Update SW 
3.00.00 

 

27/08/14 
 

Chapter 411 

 

4.3 Prepare the software transmission: 

Connect the update cable to the PG and PC update interface 

 

 

4.4 Start the software transmission: 

 

 

 

Request: “

Switch on the device in the Bootstrap condition

“ 

 

Switch on the ISOBUS terminal 

 

If the display does not change, disconnect the ISOBUS connector and plug it in 
again (=> implement ECU is switched off and restarts) 

 

 

The software is transmitted => 

Transmission of the application

 

Press 
start 

Содержание AXIS-H EMC Series

Страница 1: ...Rauch Landmaschinenfabrik GmbH Landstr 14 76547 Sinzheim www rauch de english Version 2014_01 AXIS H EMC Service manual AXIS H 30 1 EMC AXIS H 30 1 EMC W AXIS H 50 1 EMC W ...

Страница 2: ... 4 Electronic system 400 Implement ECU software update 401 Update tool installation 410 AXIS H EMC SW 2 08 00 update 411 AXIS H EMC update as of SW 3 00 00 420 Metering slide calibration 430 Drop point actuator initialisation 440 Drop point actuator calibration 450 Weigh cell calibration 460 Service menu overview and description 470 Service menu machine options overview and description 471 Service...

Страница 3: ...t Diagnosis 610 Voltage supply check 620 Drop point calibration check 630 Metering slide calibration check 640 Weigh cell calibration check 650 LIN actuator check 660 Speed sensor check 670 Pressure sensor check 680 BUS communication check Chapter 7 Troubleshooting advanced settings 710 Alarm message overview 720 Idle measurement is interrupted idle measurement is not fully completed 721 As of SW ...

Страница 4: ...it diagram 811 Electric circuit diagram part 1 812 Electric circuit diagram part 2 820 Tractor installation cable circuit diagram 2054380 830 Tractor installation cable circuit diagram 2057683 831 Tractor installation cable 2057683 Individual component 2057681 832 Tractor installation cable 2057683 Individual component 2057682 833 Tractor installation cable 2057683 Ignition probing extension cable...

Страница 5: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 1 Chapter 1 Introduction ...

Страница 6: ...kshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 1 Chapter 1 Introduction 110 Preface 120 Using the manual ...

Страница 7: ... as their disposal and storage are also fundamental requirements Compliance with accident prevention regulations as well as knowledge on the prevention of accidents and hazards are required The operator must be able to independently assess risks and hazards and to take the corresponding measures In the manual hazards which cannot be assessed or hidden risks related to the product are explicitly hi...

Страница 8: ...er Completely new topics are to be included in new chapters e g 390 If existing instructions or topics are updated or extended new pieces of information are added with a consecutive number e g old chapter 390 Chapter addition 391 This manual has been prepared for practical application directly at the device and is to guide the user step by step through repairs and troubleshooting If any chapters a...

Страница 9: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 2 Chapter 2 Basic information ...

Страница 10: ...abrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 2 Chapter 2 Basic information 210 Layout and components 220 Spreader basic information 230 EMC technology basic information ...

Страница 11: ...ance of 1 100 mm between the spreading discs the AXIS H 50 1 a distance of 1 400 mm Due to the greater working widths the AXIS H 50 1 features 15 cm motors The AXIS H 30 1 features 11 cm3 motors 1 Implement ECU and cable harness Figure 1 Implement ECU behind fender Legend 1 AXIS H EMC implement ECU Teejet IC18 The implement ECU is always located behind the left hand fender R2056833 2 Cable harness...

Страница 12: ...d relay see figure 5 2056831 3 Hydraulic block complete see chapter Hydraulic system 4 Gearbox please refer to figure 2 a Gearbox left hand side without motor 4087272 b Gearbox right hand side without motor 4087273 5 Disc speed sensor 2056835 6 Pressure sensor 250 bar 2057097 7 Return flow sensor 40 bar 2057096 8 Oil motor see figure 2 a AXIS H 30 1 EMC 11 cm 3 i Left hand side 3087424 ii Right ha...

Страница 13: ...es different settings for boundary or section spreading The drop point actuators communicate with the implement ECU via a LIN BUS system The metering slides are activated depending on the application rate and forward speed mass flow rate Activation is serial the actuators feature integrated position determination Legend 1 Actuator drop point 2056487 2 Actuator metering slide 2057153 3 Load relay H...

Страница 14: ...Basic hopper volume 1200 l 1200 l 2000 l Weigh cell only hopper weight displayed x x Max capacity 3 000 kg 3 000 kg 4 000 kg Hopper size standard unit 240x130 cm 240x130 cm 290x150 cm Basic weight 340 kg 400 kg 700 kg Control ISOBUS ISOBUS ISOBUS Drive Hydraulic 45 l min at 180bar Hydraulic 45 l min at 180bar Hydraulic 65 l min at 180bar Agitator Electric 17 1 min new 11 1 min Electric 17 1 min ne...

Страница 15: ...cs Spreading disc AXIS H 30 1 EMC AXIS H 30 1 EMC W AXIS H 50 1 EMC W S2 12 18 m X X S4 18 28 m X X X S6 24 36 m X X X S8 30 42 m X X X S10 36 18 m X S12 42 50 m X VxR plus Special coating of the spreading vanes in order to increase the life time A tungsten carbide mixture is applied to the gliding surface of the spreading disc The plus indicates an increased layer thickness of the 2nd generation ...

Страница 16: ...inition EMC Electronic Mass Flow Control Mass flow control of the fertiliser on the spreading disc by means of torque measurement via pressure sensors Individual control of the slide opening for the left and right hand spreading disc Basics The proportion between pressure and mass flow is absolutely linear figure 1 This linearity is independent of the fertilizer figure 2 Figure 1 Figure 2 ...

Страница 17: ...ading disc 1 pressure sensor located at the return flow for compensating the return flow pressure From the pressure the torque and thus the mass flow can be determined From forward speed application rate and working width the target mass flow is calculated also depending on the spreading disc speed If the actual mass flow deviates from the target mass flow the position of the metering slide is rec...

Страница 18: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 3 Chapter 3 Mechanical system ...

Страница 19: ...m Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 3 Chapter 3 Mechanical system 1 Metering slide basic settings 2 drop point basic settings currently not available 3 Weigh cell and weigh frame assembly currently not available ...

Страница 20: ...metering slide Uneven application rate on the left right hand side Highly unbalanced flow factor on the left and right hand side Auxiliary equipment Lower link pins category II 28mm 1 Basic settings check Remove the spreading discs Remove the retention bolt of the actuators The metering slide can now be moved manually Open the slide completely Place the 28 mm lower link pin from the bottom or top ...

Страница 21: ...e position Correct setting Position 85 In case of deviations release the retention screws of the metering slide scale and relocate the scale in such a way that position 85 is displayed Re tighten the screws when the setting is correct Reattach the actuator bolts and secure them Reassemble the spreading discs 3 After the basic settings are changed the metering slide actuators have to be recalibrate...

Страница 22: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 4 Chapter 4 Electronic system ...

