Alarm messages and possible causes
103
6
6
Alarm messages and possible causes
Various alarm messages can be displayed on the QUANTRON-A control unit.
6.1
Meaning of alarm messages
No. Message on display
Meaning
Possible cause
1
Fault in dosing system. Stop! The actuator for the metering system
cannot reach the target value it is to be
moved to.
Blockage
No position feedback
2
Maximum outlet reached!
Speed or application rate
too high
Metering slider alarm
The maximum metering opening is
reached.
The set application rate (+/- quantity)
exceeds the maximum metering
opening.
3
Flow factor is outside limits.
The flow factor must lie within a range of
0.40 - 1.90
.
The newly calculated or entered flow
factor is outside the range.
4
Hopper left empty.
The left level sensor reports “empty”.
The left hopper is empty.
5
Hopper right empty.
The right level sensor reports “empty”.
The right hopper is empty.
7
Data will be deleted!
Delete = START
Cancel = ESC
Safety alarm to prevent the unintentional
deletion of data.
8
Min. quantity (150 kg) not
achieved, old factor valid.
Flow factor calculation not possible.
The application rate is too low to
calculate the new flow factor when
the residual quantity is weighed.
The old flow factor is maintained.
9
Application rate
Min. setting = 10
Max. setting = 3000
Reference to the value range of the
application rate
.
Entered value is not permitted.
10 Working width
Min. setting = 2.00
Max. setting = 50.00
Reference to the value range of the
working width
.
Entered value is not permitted.
Содержание QUANTRON-A
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 17: ...Layout and function 11 2 Figure 2 5 Control unit display MDS operating screen example 3 11...
Страница 26: ...Layout and function 2 20...
Страница 96: ...Operation QUANTRON A 4 90...
Страница 118: ...Index D...
Страница 120: ......