Before you carry out a fl ue gas analysis
check input gas fl ow pressure when burner is running
• Switch on unit. Select any mode and cooking time.
Wait till burner works
• Check input gas fl ow pressure
• See correct values of input fl ow pressure on serial plate
• If necessary adjust gas input pressure
Select „Function Test“:
• Switch on unit
• Open front panel
• Set DIP switch 1 on PCB to „ON“ position
• Select „Function Test“
Select at „FunctionTest“ the position „Gas Steam Burner“
Press key and select „Max“ rpm,
if it‘s not already selected
Activate the burner with the „Start“ key.
Note: Start key is used as a switch and will automatically
deactivate after 4 minutes
Display 4 indicates the desired CO
2
value, e.g. 9,2%,
fl ame current, i.e. 5,2μA and the corresponding rpm of the
blower motor.
Place fl ue gas testing nozzle in correct fl ue outlet
„Adjust CO
2
to given value by turning CO
2
screw on gas valve.
You also can fi nd that value on table „Values for burner adjus-
tments“
• If CO
2
value is too low => turn CO
2
screw
anti clockwise (+ direction),
• If CO
2
value is too high => turn CO
2
screw
fi rst 2 turns clockwise (- direction), and than slowly
anti clockwise (+ direction) until you get the indicated CO
2
value. (Screw adjustment tolerance).
• CO value must be below 300ppm
Press „Stop“ key. Blower will stop.
Flue gas analysis: SCC gas from 04-2004
1
2
3
4
14
-
Function
Test
Gas
Steam
Blower
Start/Stop
Max
C
O2
F
C
xxx
See
list
5,5
rpm
Flue gas analysis at MAX rpm - Cross-check of CO2 at MIN rpm
NOTE: Components are NOT protected against overload during function test!
A)
B)
C)
D)
E)
F)
G)
Содержание SCC Line
Страница 35: ...35 S S C C SCC Control Panel Notes...
Страница 41: ...41 S S C C Notes...
Страница 43: ...43 S S C C Notes...
Страница 47: ...47 S S C C Notes...
Страница 55: ...55 S S C C Notes...
Страница 63: ...63 S S C C Notes...
Страница 75: ...75 S S C C Notes The last 10 error messages can be seen in Diagnostic mode 24 Service error history...
Страница 78: ...78 S S C C M6 M6 M6 M6 S12 S12 1 2 3 4 5 6 Control Drain Valve 54 00 357 Notes...
Страница 79: ...79 S S C C Notes...
Страница 81: ...81 S S C C Notes...
Страница 91: ...91 S S C C Notes...
Страница 93: ...S 93 COMMON Notes...
Страница 107: ...S 107 COMMON Notes...
Страница 109: ...S 109 COMMON Notes...
Страница 128: ...S 128 COMMON Notes...
Страница 129: ...S 129 COMMON Notes...
Страница 183: ...S 129 COMMON Notes...