Страница 23: ... 08 00 update 411 AXIS H EMC update as of SW 3 00 00 420 Metering slide calibration 430 DP actuator initialisation 440 DP actuator calibration 450 Weigh cell calibration 460 Service menu overview and description 470 Service menu machine options overview and description 471 Service menu machine options overview and description as of SW 3 00 00 480 Control parameters and their function 481 Control p...

Страница 24: ...ble R2058068 RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 4 27 10 2014 Chapter 400 How to find the files for the update www rauch de Login for distribution partners Update cable R2058068 ...

Страница 25: ...im Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 4 27 10 2014 Chapter 400 Registration with your dealer login information If you have not obtained your dealer login information yet please send an email with your company data and customer number to o webmaster rauch de Technical documentation ...

Страница 26: ...ate with update cable R2058068 RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 3 of 4 27 10 2014 Chapter 400 AXIS Software AXIS H EMC Update The file is now ready for download ...

Страница 27: ...schinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 4 27 10 2014 Chapter 400 Unpack the zip file and save it in a folder o Here the storage location can be defined once more before the files are extracted The files can now be used ...

Страница 28: ...memory must be available d It might be necessary to deactivate the virus scan Download cable required a Update via USB interface R2058068 b Update via serial interface R2057068 For software update 2 update tools are required a PEX Loader for loading the PEX file b Teejet File Loader for loading the language packages and softkeys 1 Installation of update tools can be downloaded in the download cent...

Страница 29: ...on the PC RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 4 27 10 2014 Chapter 401 The installation is completed and an icon is created on the desktop b File loader Suggested storage location Select language ...

Страница 30: ...n of the update tool Connect the update cable to the desired interface Note If the update cable is connected to the USB port for the first time a driver is installed automatically For this an internet connection may be required a PEX Loader Open the PEX Loader by double clicking on the icon The installation is completed and an icon is created on the desktop Select the operating language Set the Ba...

Страница 31: ...547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 4 27 10 2014 Chapter 401 b File loader Open the file loader by double clicking on the icon Path of the implement ECU software Path of the implement ECU software Select the operating language Select the USB serial interface not AUTO Cancel ...

Страница 32: ...structions 2 Required accessories PC with USB port Update cable R2058068 If the cable is connected to the PC for the first time a driver is automatically installed For this an internet connection may be required PC or laptop with serial interface Update cable R2057068 The update cable is connected to the AXIS cable harness The plug has the designation PG and is normally suspended on the left hand ...

Страница 33: ...n Implement ECU connected to ISO terminal power supply established Note down the settings and calibration data example settings particularly important calibration and settings data Fertiliser settings Machine configuration Under fertilizer chart the complete spreading tables for the different fertilisers can be found As of SW 2 05 00 the spreading tables are maintained however they must be checked...

Страница 34: ... EMC W Implement ECU software update as of SW 2 08 00 Rauch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 3 of 16 Update SW 2 08 00 27 08 14 Chapter 410 Service Machine options Scales calibration Control parameters ...

Страница 35: ... Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 4 of 16 Update SW 2 08 00 27 08 14 Chapter 410 4 Implement ECU update 4 1 Open the PEX Loader 4 2 Select the file CAUTION Directory and file name may deviate from the path displayed above Press here to select the download file ...

Страница 36: ...epare the software transmission Connect the update cable to the PG and PC update interface 4 4 Start the software transmission Request Switch on the device in the Bootstrap condition Switch on the ISOBUS terminal If the display does not change disconnect the ISOBUS connector and plug it in again implement ECU is switched off and restarts The software is transmitted Transmission of the application ...

Страница 37: ... 14 Chapter 410 4 5 The end of transmission is indicated Switch off the ISOBUS terminal Disconnect the update cable from the PG update interface at the cable harness Disconnect the ISOBUS device plug and plug it in again Start the ISOBUS terminal after approx 20 seconds the spreader is loaded If the error message below appears acknowledge the error message CCI acknowledge with the button ...

Страница 38: ...softkey settings still need to be loaded 5 1 Prepare the software transmission Re connect the update cable 5 1 1 Open the Teejet File Loader The program establishes a connection to the implement ECU The connection to the implement ECU is established when the transmission buttons are highlighted In the right hand program field the available files are displayed In the left hand program field the dat...

Страница 39: ...fore the transmission of the language files and the softkset xml softkeys Just select the softkset xml and all language files in the left hand program field and press the right mouse button Delete CAUTION Do not delete the file oem_info xml Confirm the confirmation prompt with OK to delete the files 5 2 Select a path for the transmission files By pressing the key in the blue circle the file path c...

Страница 40: ...set xml file Select the desired language in the right hand program field The file ending corresponds to the country code example AXIS en The softkset xml file must be transmitted at all times As of software 3 00 00 a key assignment for the WTK joystick Rauch no 2057592 is also provided in the file aux2File dat This file contains a preconfigured key assignment for the joystick The softkset xml file...

Страница 41: ...files and the Softkset xml the files are displayed on the left hand side of the LH Loader program Check to ensure that all desired files have been transmitted Close the Teejet File Loader Switch off the terminal Disconnect the download cable and reattach the blind cap on the PG plug Re start the terminal and wait until the spreader has been registered in the terminal Deleting the object pool of th...

Страница 42: ... 3 00 00 Do not disconnect the connector wait until the spreader is reloaded The spreader is loaded with a new object pool If the spreader is not loaded automatically restart the terminal after approx 20 seconds Note The object pool may partially be deleted directly in the terminal In the terminal menu the transmitted languages may now be activated 6 After the update After the update the settings ...

Страница 43: ...ons page 1 RAUCH selection of Rauch or Kuhn logo activated after restart AXIS 50 selection of Axis 50 or Axis 30 Caution Important since there are different parameters for AXIS 50 or AXIS 30 Quantity factor 0 Actuator type RH03 Level sensor activate if mounted Weigh cell activate if mounted Machine options page 2 S N here the serial number of the spreader must be indicated SC type section control ...

Страница 44: ...ter 410 SC type DIST LENGTH calculation of the GPS switching points via distance and depth of the spreading pattern CCI terminal Müller terminal as of SW 4 xx xx TopCon SC type DIST TIME calculation of the GPS switching points via distance and 2 times John Deere terminal Müller terminal up to SW 3 96 xx Trimble system AgriTouch AgriCon AgLeader CAUTION Ask the terminal manufacturer if applicable ...

Страница 45: ... 2 08 00 27 08 14 Chapter 410 Control parameters Menu System test Service code 3354 Page 2 Control parameters Control parameters page 1 Efficiency R Efficiency L Re enter the efficiency of the motors Control parameters page 5 Velocity filter Here the forwards speed signal can be dampened 1 minimum dampening 12 maximum dampening e g for forward speed exceeding the GPS signal ...

Страница 46: ...16 Update SW 2 08 00 27 08 14 Chapter 410 Weigh cells Menu System test Service code 3354 Page 1 Calibration of weighing cells Check the calibration values and overwrite them if applicable If the weighing display is incorrect the weigh cells are to be re calibrated Fertiliser settings Re enter the fertiliser chart in the fertiliser settings menu check the settings ...

