Section
5
Check
starting
Motor
1
.
Check
.
Reverser
Not
clean
→
Clean
with
#
600
sand
paper
2
.
Ensure
.
Reverser
diameter
@
Not
conforming
to
specification
→
change
the
startig
motor
3
.
Measure
.
Mica
cut
sheet
Not
conform
to
specification
→
Scrape
the
mica
with
square
scraper
Mica
cut
sheet
:
0
.
7mm
(
0
.
028
in
)
Remark
Scrap
the
mica
with
square
scraper
to
get
proper
dimension
fit
the
reverser
.
4
.
Check
.
Armature
winding
(
insolation
/
power
on
)
Failure
→
Replce
starting
motor
**************************************
Check
procedure
of
armature
winding
.
Connnect
the
multitester
to
check
power
on
①
and
insolation
②
condition
.
Measure
the
armatur
resistance
.
If
the
resistance
is
incorrect
,
replace
the
motor
.
**************************************
Inner
resistance
of
armature
winding
Power
on
condition
check
:
At
20
℃
(
68
°
F
)
0
.
004
~
0
.
005
Ω
Insolation
check
:
At
20
℃(
68
°
F
)
ex
-
ceed
1M
Ω
-
75
-
Содержание RT150ST-A
Страница 1: ...RT150ST A SERVICE MANUAL Chongqing Rato Power Co Ltd RT150ST A...
Страница 16: ...11 Section 6 Electrical diagram of ATV...
Страница 90: ...1 Remove Cylinder head cover 2 Remove bolt shroud assy 3 Remove Spark plug 85...
Страница 91: ...5 Remove Camshaft holder 4 Remove pipe comp inlet 6 Remove Bolt Camshaft assy 86...
Страница 96: ...22 Remove Bolt Cover mission Gear Shaft drive Shaft comp counter Gear find Circlip 91...
Страница 118: ...Our group reserve the right to change structure dimension and parameter of the vehicle s parts without additional notice...