33
www.ratio-electric.com
6.3. Initial configuration of the charger
NOTICE
The
Advanced settings
menu should only be accessed by a qualified
technician. In this menu you can adjust settings that, if entered incorrectly,
could damage the installation.
Before the charger is ready for use, you need to configure the initial setup parameters:
To enter the
Advanced settings
menu, select the charger, tap the gear icon at the bottom
right corner, and select
Advanced settings
.
Note:
Entering the
Advanced settings
menu is only possible if you are within Bluetooth
®
wireless trechnology range of the charger.
Note:
It is not possible to enter the settings menu during a charging session.
Configure the following settings for the charger.
Power Sharing
configuration
If you have a single charger, leave this option Disabled.
If you have multiple chargers interconnected with data cables,
activate
Power Sharing
.
Set the charger that is directly connected to the Sensorbox to:
Main Controller
Available options: Disabled, MAIN, SUB1, SUB2, SUB3.
Note:
Make sure every sub charger is set to a unique SUB number.
Note:
Make sure only one of the interconnected chargers is set to “Main Controller”.
Note:
PureSolar mode is not compatible with
Power Sharing
. If you enable
Power Sharing
,
the charge mode will be set to SmartSolar.
Home connection
maximum current
Set this value to the size of the grid connection as measured by the
CT clamps. E.g. if the home has a 3× 25A connection, set this value
to 25A. This value is used for
Dynamic Load Balancing
.
Charger connection
maximum current
Set the maximum allowed charging power of the charger.
Range: 6A – 32A.
Note:
This value must be lower than the rating of the used MCB.
Number of solar
power phases
Select the amount of phases on which the solar panel installation
is installed.
Note
: This value is only used when the charge mode is set to PureSolar or SmartSolar.