Страница 47: ...gs menu Old software only 2 03 00 Initialisation of the drop point actuators If software 2 04 10 was installed before the update the drop point actuators must be reinitialised Chapter 3 30 Drop point initialisation Last but not least After checking the settings the calibration of the actuators for metering slides and drop point as well as the calibration of the weigh cells AXIS H 30 1EMC W and AXI...

Страница 48: ...n instructions 2 Required accessories PC with USB port Update cable R2058068 If the cable is connected to the PC for the first time a driver is automatically installed For this an internet connection may be required PC or laptop with serial interface Update cable R2057068 The update cable is connected to the AXIS cable harness The plug has the designation PG and is normally suspended on the left h...

Страница 49: ...n Implement ECU connected to ISO terminal power supply established Note down the settings and calibration data example settings particularly important calibration and settings data Fertiliser settings Machine configuration Under Fertilizer chart the complete spreading tables for the different fertilisers can be found As of SW 2 05 00 the spreading tables are maintained however they must be checked...

Страница 50: ... W Implement ECU software update as of SW 3 00 00 Rauch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 3 of 16 Update SW 3 00 00 27 08 14 Chapter 411 Service Machine options weighing cells calibration Control parameters ...

Страница 51: ...auch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 4 of 16 Update SW 3 00 00 27 08 14 Chapter 411 4 Implement ECU update 4 1 Open the PEX Loader 4 2 Select the file Directory and file name may deviate from the path displayed above Press here to select the download file ...

Страница 52: ...epare the software transmission Connect the update cable to the PG and PC update interface 4 4 Start the software transmission Request Switch on the device in the Bootstrap condition Switch on the ISOBUS terminal If the display does not change disconnect the ISOBUS connector and plug it in again implement ECU is switched off and restarts The software is transmitted Transmission of the application ...

Страница 53: ... 14 Chapter 411 4 5 The end of transmission is indicated Switch off the ISOBUS terminal Disconnect the update cable from the PG update interface at the cable harness Disconnect the ISOBUS device plug and plug it in again Start the ISOBUS terminal after approx 20 seconds the spreader is loaded If the error message below appears acknowledge the error message CCI acknowledge with the button ...

Страница 54: ...softkey settings still need to be loaded 5 1 Prepare the software transmission Re connect the update cable 5 1 1 Open the Teejet File Loader The program establishes a connection to the implement ECU The connection to the implement ECU is established when the transmission buttons are highlighted In the right hand program field the available files are displayed In the left hand program field the dat...

Страница 55: ...2 Before the transmission of the language files and the softkset xml softkeys Just select the softkset xml and all language files in the left hand program field and press the right mouse button Delete Do not delete the file oem_info xml Confirm the confirmation prompt with OK to delete the files 5 2 Select a path for the transmission files By pressing the key in the blue circle the file path can b...

Страница 56: ... language in the right hand program field The file ending corresponds to the country code example AXIS de The softkset xml file must be transmitted at all times As of software 3 00 00 a key assignment for the WTK joystick Rauch no 2057592 is also provided in the file aux2File dat This file contains a preconfigured key assignment for the joystick and can also be transmitted The softkset xml file mu...

Страница 57: ...files and the Softkset xml the files are displayed on the left hand side of the LH Loader program Check to ensure that all desired files have been transmitted Close the Teejet File Loader Switch off the terminal Disconnect the download cable and reattach the blind cap on the PG plug Re start the terminal and wait until the spreader has been registered in the terminal Deleting the object pool of th...

Страница 58: ...0 00 Do not disconnect the connector wait until the spreader is reloaded The spreader is loaded with a new object pool If the spreader is not loaded automatically restart the terminal after approx 20 seconds Note The object pool may partially be deleted directly in the terminal In the terminal menu the transmitted languages may now be activated 6 After the update After the update the settings and ...

Страница 59: ...ons page 1 RAUCH selection of Rauch or Kuhn logo activated after restart AXIS 50 selection of Axis 50 or Axis 30 Caution Important since there are different parameters for AXIS 50 or AXIS 30 Quantity factor 0 Actuator type RH03 Level sensor activate if mounted Weigh cell activate if mounted Machine options page 2 S N here the serial number of the spreader must be indicated SC type section control ...

Страница 60: ... SC type DIST LENGTH calculation of the GPS switching points via distance and depth of the spreading pattern CCI terminal Müller terminal as of SW 4 xx xx TopCon SC type DIST TIME calculation of the GPS switching points via distance and 2 times John Deere terminal Müller terminal up to SW 3 96 xx Trimble system AgriTouch AgriCon AgLeader Ask the terminal manufacturer if applicable AXMAT AXMAT acti...

Страница 61: ... 3 00 00 27 08 14 Chapter 411 Control parameters Menu System test Service code 3354 Page 2 Control parameters Control parameters page 1 Efficiency R Efficiency L Re enter the efficiency of the motors Control parameters page 5 Velocity filter Here the forwards speed signal can be dampened 1 minimum dampening 12 maximum dampening e g for forward speed exceeding the GPS signal ...

Страница 62: ...15 of 16 Update SW 3 00 00 27 08 14 Chapter 411 Weigh cells Menu System test Service code 3354 Page 1 Calibrate scales Check the calibration values and overwrite them if applicable If the weighing display is incorrect the weigh cells are to be re calibrated Fertiliser settings Re enter the fertiliser chart in the fertiliser settings menu check the settings ...

Страница 63: ...gs menu Old software only 2 03 00 Initialisation of the drop point actuators If software 2 04 10 was installed before the update the drop point actuators must be reinitialised Chapter 3 30 Drop point initialisation Last but not least After checking the settings the calibration of the actuators for metering slides and drop point as well as the calibration of the weigh cell AXIS H 30 1EMC W and AXIS...

Страница 64: ...H D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 5 27 10 2014 Chapter 420 1 Metering slide actuator calibration 2 Checking the calibration 1 Metering slide actuator calibration Figures refer to AXIS H 30 1 EMC with CCI terminal Enter code 3354 ...

Страница 65: ...ns until the scale indicates a position of 0 Then confirm with OK Ensure that the actuator is not at the end stop Otherwise the carrier plate may be shifted into the long holes If the actuator can be moved under position 0 as shown in the figure the settings are correct Now move the actuator until the scale position 580 Then confirm with OK Ensure that the actuator is not at the end stop Otherwise...

Страница 66: ...f 5 27 10 2014 Chapter 420 Position 1 is not shown on the scale It is slightly under position 0 Check to ensure that the metering slide is closed completely If position 1 is calibrated too far below position 0 the slide may already open again Additionally the actuator might be at the end stop The Rauch logo may be used as point of reference Repeat this process for the left hand side ...

Страница 67: ...EMC W Metering slide actuator calibration RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 5 27 10 2014 Chapter 420 The calibration is completed ...

Страница 68: ...21 985 250 E mail service rauch de Page 5 of 5 27 10 2014 Chapter 420 2 Checking the calibration Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the metering slide settings are activated and the pre defined test points can be initiated and checked Repeat the calibration if the test points are not reached ...

Страница 69: ...meeting of the implement ECU and the actuator 1 Preparation Open the cover of the cable duct AXIS H 50 1 1 cable duct AXIS H 30 1 2 cable ducts The connector plugs of the drop point actuators are located in the cable duct the drop point actuators are equipped with white cables The designation of the connectors can be found on the machine cable Depending on the cable type the cable designation is s...

