Care, inspection, maintenance and repair
16 / 107
Warning!
Inlet filter maintenance The device automatically detects if the air filter is dirty. You will receive
a service message and prompt to clean or replace the air filter when it is dirty. The appliance
may only be operated without an air filter. When replacing the air filter, please take into account
the following specifications:
Appliance size 6 x 2/3 GN, 6 x 1/1 GN, 6 x 2/1 GN, 10 x 1/1 GN
and 10 x 2/1 GN
Air filter article number 6 x 2/3 GN: 40.04.771
Air filter article number
6 x 1/1 GN, 6 x 2/1 GN, 10 x 1/1 GN, 10 x 2/1 GN: 40.03.461
This air filter may only be removed and cleaned by the user. When replacing the filter, make
sure that the air filter carefully locks into the correct position. To replace the air filter, please
follow the instructions in the "Domestic technology" section.
Appliance size 20 x 1/1 GN and 20 x 2/1 GN
This air filter may only be replaced by an authorised service partner.
Attention!
The appliance is only guaranteed protection against sprayed water if the filter and
cover are assembled correctly.
Содержание CombiMaster Plus CMP 61
Страница 1: ...CombiMaster Plus CombiMaster Original operating instructions...
Страница 65: ...Settings Celsius Fahrenheit 65 107 step info button instructions 8 Press the button to save the setting...
Страница 79: ...Cleaning CombiMaster Plus 79 107...
Страница 104: ...EU Declaration of Conformity 104 107...
Страница 105: ...EU Declaration of Conformity 105 107...
Страница 106: ...EU Declaration of Conformity 106 107...
Страница 107: ......
Страница 108: ...80 02 407 V 02 MDS Ad 09 17...