-49-
S
S
C
C
Mode: Low temperature steam;
(30-97°C (85-207°F), set temperature)
Function step
Select Wet heat
(Temp 30-97°C (85-207°F)
Select time or core temperature
Close cabinet door
Check water level inside steam
generator
Preheat steam generator,
if B5 is below 85°C (185°F);
Timer starts after successful preheating
Steam supply until set temperature in-
side cabinet is reached
Adding of Hot Air from 93°C (200°F)
possible (only 50%)
Quenching (set to 70°C/158°F)
Responsible sensor
Reed switch S3
Level electrode S2 in-
side Steam Generator
Thermocouple B5 inside
Steam Generator
Logic on PCB
Cabinet sensor B1
Cabinet sensor B1
Thermocouple B2
Signal
Door open:
12VDC X27:(1-2)
Door closed:
0VDC X27:(1-2)
X12:(1-4)
> 2VAC => no water
X12:(1-4)
~ 0VAC => water
SSR active:
12VDC X24:(1-2)+(5-6)
SSR not active: 0VDC X24:(1-2)+(5-6)
Gas unit:
Bus signal
SSR active:
12VDC X24:(1-2)+(5-6)
SSR not active: 0VDC X24:(1-2)+(5-6)
Gas unit:
Bus signal
SSR active:
12VDC X24:(7-8)+(3-4)
SSR not active: 0VDC X24:(7-8)+(3-4)
Gas unit:
Bus signal
B2 above set Temp.: Y2 active
B2 below set Temp.: Y2 not active
Remark
Solenoid Y1 energizes when no
water, 230VAC, X19:(1-4)
Heating off,
if B5 > 180°C (356°F)
Blinking dot on timer display
Decision of Hot Air supply by
PCB logic
Y2 act.:
230VAC, X19:(2-5)
Y2 not act.: 0VAC, X19:(2-5)
1
2
3
4
5
6
7
8
9
Note:
Steam heating only active when humidity fl ap (S4) is in closed position!
Below 98°C fan at lowest speed when no energy required for longer than 2 minutes.
SCC Units: Sequence of Events
Additional functions possible:
4 Fan speeds (Standard = Level 4), pulsed fan wheel,
½ Energy, HACCP output, ∆T
Содержание SCC Line
Страница 35: ...35 S S C C SCC Control Panel Notes...
Страница 41: ...41 S S C C Notes...
Страница 43: ...43 S S C C Notes...
Страница 47: ...47 S S C C Notes...
Страница 55: ...55 S S C C Notes...
Страница 63: ...63 S S C C Notes...
Страница 75: ...75 S S C C Notes The last 10 error messages can be seen in Diagnostic mode 24 Service error history...
Страница 78: ...78 S S C C M6 M6 M6 M6 S12 S12 1 2 3 4 5 6 Control Drain Valve 54 00 357 Notes...
Страница 79: ...79 S S C C Notes...
Страница 81: ...81 S S C C Notes...
Страница 91: ...91 S S C C Notes...
Страница 93: ...S 93 COMMON Notes...
Страница 107: ...S 107 COMMON Notes...
Страница 109: ...S 109 COMMON Notes...
Страница 128: ...S 128 COMMON Notes...
Страница 129: ...S 129 COMMON Notes...
Страница 183: ...S 129 COMMON Notes...