Страница 70: ... Initialisation of the drop point actuators Rauch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 2 of 3 AGP Init_de 29 08 2014 Chapter 430 2 Initialisation Figures refer to AXIS H 30 1 EMC with CCI terminal Enter code 3354 ...

Страница 71: ...nu Delete addresses Disconnect the plugs of the two actuators Then start address claiming Connect the actuator plug for the right hand side The actuator for controlling the right hand side is mounted on the spreader on the left hand side in the direction of travel Connect the actuator plug for the left hand side Initialisation successful After the initialisation the drop point actuators are to be ...

Страница 72: ...ustomer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 4 27 10 2014 Chapter 440 1 Calibration of drop point actuators 2 Checking the calibration 1 Calibration of drop point actuators AGP actuators Figures refer to AXIS H 30 1 EMC with CCI terminal Enter code 3354 ...

Страница 73: ...nfirm with OK Ensure that the actuator is not at the end stop Otherwise the setting of the mechanical levers is to be corrected If the actuator can be moved under position 0 as shown in the figure the settings are correct Now move the actuator until the scale position 9 5 Then confirm with OK Ensure that the actuator is not at the end stop Otherwise the setting of the mechanical levers is to be co...

Страница 74: ...ce information AXIS H EMC W RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 3 of 4 27 10 2014 Chapter 440 The calibration is completed ...

Страница 75: ... mail service rauch de Page 4 of 4 27 10 2014 Chapter 440 2 Checking the calibration Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the drop point settings are activated and the pre defined test points can be initiated and checked Repeat the calibration if the test points are not reached ...

Страница 76: ...er 450 1 Recalibration of weigh cells 2 Application of calibration values 3 Checking the calibration Preparation Battery voltage acceptable and or tractor is running Empty hopper Spreader horizontally installed at the tractor Weight 500kg 1 recalibration of weigh cells when replacing weigh cells recalibration Figures refer to AXIS H 30 1 EMC with CCI terminal Enter code 3354 ...

Страница 77: ...r is in a horizontal position Confirm empty weight Known quantity Upon confirmation of the empty weight the menu automatically switches over to Known quantity calibration Load the spreader with a known weight e g fertilizer front weights with known weight CAUTION Ensure that the weight is distributed equally Ensure that the spreader is in a horizontal position Enter and confirm the weight The cali...

Страница 78: ...hange of the implement ECU Figures refer to AXIS H 30 1 EMC with CCI terminal In the calibration data menu the AD values can be read and transmitted CAUTION If weigh cells are replaced recalibration is mandatory Transmit the values for calibration point 1 empty spreader and calibration point 2 known quantity Confirm the values The calibration is completed 3 Checking the calibration Figures refer t...

Страница 79: ...r is loaded with a weight e g person in the hopper the two diagnosis bars have to be approximately equal The displayed weight should correspond to the actual weight in the hopper observe tare The function can also be tested in the operating screen Under kg rest the current weight is displayed In the event of deviations between the display and the actual weight the calibration needs to be repeated ...

Страница 80: ...0 1 EMC with CCI terminal See chapter Machine options When the spreader leaves the factory all calibration values are stored in the boot menu In the event of calibration problems the factory settings can be re loaded there Please refer to the chapter Calibrate slider Please refer to the chapter Calibration of drop point Please refer to the chapter Calibration of weigh cells Please refer to the cha...

Страница 81: ...chapter Boot menu When an ISO unit is initially loaded in an ISO terminal basic unit information is stored in the terminal in order to speed up loading the next time After an update of the attachment unit or in case of problems with the display of the unit delete the object pool Device Description Object Pool All data relevant for order processing and GPS control is summarised here and can be dele...

Страница 82: ...2014 Chapter 470 As of software 2 05 00 Machine options Settings and explanations In the machine options the spreader is configured After an update the machine options need to be checked After replacement of the implement ECU the machine options need to be configured Figures refer to AXIS H 30 1 EMC with CCI terminal Here the spreader logo is changed according to the respective make ...

Страница 83: ...correction may compensate the suction effect of the spreading discs At the AXIS this suction effect does not occur due to the design of the spreading disc The value remains at 0 Currently only actuator type Römheld RH is installed in the AXIS 03 refers to the number of calibration steps If level sensors are retrofitted this field has to be checked for activation If the spreader is equipped with we...

Страница 84: ...ce rauch de Page 3 of 3 27 10 2014 Chapter 470 Input of the spreader serial number Specification for the calculation of OPTI POINT Example DIST LENGTH CCI ME SW4 08 01 TopCon DIST TIME CCI JD2600 JD2630 FM1000 AgriTouch Tellus Match FAG FAG sensor for torque measurement TC rate buf Buffering of the target quantity during EMC measurement e g for N sensors ...

Страница 85: ...Chapter 471 As of software 3 00 00 Machine options Settings and explanations In the machine options the spreader is configured After an update the machine options need to be checked After replacement of the implement ECU the machine options need to be configured Figures refer to AXIS H 30 1 EMC with CCI terminal RAUCH KUHN Here the spreader logo is changed according to the respective make ...

Страница 86: ...rection may compensate the suction effect of the spreading discs At the AXIS this suction effect does not occur due to the design of the spreading disc The value remains at 0 Actuator type Currently only actuator type Römheld RH is installed in the AXIS 03 refers to the number of calibration steps Level sensor If level sensors are retrofitted this field has to be checked for activation Weigh cells...

Страница 87: ...der serial number SC Type Specification for the calculation of OPTI POINT Example DIST LENGTH CCI ME SW4 08 01 TopCon DIST TIME JD2600 JD2630 Trimble FM1000 YARA AgriTouch Tellus Match AG Leader Integra Fendt NT01 Observe the manufacturer instructions FAG FAG sensor for torque measurement Only to be activated if FAG sensors are installed TC rate buf Buffering of the target quantity during EMC meas...

Страница 88: ... 0 7221 985 250 E mail service rauch de Page 4 of 4 27 10 2014 Chapter 471 kg level sensor As of an adjustable residual quantity in the hopper the driver receives an alarm message Hopper cover If an electrical hopper cover is installed this function can be activated here AXMAT If an AXMAT is installed it can be activated here ...

Страница 89: ...rameters Settings and explanations With the control parameters the spreader function can be set For this reason any modifications to these parameters are subject to consultation with the technical customer service and should only be implemented by specialist staff The parameters are to be checked after each update The factory parameter settings are displayed Figures refer to AXIS H 30 1 EMC with C...

Страница 90: ...or EMC factors for the individual spreading discs PWM limit value minimum control rate for proportional valve Hydraulics P Hydraulics I Control parameter for Hydraulics D proportional valve Press tolerance admissible speed variance during which EMC control is implemented Idle tolerance see above at idle measurement PWM limit value minimum control rate for proportional valve Hydraulics P Hydraulics...

Страница 91: ...S Limit admissible tolerance for AD values Overload limit V max signal voltage of the overload protection unit Deactivation time sec deactivation delay of the agitator in case of overload Actuator Min PWM minimum actuator speed Disc Max PWM limits the maximum speed of spreading discs Disc Min PWM lower speed limit of spreading discs Idle Limit1 currently not relevant Idle Limit2 currently not rele...

