Error message
Cause
Cooking possible
Service 20.2
Temperature probe
defective.
Yes
Service 20.4
Temperature probe
defective.
Yes
Service 20.8
Temperature probe
defective.
Only hot air mode is
available.
Service 25
The quantity of water
required by the iCareSystem
is too low.
–
Service 26
The drain valve cannot locate
the
open
position.
No
Service 27
The drain valve cannot locate
the
closed
position.
No
Service 28.1
Steam generator
temperature limit exceeded.
No
Service 28.2
Cooking cabinet temperature
limit exceeded.
No
Service 28.4
Cooking cabinet temperature
limit exceeded.
Only hot air mode is
available.
Service 29
The PCB is too hot.
No
Service 30
Humidity measurement is
malfunctioning.
Yes
Service 31.1
The core temperature probe
in the cooking cabinet is
defective.
Yes, but without the
core temperature
probe.
Service 31.2
The core temperature probe
in the cooking cabinet is
defective.
Yes, but without the
core temperature
probe.
Service 34.1
Internal data communication
malfunctioning.
No
Service 34.2
Internal data communication
malfunctioning.
No
Service 34.4
Internal data communication
malfunctioning.
No
Service 34.8
Automatic cleaning is not
functioning.
Yes