8

REMEDY

Replace
Replace
Check the electric installation

Wait for automatic reset
Follow instructions (Chap. 1)
Check

Replace (par. 9.3)

Replace limit switch

Replace

See para. 1.7

PROBLEM

Lift does not work

Lifting travel is not completed

Lift rises 300 mm, then heat probe 
disconnects

Irregular lifting

Mechanical block

Emergency stop

POSSIBLE CAUSE

Main safety fuses burnt out
Trasformer fuse burnt out
Power failure

Heat probe disconnected
Load exceeds rated lifting capacity
Voltage of the mains is too low

Mechanical stop due to total wear of main 
nuts

Drive belts are slipping

Limit switch damaged

Proximity switch faulty

INTERVENTO

Sostituire
Sostituire
Controllare

Attendere il riarmo
Attenersi alle norme (cap. 1)
Verifi care

Sostituire (par. 9.3)

Registrare  o sostituire

Sostituire

Vedi par. 1.7

INCONVENIENTE

Nessun funzionamento

Non completa la corsa di sollevamento

I carrelli salgono solo per 300 mm con suc-
cessivo disinserimento della sonda termica.

Corsa sollevamento irregolare

Blocco meccanico

Blocco di emergenza

CAUSA

Fusibili di protezione generale interrotti
Fusibili e trsformatore interrotto
Guasto all’impianto elettrico

Disinserimento sonda termica motore
Carico eccedente la portata nominale
Tensione rete troppo bassa

Blocco meccanico in atto per usura chiocciole 
portanti

Slittamento cinghie di trasmissione

Finecorsa danneggiato

Interruttore di prossimità danneggiato

BESEITIGUNG

Auswechseln
Auswechseln
Kontrollieren

Abwarten bis Thermosonde wieder einschaltet
Normen beachten (Kap. 1)
Nachprüfen

Auswechseln (Kap 9.3)

J

ustieren oder Auswechseln 

Auswechseln

Siehe Abschnitt 1.7

STÖRUNG

Kein Funktionieren

Aufwärtsfahrt wird nicht beendet

Hubwagen heben sich nur 300 mm, danach 
schaltet Thermosonde ab

Unregelmässige Aufwärtsbewegung

Mechanischer Stop

Not-Aus-Blockierung

URSACHE

Hauptsicherungen unterbrochen
Transformator-Sicherung unterbrochen
Störung in der Elektroanlage

Thermosonde des Motors hat abgeschaltet
Last liegt über der Nominaltragkraft
Erforderliche Spannung zu niedrig

Mechanische Sperre ist eingerastet wegen 
Abnutzung der Tragmutter

Keilriemen rutschen

Defekter Endschalter

Beschädigter Näherungsschalter

8. INCONVENIENTI

Qui di seguito sono elencati alcuni degli inconvenienti possibili durante il funzionamento del Ponte. La Ravaglioli declina ogni responsa-
bilità per danni dovuti a persone, animali e cose, per intervento da parte di personale non autorizzato. Pertanto al verifi carsi del guasto 
si raccomanda di contattare tempestivamente l’assistenza tecnica in modo da ricevere le indicazioni per poter compiere operazioni e/o 
regolazioni in condizioni di massima sicurezza, evitando il rischio di causare danni a persone, animali e cose.

E’ necessario l’intervento dell’assistenza tecnica. Vietato eseguire intervento.

Posizionare sullo "0" e lucchettare l'interruttore generale in caso di emergenza e/o manutenzione al sollevatore

Turn to 0 and padlock the main switch in case of emergency and/or maintenance to the lift

Den Hauptschalter bei Not-Aus und/oder Wartung der Hebebühnen auf “0” positionieren und verriegeln.

8. TROUBLESHOOTING

Certain problems which may arise while using the lift are listed below. Ravaglioli cannot accept any liability for injury to people or animals 
and damage to things caused by unauthorised staff using the equipment. In the event of faults, you are advised to contact the technical 
service department in good time to receive advice about how to carry out work and/or adjustments in maximum safety conditions, thus 
avoiding the risk of injury to people or animals and damage to things.

Technical service staff are required. Intervention by others prohibited.