Страница 92: ...ol parameters Settings and explanations With the control parameters the spreader function can be set For this reason any modifications to these parameters are subject to consultation with the technical customer service and should only be implemented by specialist staff The parameters are to be checked after each update The factory parameter settings are displayed Figures refer to AXIS H 30 1 EMC w...

Страница 93: ...C factor EMC factors for the individual spreading discs PWM limit value minimum control rate for proportional valve Hydraulics P Hydraulics I Control parameter for Hydraulics D proportional valve Press tolerance admissible speed variance during which EMC control is implemented Idle tolerance see above at idle measurement PWM limit value minimum control rate for proportional valve Hydraulics P Hydr...

Страница 94: ...l voltage of the overload protection unit Deactivation time sec deactivation delay of the agitator in case of overload Actuator Min PWM minimum actuator speed Disc Max PWM limits the maximum speed of spreading discs Disc Min PWM lower speed limit of spreading discs Idle Limit1 adaptive idle measurement Adm differential value as of which the 1st idle measurement is completed Idle Limit2 adaptive id...

Страница 95: ...K Field Handle As of software version 6 11 Rauch no 2057592 This assignment is automatically loaded as default if this joystick type is connected Other joystick types The assignment of the keys must be defined refer to the operating manual of the terminal manufacturer Müller Joystick III corresponds to WTK Field Handle however cannot be loaded with default assignment Tractor specific joystick e g ...

Страница 96: ...schinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 490 Service menu page 2 By pressing Create AUX File the assignment of the joystick is saved on the implement ECU ...

Страница 97: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 04 11 2014 Chapter 5 Chapter 5 Hydraulic system ...

Страница 98: ...4 Chapter 5 Chapter 5 Hydraulic drive 510 Hydraulic block layout 511 Component drawing Hydraulic block layout 520 LS relief at the hydraulic block 530 Proportional valve venting 540 Oil motor drive unit disassembly 550 Gearbox oil change 560 Pressure sensors 561 Pressure sensor 40 bar old version 562 Pressure sensor 40 bar new version 563 Pressure sensor 250 bar ...

Страница 99: ...r left hand and right hand side 5 sealing plugs for LS relief see chapter 4 20 6 Pressure sensor 40 bar for return flow 2057358 2057358 2057090 2057890 2 Bottom view 7 Pressure scales oil motor right hand side 8 Pressure scales oil motor left hand side 9 Connection free return flow T to the tractor 22L 10 Pressure P connection to the tractor 22L 11 Return flow F1 from the oil motor right hand side...

Страница 100: ...uch de Page 2 of 3 04 11 2014 Chapter 510 4 Left hand view 16 Closure plugs for drilling channels 17 Connection P oil motor right hand side 15L 18 Connection P oil motor left hand side 15L 5 Right hand view 19 Non return valve to oil motors Safety valve to prevent incorrect direction of rotation of the oil motor and subsequent damage 2057092 16 18 17 19 ...

Страница 101: ...adjustment screw for load sensing constant current conversion 4 Sealing plugs for measurement connection 6 Pressure sensor 40bar 7 Pressure scales oil motor right hand side 8 Pressure scales oil motor left hand side 9 Connection free return flow T 10 Connection pressure P 11 Return flow from the oil motor right hand side 12 Return flow from the oil motor left hand side 13 LS signal connection 14 N...

Страница 102: ... s hydraulic system may lead to speed variations of the spreading discs Solution For hydraulic blocks delivered as of calendar week 48 2011 a relief can be created in the hydraulics block by means of screw in blinds The new blocks can be visibly identified by means of the additional closure screw labelling Upon the release of the closure screw the M6 sealing plug can be replaced by a blind Start w...

Страница 103: ...e activation of the control units or the automatic steering increases the stand by pressure to up to 50 bar o Size of the free return flow of the tractor is sufficient return flow filter is clean o LS line closed correctly in case of retrofitted power beyond solutions please check that the replacement valve has been mounted correctly o Sufficient hydraulic power o Impacts due to steering movements...

Страница 104: ...e behind the spreader or disassemble the spreading discs Preparation Drive via Load Sensing Start the tractor slightly increase the engine RPM of the tractor Drive via constant flow Start the tractor slightly increase the engine RPM of the tractor activate the control unit Venting Remove the plastic caps from the proportional valves Untighten the counter nut in counter unclockwise direction until ...

Страница 105: ...l When placing an order please ensure that the correct unit and the correct side are ordered 1 Overview of components Type AXIS H 30 1 EMC W AXIS H 50 1 EMC W Side in direction of travel left right left right Angular gearbox 4087272 4087273 4087272 4087273 Oil motor 3087424 As of 2015 3087489 3087425 As of 2015 3087490 3087368 As of 2015 3087487 3087369 As of 2015 3087488 Gear unit gearbox oil mot...

Страница 106: ... or disconnect the connector at the cable harness CAUTION During disassembly of the disc speed sensor gear oil may escape from the gearbox Disconnect the return tube and the pressure tube It may be necessary to release the clamp to disassemble the pressure tube Untighten the retention screws of the gearbox at the gearbox crossbeam and take off the gearbox downwards The gear unit can now be disasse...

Страница 107: ...CAUTION Please observe the direction of rotation of the oil motors There are left and right gear units Reattach the gearbox to the crossbeam Reconnect the hydraulic lines Prior to the installation of the disc speed sensor check the oil level in the gearbox Bottom edge of the sensor bore oil level Oil type approx 0 3 l SAE 75W 90 Perform a test run and reassemble the spreading discs ...

Страница 108: ... wear and for fertiliser deposits Otherwise the results may be incorrect Compare the quantity spread according to the trip counter with the quantity displayed by the scales Check whether the spreader is discharged unevenly No boundary spreading and no section control activated FF too low Increase efficiency FF too high Reduce efficiency Application rate too high Increase efficiency Application rat...

Страница 109: ...l level is to be checked regularly Check for oily deposits at the gearbox Prior to the oil change Working under the spreader Secure the spreader against accidental falling Take precautions against escaping oil Untighten the protective sheet under the gear unit Disassemble the disc speed sensor CAUTION During disassembly of the disc speed sensor gear oil may escape from the gearbox Untighten the di...

Страница 110: ...Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 04 11 2014 Chapter 550 Fill in the oil pump nozzle Oil type approx 0 3 l SAE 75W 90 Bottom edge of the sensor bore oil level Reassemble the disc speed sensor and the protective sheet ...

Страница 111: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 6 Chapter 6 Test Diagnosis ...

Страница 112: ... 250 E mail service rauch de Page 2 of 2 29 10 2014 Chapter 6 Chapter 6 Test Diagnosis 610 Voltage supply check 620 Drop point calibration check 630 Metering slide calibration check 640 Weigh cell calibration check 650 LIN actuator check 660 Speed sensor check 670 Pressure sensor check 680 BUS communication check ...

Страница 113: ...547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 610 Figures refer to AXIS H 30 1 EMC with CCI terminal Here the power supply of the implement ECU and the system can be checked Power voltage 60 A fuse ECU voltage 25 A fuse ...

