6 | Electrical connection
80.06.562_IM_2-XS_ 2-S_en-INT
35 / 56
5. Connect the protective conductor to the yellow-green terminal.
6. Connect the neutral conductor to the blue terminal.
7. Connect the grey cable directly to contactor K1.
8. Check that the wires are properly plugged in.
9. Screw in the cable gland.
10. Connect the power cable to the mains.
>>
The power connection is completed.
Colour coding of the terminals
Connection
Wire colour
Connector ter-
minal
Tool
Phase
Grey, brown or
black
L1, L2, L3
Allen key
Neutral conductor
(neutral wire)
Blue
N
Slot sccrewdriver
Protective con-
ductor
Yellow/green
PE
Slot sccrewdriver
6.5
Connect the unit to the mains for Demo mode
The Demo mode is used for demonstration purposes for the basic functions of
the unit.
Refer to the table below with the colour codes for the connection.
Colour coding of connector terminals for Demo mode
Connection
Wire colour
Connector terminal
Tool
Phase
Grey
L1
Allen key
Neutral conductor
Blue
N
Slot sccrewdriver
Protective con-
ductor
Yellow/green
PE
Slot sccrewdriver
The following functions are activated or deactivated in Demo mode:
n
Cooking processes are simulated (processes are accelerated)
n
Movement of the pan/unit cover is active
n
Heating is deactivated
If the unit is connected in Demo mode, the following connections are sufficient:
n
one phase
n
one neutral conductor
n
one protective conductor
n
Equipotential bonding
Содержание iVario 2-XS