Instruction manual
RAVAGLIOLI S.p.A.
RAVTD1760 WS – RAVTD1780 WS
Code M0197 - rev.1.0
(11/2010)
Page 24/52
RAVAGLIOLI S.p.A. -
Via I° Maggio, n° 3 (Pontecchio Marconi)
40037 Sasso Marconi (Bologna - Italy)
Tel. 051/ 67.81.511 – Fax 051/ 84.64.67 E-mail: [email protected]
8.5 Run-Out
The Run-Out procedure proves useful to compensate for rims and clamps unbalance. This
procedure can be skipped by pressing F4.
This procedure can be enabled also after having diagnosed the vehicle, by selecting the
special option from menu (see chap. 8.13 - Preliminary Operations).
To carry out the Run-Out procedure, you should have performed the preliminary operations,
as explained in par. 8.4.2 on page 23.
8.5.1 Run-Out with Raised Wheels
Figure 27
DETECTOR
KEYPAD
PC KEYPAD
DESCRIPTION
It goes back to Run-Out
preliminary operations
(par.8.4.2 on page23)
Make measurement
preliminary operations
(par 8.6. on page 32)
It is recommended to thoroughly comply with the displayed instructions.
During the start phase, the central keys of the displayed keypads are flashing, to indicate
which key has to be pressed to start the procedure. It is neither necessary to start from a
special wheel, nor to proceed according to a defined key order (see Figure 27).
The procedure should be carried out on all four wheels so, on the monitor, detector keypad
central keys will flash so as to suggest that you start the procedure by pressing the special
key (see Figure 27). During configuration, you can set the Run-Out procedure in 2 or 3
points. The example shows a 3-point procedure.
When keypad central key is pressed, the following screen will be displayed:
Figure 28
Position
indicator
Rotation
first target
point
Left-hand front
wheel
Left-hand rear
wheel
Right-hand rear
wheel
Right-hand
front wheel
Central keys on
detector
keypads
flashing