Страница 114: ...line 49 0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 620 Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the drop point settings are activated and the pre defined test points can be initiated and checked Repeat the calibration if the test points are not reached ...

Страница 115: ...line 49 0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 630 Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the metering slide settings are activated and the pre defined test points can be initiated and checked Repeat the calibration if the test points are not reached ...

Страница 116: ... weight can be filled in for testing Please ensure that the weight is positioned in the centre of the hopper If the spreader is loaded with a weight e g person in the hopper the two diagnosis bars have to be approximately equal The displayed weight should correspond to the actual weight in the hopper observe tare The function can also be tested in the operating screen Under kg rest the current wei...

Страница 117: ...U via a bus connection The following functions are controlled via LIN actuators Drop point Hopper cover AXMAT TELIMAT AXIS M 50 1W only Figures refer to AXIS H 30 1 EMC with CCI terminal With Start self test the system checks the activated LIN BUS devices DP actuator versions 1 1 0 Index b DP actuator versions 1 0 0 old version Hopper cover not connected Note After replacement of the implement ECU...

Страница 118: ...hapter 660 Working under the spreader Switch off the tractor Secure the spreader against falling 2 Visual inspection The disc speed sensor is located at the front of the angular gearbox The sensor is equipped with a small LED The LED must blink when the spreading disc is manually rotated 3 Test Diagnosis menu Figures refer to AXIS H 30 1 EMC with CCI terminal First reset all values Reset ...

Страница 119: ...reading disc is rotated pulses must be displayed on the right hand side Test with running spreader Ensure that no one is in the danger area of the machine Tractor running active oil supply to the tractor Under PWM enter a value of approx 30 60 Start spreader discs Note Due to the tolerances of the proportional valves the speed values on the left and right hand side will not be identical Speed and ...

Страница 120: ... pressure sensors Return sensor Flow factor increase or decrease on both sides Idle measurement does not start Sensor left right Flow factor increase or decrease on one side Idle measurement does not start on one side Figures refer to AXIS H 30 1 EMC with CCI terminal As the pressure in bar is displayed with a delay the AD values of the pressure sensors are applied for testing The pressure display...

Страница 121: ...unit off Load Sensing Tractor off In idle state the AD values have a value of approx 195 Example for a sensor with short circuit AD 1023 Example for a sensor with interruption AD 0001 2 Measurement Hydraulic system activated Start the spreader disc on one side Spreading disc speed requirement The AD value on the rotating side must increase Check whether the pressure sensor is connected on the corr...

Страница 122: ...D values on the left and right side should be approximately equal Potential causes for unbalanced AD values Defective or contaminated pressure sensor High wear at the spreading discs Incorrect spreading vane mounting Defective oil motor Defective angular gearbox Average Average differential pressure Differential pressure Pressure at the spreading disc minus the return pressure Delta Pressure devia...

Страница 123: ...0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 680 In case of problems with the ISOBUS communication a hidden menu can be accessed to read out important data for programmers on internal buffers and memories For example the data can be transmitted via screen shot Hidden menu Press the button four times ...

Страница 124: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 7 Chapter 7 Troubleshooting ...

Страница 125: ...settings 710 Alarm message overview 720 Idle measurement abortion idle measurement is not fully completed 721 As of SW 3 00 00 Idle measurement is not completed 730 Flow factor increase on both sides 740 Flow factor decrease on both sides 750 Flow factor increase or decrease on one side 760 No flow factor control 770 Disc speed fluctuation 780 Actuator buzzing or pulsation 790 No drop point actuat...

Страница 126: ...ng opening is reached The set application rate appl rate exceeds the maximum metering opening 3 Flow factor lies outside acceptable limits The flow factor must lie within a range between 0 40 and 1 90 The newly calculated or entered flow factor is outside this range 4 Left hopper empty The level sensor on the left reports empty The left hand hopper is empty 5 Right hopper empty The level sensor on...

Страница 127: ...connector 21 Spreader overloaded For weighing spreader only Mineral fertiliser spreader is overstrained Too much fertiliser in the hopper 22 Unknown status Function Stop Communication problem at Terminal possible software error 27 spreading discs rotate without activation Defective or manually switched hydraulic valve 28 spreading discs could not be started spreading discs do not rotate Blockade N...

Страница 128: ... 49 0 7221 985 250 E mail service rauch de Page 3 of 3 29 10 2014 Chapter 710 34 Empty run border spread no empty run measurement can be executed spreading discs are rotating with reduced speed Empty run measurement may only be carried out if neither the border spread nor the section mode are active ...

Страница 129: ...repeatedly Disc speed is not achieved Spreading disc speed fluctuating Metering slide fluctuating buzzing actuators Idle position 1 of the metering slides is not reached or the actuator hits the end stop Pressure sensor defective on the left or right hand side Check the oil in the tractor check the LS system Check the hydraulic system of the tractor see chapter 4 Check the spreading discs for dist...

Страница 130: ...ment can be performed The temperature of the tractor hydraulic oil is too low the pressure differences are too high The spreading disc type in the fertiliser settings complies with the assembled spreading discs Run the idle measurement to heat the oil until the measurement is completed Increase the temperature of the hydraulic oil or have it heated by circulation As pressure curves are stored for ...

Страница 131: ... immediately on both sides when spreading begins Error message Flow factor outside acceptable limits Fertiliser flow factor outside of the controllable range compare fertiliser chart Switch to manual mode Return pressure sensor defective Pressure sensor return check in the Test Diagnosis menu see chapter 5 Metering slide actuators sluggish or defective Metering slide actuator check in the Test Dia...

Страница 132: ...of the controllable range compare fertiliser chart Switch to manual mode Return pressure sensor defective Pressure sensor return check in the Test Diagnosis menu see chapter 5 Metering slide actuators sluggish or defective Metering slide actuator check in the Test Diagnosis menu see chapter 5 Clogging in the outlet e g due to fertiliser remaining in the hopper for a prolonged period Low moist fert...

Страница 133: ...k in the Test Diagnosis menu see chapter 5 Clogging in the outlet e g due to fertiliser remaining in the hopper for a prolonged period Low moist fertiliser quality Empty the hopper and correct the clogging CAUTION Disconnect the machine plug at the outlet to stop the agitator prior to any cleaning attempts Check the metering slide calibration Check the spreading vanes for wear Check the spreading ...

Страница 134: ...w pulse sensor Forward speed via tractor bus system Recommendation Set the filter to 6 8 Disc speed fluctuation Disc speed is not achieved For one idle measurement the speed fluctuation must not exceed 3 of the disc speed For TWS spreaders the value can be increased to 5 To do so increase the press tolerance in the control parameters in the service menu see chapter 3 Check the hydraulic system of ...

Страница 135: ...g disc Sufficient tractor power supply voltage drop if the electric agitator is activated Sluggish agitator drive Corroded machine cable harness 2 The spreading disc speed falls or starts to fluctuate if the fertiliser comes into contact with the spreading disc LS system LS signal of the spreader too high Tractor reacts very sensitively to the LS signal Install LS blind see chapter 4 4 The spreadi...

