46
0471-M001-4
8
REMEDY
Replace
Replace
Check the electric installation
Wait for automatic reset
Follow instructions (Chap. 1)
Check
Replace (par. 9.3)
Replace limit switch
Replace
See para. 1.7
PROBLEM
Lift does not work
Lifting travel is not completed
Lift rises 300 mm, then heat probe
disconnects
Irregular lifting
Mechanical block
Emergency stop
POSSIBLE CAUSE
Main safety fuses burnt out
Trasformer fuse burnt out
Power failure
Heat probe disconnected
Load exceeds rated lifting capacity
Voltage of the mains is too low
Mechanical stop due to total wear of main
nuts
Drive belts are slipping
Limit switch damaged
Proximity switch faulty
INTERVENTO
Sostituire
Sostituire
Controllare
Attendere il riarmo
Attenersi alle norme (cap. 1)
Verifi care
Sostituire (par. 9.3)
Registrare o sostituire
Sostituire
Vedi par. 1.7
INCONVENIENTE
Nessun funzionamento
Non completa la corsa di sollevamento
I carrelli salgono solo per 300 mm con suc-
cessivo disinserimento della sonda termica.
Corsa sollevamento irregolare
Blocco meccanico
Blocco di emergenza
CAUSA
Fusibili di protezione generale interrotti
Fusibili e trsformatore interrotto
Guasto all’impianto elettrico
Disinserimento sonda termica motore
Carico eccedente la portata nominale
Tensione rete troppo bassa
Blocco meccanico in atto per usura chiocciole
portanti
Slittamento cinghie di trasmissione
Finecorsa danneggiato
Interruttore di prossimità danneggiato
BESEITIGUNG
Auswechseln
Auswechseln
Kontrollieren
Abwarten bis Thermosonde wieder einschaltet
Normen beachten (Kap. 1)
Nachprüfen
Auswechseln (Kap 9.3)
J
ustieren oder Auswechseln
Auswechseln
Siehe Abschnitt 1.7
STÖRUNG
Kein Funktionieren
Aufwärtsfahrt wird nicht beendet
Hubwagen heben sich nur 300 mm, danach
schaltet Thermosonde ab
Unregelmässige Aufwärtsbewegung
Mechanischer Stop
Not-Aus-Blockierung
URSACHE
Hauptsicherungen unterbrochen
Transformator-Sicherung unterbrochen
Störung in der Elektroanlage
Thermosonde des Motors hat abgeschaltet
Last liegt über der Nominaltragkraft
Erforderliche Spannung zu niedrig
Mechanische Sperre ist eingerastet wegen
Abnutzung der Tragmutter
Keilriemen rutschen
Defekter Endschalter
Beschädigter Näherungsschalter
8. INCONVENIENTI
Qui di seguito sono elencati alcuni degli inconvenienti possibili durante il funzionamento del Ponte. La Ravaglioli declina ogni responsa-
bilità per danni dovuti a persone, animali e cose, per intervento da parte di personale non autorizzato. Pertanto al verifi carsi del guasto
si raccomanda di contattare tempestivamente l’assistenza tecnica in modo da ricevere le indicazioni per poter compiere operazioni e/o
regolazioni in condizioni di massima sicurezza, evitando il rischio di causare danni a persone, animali e cose.
E’ necessario l’intervento dell’assistenza tecnica. Vietato eseguire intervento.
Posizionare sullo "0" e lucchettare l'interruttore generale in caso di emergenza e/o manutenzione al sollevatore
Turn to 0 and padlock the main switch in case of emergency and/or maintenance to the lift
Den Hauptschalter bei Not-Aus und/oder Wartung der Hebebühnen auf “0” positionieren und verriegeln.
8. TROUBLESHOOTING
Certain problems which may arise while using the lift are listed below. Ravaglioli cannot accept any liability for injury to people or animals
and damage to things caused by unauthorised staff using the equipment. In the event of faults, you are advised to contact the technical
service department in good time to receive advice about how to carry out work and/or adjustments in maximum safety conditions, thus
avoiding the risk of injury to people or animals and damage to things.
Technical service staff are required. Intervention by others prohibited.
8. BETRIEBSSTÖRUNGEN
Nachstehend einige der Betriebsstörungen, die während der Bedienung der Hebebühne auftreten könnten. Ravaglioli übernimmt in kei-
nem Fall die Haftung für eventuelle durch Eingriffe seitens nicht autorisiertem Personal verursachte Schäden an Personen, Tieren oder
Sachen. Bei Betriebsstörungen unverzüglich den technischen Kundendienst zu Rate ziehen, damit Anweisungen zur Ausführung der
Eingriffe und/oder Einstellungen unter Berücksichtigung der notwendigen Sicherheitsmassnahmen, damit weder für Personen, Tiere
noch Sachen Gefahr besteht, erteilt werden können.
Muss durch den technischen Kundendienst ausgeführt werden. Eingriff verboten.
Содержание KPN250LIK
Страница 12: ...12 0471 M001 4 2 Min 1000 mm 5000 Kg 2 1 2 1...
Страница 18: ...18 0471 M001 4 3 A...
Страница 28: ...28 0471 M001 4 6 2 4 3 C D A B...
Страница 30: ...30 0471 M001 4 6 5 5b C...
Страница 34: ...34 0471 M001 4 6 8 7...
Страница 36: ...36 0471 M001 4 PXP PXS SMP SMS P1 L1 L2 L3 L4 L5 P2 FCS FCP RSAL RDISC CMP CMS 9A 6...
Страница 38: ...38 0471 M001 4 PXP PXS SMP SMS P1 L1 L2 L3 L4 L5 P2 FCS FCP RSAL RDISC CMP CMS 9A 6...
Страница 40: ...40 0471 M001 4 PXP PXS SMP SMS P1 L1 L2 L3 L4 L5 P2 FCS FCP RSAL RDISC CMP CMS 9A 6...
Страница 44: ...44 0471 M001 4 10 11 7 A A 02 1 H...
Страница 48: ...48 0471 M001 4 a 13 12 9 14 b 2 mm max mm 10 min mm 2...