8. BETRIEBSSTÖRUNGEN

Nachstehend einige der Betriebsstörungen, die während der Bedienung der Hebebühne auftreten könnten. Ravaglioli übernimmt in kei-
nem Fall die Haftung für eventuelle durch Eingriffe seitens nicht autorisiertem Personal verursachte Schäden an Personen, Tieren oder 
Sachen. Bei Betriebsstörungen unverzüglich den technischen Kundendienst zu Rate ziehen, damit Anweisungen zur Ausführung der 
Eingriffe und/oder Einstellungen unter Berücksichtigung der notwendigen Sicherheitsmassnahmen, damit weder für Personen, Tiere 
noch Sachen Gefahr besteht, erteilt werden können.

Muss durch den technischen Kundendienst ausgeführt werden. Eingriff verboten.

Содержание KPN250LIK

Страница 1: ...Fax 39 051 846349 e mail aftersales ravaglioli com Im Zweifelsfall oder bei R ckfragen wenden Sie sich bitte an den n chsten H ndler oder direkt an Kundendienst RAVAGLIOLI S p A Via 1 Maggio 3 40037...

Страница 2: ...ie Anleitung in einem bekannten und leicht zug nglichen Ort aufbewahren und bei Bedarf zu Rate ziehen Alle Bediener des Produktes m ssen zwecks Einsichtnahme Zugang zur Anleitung haben Alle Sch den di...

Страница 3: ...Wear work shoes Der Arbeit ange messene Schuhe tragen Mettre des chaussu res de travail Usar zapatos de trabajo Non passare n sostare sotto carichi sospesi Do not walk or stay beneath suspended loads...

Страница 4: ...IMUM REQUIREMENTS FOR THE PLACE OF INSTALLATION 6 INSTALLATION 6 1 INSTALLATION REQUIREMENTS 6 2 INSTALLATION INSTRUCTIONS 6 3 INSTALLATION OF THE ELECTRIC SYSTEM 6 4 VOLTAGE CHECK 6 5 CONNECTING UP T...

Страница 5: ...EGURIDAD 1 DISPOSITIVOS DE SEGURIDAD 1 1 INTERRUPTOR GENERAL BAJO CANDADO 1 2 SISTEMA HOMBRE MUERTO 1 3 BLOQUEO MECANICO DE EMERGENCIA 1 4 REAJUSTE DE LOS CARROS 1 5 EMERGENCIA 1 6 MANIOBRAS PERMITIDA...

Страница 6: ...atement l l vateur et liminer les causes l origine de la condition d urgence les bras doivent tre positionn s aux points pr vus par le fabricant du v hicule v rifier la stabilit du v hicule avant d en...

Страница 7: ...sus du blocage m canique ci dessus il pourrait se produire le d clenchement automatique de la sonde thermique du moteur Le r ta blissement de la sonde se fait automatiquement apr s trois minutes env...

Страница 8: ...ncarriedoutbyqualified personnel taking special care to the load position so as to avoid any unbalance between the two platforms that could affect load stability 1 7 Reset after the emergency stop Thi...

Страница 9: ...der Senkbewegung stoppt die Hebeb hne auf einer Bodenh he 13 cm Loslassen und erneut die Steuerung f r das Fortsetzen geben dabei l st sich die Sirene aus um den Bediener darauf aufmerksam zu machen...

Страница 10: ...GHETTA VOLT 400V 50Hz 3Ph TARGHETTA VOLT 230V 50Hz 3Ph TARGHETTA VOLT 220V 60Hz 3Ph TARGHETTA VOLT 380V 60Hz 3Ph TARGHETTA VOLT 400V 60Hz 3Ph PLATE PLATE PLATE PLATE PLATE PLATE PLATE PLATE PLATE PLAT...

Страница 11: ...ISQUES A T R ALIS E ET LES DANGERS ONT T LIMIN S DANS LA MESURE DU POSSIBLE LES RISQUES R SIDUELS VENTUELS ONT T SIGNAL S DANS LA PR SENTE NOTICE ET SUR LA MACHINE AU MOYEN DE PICTOGRAMMES 1 10 Pictog...

Страница 12: ...12 0471 M001 4 2 Min 1000 mm 5000 Kg 2 1 2 1...

Страница 13: ...les points d appui r versible 1 2 ou bien 2 1 r versible distance minimale entre les points de levage voie 1000 mm 2 DESTINACI N DE USO El producto est destinado a la elevaci n de autoveh culos la cap...

Страница 14: ...E DATEN Tragkraft 5000 kg Motorst rke 2 x Dreiphasenmotor 230 400V 50HZ 3 5kW Gewicht 1645 kg Ger uschpegel 70 dB A 3 CARACTERISTIQUES TECHNIQUES Capacit 5000 kg Puissance moteur 2 x moteur triphas 23...

Страница 15: ...HE DATEN Tragkraft 5000 kg Motorst rke 2 x Dreiphasenmotor 230 400V 50HZ 3 5kW Gewicht 1620 kg Ger uschpegel 70 dB A 3 CARACTERISTIQUES TECHNIQUES Capacit 5000 kg Puissance moteur 2 x moteur triphas 2...

Страница 16: ...TEN Tragkraft 5000 kg Motorst rke 2 x Dreiphasenmotor 230 400V 50HZ 3 5kW Gewicht 1645 kg Ger uschpegel 70 dB A 3 CARACTERISTIQUES TECHNIQUES Capacit 5000 kg Puissance moteur 2 x moteur triphas 230 40...

Страница 17: ...17 0471 M001 4 PAGINA LASCIATA INTENZIONALMENTE BIANCA PAGE INTENTIONELLY LEFT BLANK ABSICHTLICH LEER GELASSENE SEITE PAGE INTENTIONELLEMENT VIDE PAGINA VAC A INTENCIONADAMENTE...

Страница 18: ...18 0471 M001 4 3 A...

Страница 19: ...nstalaci n o para una nueva colocaci n hay que asegurarse de elevar con cuidado utilizando medios de soporte de la carga ade cuados en perfecto estado y los correspondientes puntos de en ganche como i...

Страница 20: ...OMMANDE 5 1 COLONNA COMANDO 2 COLONNA OPPOSTA 3 CARRELLI 4 BRACCI 5 SCATOLA COMANDO 1 CONTROL POST 2 OPPOSITE POST 3 CARRIAGES 4 ARMS 5 CONTROL BOX 1 STEUERS ULE 2 NEBENS ULE 3 HUBWAGEN 4 ARME 5 SCHAL...

Страница 21: ...tung zum Verhindern weiterer Hu bl ufe im Falle einer vollst ndigen Abnutzung einer Tragmutter Au t o m a t i s c h e S c h m i e r u n g d e r S p i n d e l n u n d Gleitschuh Gleitbahnen Automatisch...

Страница 22: ...ischen Richtlinie 98 37 CE gebaut worden Kraft des Artikels 4 1 2 3 der o g Richtlinie sind f r die Pr fungen folgende Koeffizienten angewandt worden 1 10 f r die dynamische Pr fung 1 25 f r die stati...

Страница 23: ...tung und das Arbeitsfeld berblicken kann Er muss daf r sorgen dass sich in diesem Bereich keine unbefugten Personen aufhalten oder Gegen st nde befinden die Gef hrdungen hervorrufen k nnten Alle Insta...

Страница 24: ...24 0471 M001 4 4500 6 1 3 300 Kg 3 100 000 Kgmm 2 400 000 Kgmm P Mx My 1500 2800 KPN250LIK LIKA 3000 KPN250LIKT 90 170 200 185 55 650 420 690 630 R 1 3 R 1 3...

Страница 25: ...Bodens ohne eventuelle Bodenbel ge und entsprechenden Unterbeton 15 cm c Obere und untere Bewehrung mit elektroverschwei tem Gitter 4 x 150 mm oder hnlich ausgef hrt mit Raster nicht ber 250 mm Betona...

Страница 26: ...IG N ARMADO calcestruzzo magro poor concrete Magerbeton b ton maigre hormig n pobre 105 105 105 150 Min ANCORANTE CHIMICO CHEMICAL ANCHOR CHEMISCH VERANKERT ANCRAGE CHIMIQUE ANCLAJE QU MICO 125 125 12...

Страница 27: ...hen Verankerungsmitteln HILTI HVU M16x125 oder hnlichen mit Gewindestange M16 in Stahl der Klasse 5 8 oder dar ber Die verwendeten Verankerungen m ssen eine zul ssige Minde stzugkraft von auf 1630 kg...

Страница 28: ...28 0471 M001 4 6 2 4 3 C D A B...