Страница 136: ...it must be possible to rotate the piston rod manually Check the housing and cable inlet for damage Check the machine cable Check the connectors for humidity and corrosion Check the PG connection update connection for humidity and corrosion Check the connections at the implement ECU Check the implement ECU Check the contact points Check the software version Check the implement ECU for damage and in...

Страница 137: ...isplay voltage CCI terminal with the tractor installation cable R2057683 Connect a bus terminator to CAN OUT The bus terminator at the CPC plug of the cable harness must be connected Tractor installation cable R2054380 Empty tractor battery Repeat initialisation see chapter 4 DP actuators of the 1st Generation up to approx 03 2013 may lose initialisation at a slow voltage drop New generation can b...

Страница 138: ...H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 8 Chapter 8 Circuit diagrams Electrical ...

Страница 139: ... version Connection of various CCI terminal 802 Connection of various terminals to tractor ISO systems 810 Overall electric circuit diagram 811 Electric circuit diagram part 1 812 Electric circuit diagram part 2 820 Tractor installation cable circuit diagram 2054380 830 Tractor installation cable circuit diagram 2057683 831 Tractor installation cable 2057683 Individual component 2057681 832 Tracto...

Страница 140: ...ustomer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 6 29 10 2014 Chapter 800 1 AXIS H EMC with CCI Tractor installation cable 2054380 or or 2057686 Kit 4087369 2057686 2057688 2056920 AXIS H EMC Green label to distinguish from cable 2056920 Cable 1st Generation Replaced by Kit 4087369 ...

Страница 141: ...0 7221 985 250 E mail service rauch de Page 2 of 6 29 10 2014 Chapter 800 2 AXIS M ISOBUS with CCI Tractor installation cable 2054380 Kit 4087369 Cable 1st Generation Replaced by Kit 4087369 or 2057686 2057688 2056920 AXIS M ISOBUS Without the intermediate cable the spreader is not loaded Green label to distinguish from cable 2056920 ...

Страница 142: ...7221 985 250 E mail service rauch de Page 3 of 6 29 10 2014 Chapter 800 3 AXERA H EMC with QUANTRON P Tractor installation cable 2054380 2054234 198 273 For connection to the integrated bus system of Fendt tractors COM3 the cable 2057446 must be used as otherwise no communication can be established or 2057446 198 298 Label at the cable ...

Страница 143: ...ce hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 6 29 10 2014 Chapter 800 4 AXIS H EMC QUANTRON I Comfort terminal BT top Tractor installation cable 2054380 2057687 2057045 Cable 1st Generation Replaced by Kit 4120323 2057688 AXIS H EMC Kit 4120323 205768 or or Green label to distinguish from cable 2057045 ...

Страница 144: ...0 E mail service rauch de Page 5 of 6 29 10 2014 Chapter 800 5 AXIS M ISOBUS QUANTRON I Comfort terminal BT top Tractor installation cable 2054380 2057045 Cable 1st Generation Replaced by Kit 4120323 AXIS M ISOBUS 2057687 2057688 Kit 4120323 or Green label to distinguish from cable 2057045 Without the intermediate cable the spreader is not loaded ...

Страница 145: ... 7221 985 250 E mail service rauch de Page 6 of 6 29 10 2014 Chapter 800 6 AGT QUANTRON I Comfort terminal BT top Tractor installation cable 2054380 2057045 Cable 1st Generation Replaced by Kit 4120323 2057687 2057688 Kit 4120323 or Green label to distinguish from cable 2057045 Without the intermediate cable the spreader is not loaded ...

Страница 146: ...5 250 E mail service rauch de Page 1 of 3 29 10 2014 Chapter 801 1 CCI applies for all ISOBUS devices Cable harness 2057683 Bus termination 2057684 at CAN 1 OUT Bus connection 2057684 The bus termination must be connected Direct connection to CAN 1 IN If the bus termination is not connected the relays will not establish the power supply of 12V ...

Страница 147: ...r service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 3 29 10 2014 Chapter 801 2 QUANTRON I Comfort Terminal BasicTerminal Top Cable harness 2057683 2057687 2057685 15 Cable for ignition probing Via this cable the power relays are connected for a power of 12V and 12V electronics if plus is set 12V ...

Страница 148: ...9 0 7221 985 250 E mail service rauch de Page 3 of 3 29 10 2014 Chapter 801 3 AXERA H EMC with QUANTRON P Cable harness 2057683 2057685 Cable for ignition probing Via this cable the power relays are connected for a power of 12V and 12V electronics if plus is set 198 298 2057446 15 12V Label at the cable Function only with this cable ...

Страница 149: ...e rauch de Page 1 of 3 29 10 2014 Chapter 802 1 CCI In some cases the tractor bus systems still need to be configured and the CCI needs to be registered as secondary terminal Can settings uncheck priority For CCI Control and CCI Command tasks the task controller needs to be deactivated at the tractor system 2057686 Green label to distinguish from cable 2056920 ...

Страница 150: ... 29 10 2014 Chapter 802 2 QUANTRON I Comfort terminal BT top In some cases the tractor bus systems still need to be configured and the Müller terminal needs to be registered as secondary terminal as of SW 4 08 01 For Track Leader and Track Manager ISO TC tasks the task controller needs to be deactivated at the tractor system 2057687 or Green label to distinguish from cable 2057045 ...

Страница 151: ... connectors however it runs as an LBS system LBS Landwirtschaftliches Bus System preceded ISOBUS The connection can only be established to Fendt tractors or tractors whose bus system can be completely deactivated Otherwise a tractor installation cable has to be retrofitted 2054234 198 273 For connection to the integrated bus system of Fendt tractors COM3 the cable 2057446 must be used as otherwise...

Страница 152: ...ight Agitator signal Prop Valve left Pressure sensor right Pressure sensor return Pressure sensor left Connection Update Agitator power ISOBUS plug Slide left Slide right Hopper sensor left Hopper sensor right Weigh cell left Weigh cell right AGP left AGP right Disc sensor left Disc sensor right Jobcomputer Teejet ...

Страница 153: ...xis H EMC Kabelbaum mit ISO Stecker M I Prop valve Right Agitator signal Prop valve Left Pressure sensor Right Pressure sensor Return Pressure sensor Left Connection Update Agitator Power ISOBUS Plug VR RW VL PR PT PL PG MP ...

Страница 154: ...tplan Axis H EMC Kabelbaum Aktuatoren Slide left Slide right Hopper sensor left Hopper sensor right Weigh cell left Weigh cell right AGP left AGP right Disc sensor left Disc sensor right SL SR LL LR WL WR AL AR DL DR ...

Страница 155: ... 0 1 2 3 4 5 6 7 5 8 9 8 3 9 4 3 6 A B A B A B B B A B B A B C D 9 3 E A 7 A 7 A F G A F G A G H 6 A H7 A I H5 75 A G H6 0 A J F K A I G 7 L IJ F M CFD B 5 E E ...

