Concerning the cross section of the cables
Current consumption, recommended fuses and
cross-sections are depending also on:
•
Local prescriptions
•
Cable length & quality
•
Quality of the power supply network.
Thus they are to be adapted to local conditions.
Values shown are for a maximum cable length of 2
m. It is the responsibility of the person installing the
unit to adjust these values according to the length
of cable which will be in use.
Concerning the supply voltage
The maximum allowable tolerance of the supply volt-
age (supply voltage see name plate) is in the range
of -10% up to +10%.
Maximum dimensions of power supply cables
Maximum cable diameter (Cable gland)
Models 112
Ø Max. 25 mm
Models 211/311
Ø Max. 32 mm
Maximum cross section (For cable connection)
Units 3NAC400V, 3NAC415V, 3AC400V, 3AC440V
All models
Max. 25 mm
2
Units 3AC220V
Models 112
Max. 25 mm
2
Models 211/311
Max. 35 mm
2
Power consuption in special mode
Show-mode* Reduced
230 W
Show mode* On
115 W
Socket: Protection fuse, power available
Model 112
Country
Fuse
Available power
All
10 A
2.3 kW
Model 211 / 311
Country
Fuse
Available power
D, F
16 A
3.6 kW
CH, I
10 A
2.3 kW
GB , DK
13 A
2.9 kW
Other countries on request.
* Show-Mode, refer to the user manual!
Connection load
- 19 -
v08