Страница 29: ...pas tre atteint l an crage n est pas s r V rifier l ancrage apr s avoir effectu une dizaine de courses pleinecharge encontr lantlecoupledeserrage des vis tamponn es Ce contr le doit tre effectu tous l...

Страница 30: ...30 0471 M001 4 6 5 5b C...

Страница 31: ...roduire la t te des vis dans les quatre fentes et serrer les vis de l int rieur du carter en poussant le bo tier de l installation vers le bas Fig 5 Maintenir le carter dans sa position c t de la colo...

Страница 32: ...COLLEGAMENTO TRASFORMATORE ANSCHLUSS DES TRANSFORMATORS BRANCHEMENT TRANSFORMATEUR CONEXIONES DEL TRANSFORMADOR COLLEGAMENTO MOTORE MOTOR CONNECTION MOTORANSCHLUSS BRANCHEMENT MOTEUR CONEXIONES DEL MO...

Страница 33: ...edisalireicarrelliscendono invertire2fasiall ingresso della linea sull interruttore generale Sescendeunosolodeiduecarrelli controllarel esattocollegamento nella scatola di derivazione ed eventualmente...

Страница 34: ...34 0471 M001 4 6 8 7...

Страница 35: ...ESSO GEAR OIL GX 85W 140 f llen Siehe Abschnitt 9 Die S ulenabdeckungen gem ss Abb 8 montieren Die Abdeckungen oben auf die S ulen montieren bzw die Sprossen in die entsprechenden Bohrungen einsetzen...

Страница 36: ...36 0471 M001 4 PXP PXS SMP SMS P1 L1 L2 L3 L4 L5 P2 FCS FCP RSAL RDISC CMP CMS 9A 6...

Страница 37: ...der Senkanschlag der gegen ber liegenden Steuers ule eingeschaltet siehe Position des Schlittens RSAL wenn eingeschaltet Abruf Hebebewegung RDISC wenn eingeschaltet Abruf Senkbewegung CMP eingeschalt...

Страница 38: ...38 0471 M001 4 PXP PXS SMP SMS P1 L1 L2 L3 L4 L5 P2 FCS FCP RSAL RDISC CMP CMS 9A 6...

Страница 39: ...des freizugeben P1 Freigabe des Steuers ulemotors P2 Freigabe des Motors der gegen berliegenden S ule Die Freigabe f r die S ulenbewegung muss gemeinsam mit der Senk steuerung erfolgen dazu P1 und die...

Страница 40: ...40 0471 M001 4 PXP PXS SMP SMS P1 L1 L2 L3 L4 L5 P2 FCS FCP RSAL RDISC CMP CMS 9A 6...

Страница 41: ...bis die Leds L1 L2 L3 L4 und L5 aufleuchten Nun die Senkung so weit steuern bis die Endschalter bet tigt werden berpr fen dass die Leds FCS und FCP erloschen resultieren Die Tasten P1 und P2 gleichze...

Страница 42: ...s 7 MODE D EMPLOI DU PONT ELEVATEUR 7 1 Utilisation incorrecte du pont l vateur Le pont l vateur est indiqu pour le levage des v hicules avec les caract ristiquesmentionn esaupoint Caract ristiquestec...

Страница 43: ...ren irregularidades en el funcionamiento ponerse en contacto con el servicio de asistencia del distribuidor autorizado Controlar que en la zona de trabajo alrededor de la m quina no haya objetos poten...

Страница 44: ...44 0471 M001 4 10 11 7 A A 02 1 H...

Страница 45: ...LL NOTABSENKEN Bei Stromausfall kann die Last folgendermassen auf den Boden heruntergefahren werden die Kunststoffabdeckung oben auf den S ulen abnehmen und die Spindel mit einem 17 mm Schl ssel drehe...

Страница 46: ...rastet wegen Abnutzung der Tragmutter Keilriemen rutschen Defekter Endschalter Besch digter N herungsschalter 8 INCONVENIENTI Qui di seguito sono elencati alcuni degli inconvenienti possibili durante...

Страница 47: ...LLES Nous fournissons ici la liste des pannes ventuelles susceptibles de se manifester pendant le fonctionnement du pont La Soci t RAVA GLIOLI d cline toute responsabilit en cas de dommages provoqu s...

