For other voltages please contact the manufacturer
* Doesn't include power consumption from the embedded socket.
** Not available!
3 AC 400 V
112
112 with
vitro
211
211 with
vitro
311
311 with
vitro
Power (kW)*
13
**
26
**
42
**
Current consumption (A)
19
**
41
**
61
**
Fuse (A)
20
**
50
**
63
**
Cross section
recommended (mm²)
2,5
**
10
**
10
**
3 AC 440 V
112
112 with
vitro
211
211 with
vitro
311
311 with
vitro
Power (kW)*
16
**
22
**
35
**
Current consumption (A)
19
**
37
**
56
**
Fuse (A)
20
**
40
**
63
**
Cross section
recommended (mm²)
2,5
**
6
**
10
**
3 AC 200 V
112
112 with
vitro
211
211 with
vitro
311
311 with
vitro
Power (kW)*
17
19
28
30
45
47
Current consumption (A)
49
58
98
98
146
146
Fuse (A)
50
63
100
100
160
160
Cross section
recommended (mm²)
10
10
25
25
50
50
3 AC 220 V
112
112 with
vitro
211
211 with
vitro
311
311 with
vitro
Power (kW)*
15
17
25
26
40
42
Current consumption (A)
39
49
78
78
117
117
Fuse (A)
40
50
80
80
125
125
Cross section
recommended (mm²)
6
10
16
16
35
35
Connected loads