Operation QUANTRON-A
63
4
AUTO km/h: Automatic operation
1.
Switch on the QUANTRON-A control unit.
2.
Open the menu
Machine settings > AUTO/MAN mode
.
3.
Highlight the
AUTO km/h
menu entry
4.
Press the
enter key
.
5.
Make the fertiliser settings:
Application rate (kg/ha)
Working width (m)
6.
Refill the hopper with fertiliser.
7.
Carry out a calibration test to determine the flow factor
or
Determine the flow factor using the provided fertiliser chart.
8.
Enter the flow factor manually.
9.
Press the
Start/Stop
key.
The spreading starts.
MAN km/h: manual operation
1.
Switch on the QUANTRON-A control unit.
2.
Open the menu
Machine settings > AUTO/MAN mode
.
3.
Highlight the
MAN km/h
menu entry.
The display shows the
Forward speed
selection window.
4.
Enter the value for the forward speed during spreading.
5.
Press the
enter key
.
NOTICE
In order to achieve optimum spreading results, you should conduct a calibration
test before beginning the spreading work.
NOTICE
In order to achieve optimum spreading results, you should conduct a calibration
test before beginning the spreading work.