Страница 48: ...48 0471 M001 4 a 13 12 9 14 b 2 mm max mm 10 min mm 2...

Страница 49: ...issi res des patins en les induisant d huile 9 2 Bacs de graissage Fig 13a Au moins une fois par an d monter les carters en t les et remplir le bac de lubrification en utilisant de l huile ESSO GEAR O...

Страница 50: ...n ersetzen 10 1 Verschrottung Bei endg ltiger Ausserbetriebsetzung der Einrichtung wird em pfohlen diese betriebsuntauglich zu machen Wir empfehlen alle Teile unsch dlich zu machen die Gefahren hervor...

Страница 51: ...MENTO ALIGNMENT CONTROL BOARD SA SEGNALATORE ACUSTICO CARRELLI AD ALTEZZA PERICOLOSA DANGEROUS HEIGHT SIREN RC ANTIDISTURBO BOBINA CONTATTORI CONTACTOR COLL FILTER R RESISTENZA 1 21k 1 2W RESISTANCE M...

Страница 52: ...52 0471 M001 4 PAGINA LASCIATA INTENZIONALMENTE BIANCA PAGE INTENTIONELLY LEFT BLANK ABSICHTLICH LEER GELASSENE SEITE PAGE INTENTIONELLEMENT VIDE PAGINA VAC A INTENCIONADAMENTE...

Страница 53: ...iketten die ber eine eigene Identifikationscode verf gen Pour assurer une gestion correcte des risques r siduels des pictogrammes sont appliqu s sur la machine pour signaler les zones susceptibles de...

Страница 54: ...avola Table definition Valida per i modelli Apply to models N tavola Table no Indice di modifica Cange index COLONNA COMANDO CONTROL COLUMN KPN250LIK KPN250LIKA KPN250LIKT 1A 15 10 2008 16 15 14 13 12...

Страница 55: ...a Cange index Denominazione tavola Table definition Valida per i modelli Apply to models 1B GRUPPO TRASMISSIONE TRANSMISSION ASSEMBLY KPN250LIK KPN250LIKA KPN250LIKT 15 10 2008 A A 22 21 20 19 17 16 1...

Страница 56: ...nominazione tavola Table definition Valida per i modelli Apply to models N tavola Table no Indice di modifica Cange index 1C GRUPPO FRENO BRAKE ASSEMBLY KPN250LIK KPN250LIKA KPN250LIKT 10 9 8 7 6 5 4...

Страница 57: ...vola Table no Indice di modifica Cange index Denominazione tavola Table definition Valida per i modelli Apply to models CARRELLO CARRIAGE 15 10 2008 3 KPN250LIK KPN250LIKA KPN250LIKT 12 16 9 8 7 6 5 4...

Страница 58: ...nominazione tavola Table definition Valida per i modelli Apply to models N tavola Table no Indice di modifica Cange index BRACCI ARMS KPN250LIK 4A 15 10 2008 1 2 3 4 5 6 7 8 9 10 11 12 13 14 13 15 13...

Страница 59: ...le no Indice di modifica Cange index Denominazione tavola Table definition Valida per i modelli Apply to models 4B BRACCI CORTI SHORT ARMS KPN250LIKA 15 10 2008 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...

Страница 60: ...minazione tavola Table definition Valida per i modelli Apply to models N tavola Table no Indice di modifica Cange index 4C BRACCI ARMS KPN250LIKT 15 10 2008 1 2 3 4 6 7 8 9 10 11 12 13 15 13 14 13 14...

Страница 61: ...a Table no Indice di modifica Cange index Denominazione tavola Table definition Valida per i modelli Apply to models 5 BRACCI LUNGHI LONGS ARMS KPN250LIKA 15 10 2008 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1...

Страница 62: ...4T2 2T1 21NC 3L2 1L1 5L3 6T3 RC KM1 6T3 5L3 1L1 3L2 21NC 2T1 4T2 22NC 3 5 5 3 20 20 12 12 11 11 13 14 14 13 21 21 22 22 0v 400 230 SCHERMO 0 18V FU4 18 FU3 0 24V 24 1 2 0 L1 L1 L2 L2 L3 L3 COM NO NC 1...

Страница 63: ...inazione tavola Table definition Valida per i modelli Apply to models SCHEMA MONTAG SCATOLA DERIV 400V ASSEMBLY DIAGRAM FOR 400 V CONNEC TOR BLOCK KPN250LIK KPN250LIKA KPN250LIKT 8C 15 10 2008 FCP2 FC...

Страница 64: ...efinition Valida per i modelli Apply to models N tavola Table no Indice di modifica Cange index ADESIVI E DISPOSITIVI SEGNAL DI PERICOLO TABLE FOR LABELS AND DANGER WARNING DEVICES 4 KPN250LIK KPN250L...

Страница 65: ...en Besuche seitens eines Installateurs hinweisen und bitten Sie deshalb regelm ige Kontrollen von Fachpersonal vornehmen zu lassen um letztendlich den gesetzlichen Vorschriften zu entsprechen IMPORTAN...

Страница 66: ...imento ____________________________F Tightening torque control of retention screws securing column to floor Kontrolle Anziehmoment der Arretierschrauben S ule an Fussboden Controllo corretto scorrimen...

Страница 67: ...auben S ule an Fussboden Controllo corretto scorrimento dei bracci telescopici _________________________ F F F F F Telescopic arms correct sliding control Kontrolle einwandfreies Gleiten der Teleskopa...

Страница 68: ...68 0471 M001 4 MANUTENZIONI STRAORDINARIE E RIPARAZIONI UNSCHEDULED MAINTENANCE AND REPAIRING AUSSERORDENTLICHE WARTUNGEN UND REPARATUREN 13...

Страница 69: ...al pavimento ____________________________F Contr le du couple de serrage des vis de fixation de la colonne au sol Control del par de torsi n de los tornillos de fijaci n columna en el suelo Controllo...

Страница 70: ...Controllo corretto scorrimento dei bracci telescopici _________________________ F F F F F Contr le du glissement correct des bras t lescopiques Control del correcto deslizamiento de los brazos telesc...

Страница 71: ...71 0471 M001 4 MANUTENZIONI STRAORDINARIE E RIPARAZIONI INTERVENTIONS D ENTRETIEN SPECIAL ET REPARATIONS MANTENIMIENTO EXTRAORDINARIO Y REPARACIONES 13...

Страница 72: ...das Kennschild der Ausr stung auf irgendeine Weise unbefugt zu bet tigen zu gravieren zu ver ndern oder sogar abzunehmen Das Schild nicht mit provisorischen Tafeln u s w verdecken Es muss jederzeit g...

Страница 73: ...muster Pr fungszertifikat Nr Certificat d Essai CE de type n Certificado de Examen CE de tipo n EG typgodk nnandeintyg nr 0062 150X 0170 11 00 Pontecchio Marconi 30 01 2007 RAVAGLIOLI S p A Il Diretto...

Страница 74: ...74 0471 M001 4 PAGINA LASCIATA INTENZIONALMENTE BIANCA PAGE INTENTIONELLY LEFT BLANK ABSICHTLICH LEER GELASSENE SEITE PAGE INTENTIONELLEMENT VIDE PAGINA VAC A INTENCIONADAMENTE 15...

Страница 75: ...Pr fungszertifikat Nr Certificat d Essai CE de type n Certificado de Examen CE de tipo n EG typgodk nnandeintyg nr 0062 150X 0170 11 00 EXT 04 03 06 Pontecchio Marconi 30 01 2007 RAVAGLIOLI S p A Il...

Страница 76: ...76 0471 M001 4 PAGINA LASCIATA INTENZIONALMENTE BIANCA PAGE INTENTIONELLY LEFT BLANK ABSICHTLICH LEER GELASSENE SEITE PAGE INTENTIONELLEMENT VIDE PAGINA VAC A INTENCIONADAMENTE 15...

Страница 77: ...monizadas UNI EN 292 1 Sicurezza delle macchine Parte 1 Terminologia e metodologia UNI EN 292 2 Sicurezza delle macchine Parte 2 Principi tecnici e specifiche UNI EN 1493 Sollevatori per veicoli UNI E...

Страница 78: ...78 0471 M001 4 PAGINA LASCIATA INTENZIONALMENTE BIANCA PAGE INTENTIONELLY LEFT BLANK ABSICHTLICH LEER GELASSENE SEITE PAGE INTENTIONELLEMENT VIDE PAGINA VAC A INTENCIONADAMENTE 15...

Отзывы: