself and always ask a professional.
Energy Efficiency Class
A
2,60 ≤ EER < 3,10
A
3,10 ≤ COP < 3,60
A
2,60
İ
EER < 3,10
A
2,30 ≤ COP < 2,60
The indicative hourly electricity consumption Q
SD
w kWh/60 min
1,357
1,020
1,010
0843
Energy consumption “X,Y” kWh per 60 minutes, based on standard test results. Actual energy consumption
will depend on how the appliance is used and where it is located.
The cooling capacity P
rated
(kW)
3,53
2,64
The heating capacity P
rated
(kW)
2,58
2,07