Страница 156: ...2 1 3 71 2 7 738 738 5 9 6 7 6 2 3 0 2 23 7 9 2 8 3 8 7 2 9 6 7 2 2 37 8 5 3 5 9 5 2 8 9 8 1 2 6 6 7 5 6 3 2 2 2 2 2 2 7 37 8 2 2 2 8 5 9 6 7 2 1 2 1 1 33 8 6 3 33 23 23 23 23 4 87 2 33 33 76 17 23 2 3 4 23 9 2 8 17 1 Originaldateiname 83233162_0 pdf Artikelnummer Index Status Eingangsdatum Bearbeiter ergaenzende RAUCH Zeichnung ja nein X L2057681 _ SERIE 17 07 2013 sfritz ...

Страница 157: ...A 6 33A 0 33A 33A 33A 33A 25 33A 0 B B C B D 2 9 33A 33A 33A 25 33A C D 2 3 3 7 C D 2 7 33 4 2 2 2 4 4 4 Originaldateiname 83233162_0 pdf Artikelnummer Index Status Eingangsdatum Bearbeiter ergaenzende RAUCH Zeichnung ja nein X L2057681 _ SERIE 17 07 2013 sfritz ...

Страница 158: ... 5 2 0 2 5 2 7 7 5 2 5 7 5 8 8 52 7 4 8 5 6 7 4 4 2 4 5 7 752 7 7 2 75 2 5 7 2 4 5 2 5 2 5 4 52 6 7 4 3 4 6 75 7 2 2 9 9 4 Originaldateiname 83233133_2 pdf Artikelnummer Index Status Eingangsdatum Bearbeiter ergaenzende RAUCH Zeichnung ja nein X L2057682 _ SERIE 17 07 2013 sfritz ...

Страница 159: ...A B A0 A A 0 A B A C A B D 7 52 C B D 7 52 5 5 55 C B D 7 52 5 25 9 9 75 2 7 75 9 9 0 0 1 2 3 3 0 1 2 0 4 3 0 2 0 4 5 6789 0 4 5 0 4 5 47 0 0 678 0 1 0 1 6789 0 0 4 678 0 0 2 1 8 0 0 8 0 0 1 847 0 0 1 847 0 0 1 0 A A 9 E E 3 4 6 75 7 2 2 9 9 4 Originaldateiname 83233133_2 pdf Artikelnummer Index Status Eingangsdatum Bearbeiter ergaenzende RAUCH Zeichnung ja nein X L2057682 _ SERIE 17 07 2013 sfrit...

Страница 160: ...schaltet NC 2 Notaus_Eingang W stand 5 CAN1 L W stand 7 CAN1 H NC 1 U B Brücke 4 Notaus_Versorgung NC 6 GND NC 8 Schirm Beschreibung Ader rot U B _geschaltet 5300 50 mm Beschreibung Dieses Kabel dient als Ergänzung zum ISOBUS Traktoreinbaukabel Damit lassen sich über die Zündung geschaltete 12 V abgreifen und die Relais des Traktoreinbaukabels fallen mit dem Abschalten des Traktors ab CCI Terminal...

Страница 161: ...nenfabrik GmbH D 76547 Sinzheim Kundendienst Hotline 49 0 7221 985 250 e mail service rauch de Seite 1 von 1 03 11 2014 agitator R3087356 i 7 1 agitator R2058051 i 10 1 since Mai 2014 Pin connection Superseal Function 1 Motor 2 3 Motor 4 ...

Страница 162: ...H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 9 Chapter 9 Circuit diagrams Hydraulics ...

Страница 163: ... GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 29 10 2014 Chapter 9 Chapter 9 Hydraulic circuit diagrams 910 Hydraulic block circuit diagram 911 Hydraulic block circuit diagram with component drawing ...

Страница 164: ...rew for LS KS conversion 4 Sealing plugs for measurement connection 6 Pressure sensor 40bar 7 Pressure scales oil motor right hand side 8 Pressure scales oil motor left hand side 9 Connection free return flow T 10 Connection pressure P 11 Return flow from the oil motor right hand side 12 Return flow from the oil motor left hand side 13 LS signal connection 14 Non return valve for LS signal oil mot...

Страница 165: ...S H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 05 11 2014 Chapter 10 Chapter 10 Technical Information ...

Страница 166: ...S H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 05 11 2014 Chapter 10 Chapter 10 Technical Information ...

Страница 167: ... a standard beginning September 2014 The new cable harness order no 2058201 is installed as a standard as of May 2014 The new software V 3 00 00 with modified start up behaviour of the agitator motor will be installed as a standard beginning September 2014 Figure 1 New agitator motor Return pressure sensor The measuring diaphragm in the sensor has been modified The bursting pressure is now over 20...

Страница 168: ...on 3 01 00 is available for download in the RAUCH portal for business partners Joystick operation Operation by means of the AUX N joystick MFG 4 by WTK Elektronik is released The joystick is also available from RAUCH order no 2057592 With software version 3 01 00 the file Aux2file dat with a default key assignment for WTK AUX N joysticks as of version 6 11 is installed The key assignment can also ...

Страница 169: ... in the working screen figure 5 Figure 5 Adaptive idle measurement The time between 2 idle measurements is now calculated according to the type and speed of the spreading discs considerably reducing the number of idle measurements In case of low oil temperatures an alarm message is displayed Agitator drive The agitator drive is now switched on 3 seconds after opening the metering sliders The drive...

Страница 170: ...y Figure 7 Drop Point at deactivated sections If all sections of one side are deactivated the larger DP is now automatically set to reduce the reaction time at reactivation Figure 8 Electrical hopper cover The electrical hopper cover is controlled via LIN Bus It is activated in the machine options In the main menu the operating side figure 9 is selected with the Hopper cover soft key Figure 9 Weig...

Страница 171: ...sis The LINBUS diagnosis now displays all devices on one page The automatic check is started by Start self test Error code 0 ok Error code 2 blockage Error code 4 overload Figure 13 Available languages German English French Dutch Danish Spanish Czech Finnish Hungarian Italian Lithuanian Norwegian Polish Slovak Estonian Bulgarian Russian Swedish Russian and Bulgarian are not supported by the CCI te...

Страница 172: ...elevant machine In the past these parameters had to be requested by telephone from the RAUCH customer service Improvement Since 10 10 2014 AXIS 39602 each transmission is equipped with a label Example H EMC serial number 1631 Example M EMC serial number M0323 The label is located at the front of the relevant transmission in the direction of travel This means that in the case of service the paramet...

Страница 173: ... EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 05 11 2014 Chapter 11 Chapter 11 Terminal Compatibility list ...

Страница 174: ... EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 05 11 2014 Chapter 11 Chapter 11 Terminal compatibility list ...

Страница 175: ... Tasten Ja Ja Ja Nein Ja Nein Kverneland Tellus ISOMatch 1 8 Ja 2x6 Tasten Ja Ja Ja aber nur ein Abstand eingebbar Ja Nein Nein Fendt Varioterminal 7 Ja 2x6 Tasten Nein Nein Nein Nein Nein Nein Fendt Varioterminal 10 4 Ja 2x6 Tasten Ja Nein Ja Ja Ja Ja Trimble FmX Ja 2x6 Tasten Einschränkung in der Darstellung Nein Nein Nein Nein Nein Nein AgLeader Integra 4 5 5 4 Ja 2x6 Tasten Nein Ja Ja Nein Nei...

Отзывы: