Instruction manual
RAVAGLIOLI S.p.A.
RAVTD1760 WS – RAVTD1780 WS
Code M0197 - rev.1.0
(11/2010)
Page 26/52
RAVAGLIOLI S.p.A. -
Via I° Maggio, n° 3 (Pontecchio Marconi)
40037 Sasso Marconi (Bologna - Italy)
Tel. 051/ 67.81.511 – Fax 051/ 84.64.67 E-mail: [email protected]
Figure 31
Turn wheel by 240° and, once the target position is reached, press detector keypad central
key, as indicated on the screen Figure 29.
The last phase consists in taking wheel back to the starting point: third point.
Once last rotation (to go back to starting position) has been carried out, programme acquires
the last measurement readings. The screen Figure 30 will be displayed again for approx.
three seconds. After measurement acquisition, programme will automatically continue, and
the following screen will be displayed:
Figure 32
On Figure 32 the front left wheel is shown with a tick on the side, to indicate that the
procedure has been carried out on that wheel. Procedure can anyway be repeated by pressing
again the central key of the concerned detector. When the Run-Out procedure has been
completed on all wheels, programme will automatically go to the next phase.
NOTE:
Watching the monitor during this procedure could sometimes prove difficult, mainly
when working on rear wheels.
To prevent this problem, the Run-Out three acquisition points can be easily
associated to the position of the 3 clamp arms (if made on 3 points) or to the 2
clamp sides with 4 points (if made on 2 points).
Position
indicator
Rotation
second
target point
Central key
flashing
Wheel on
which the
procedure has
been carried
out