Configure the following settings for the charger.
CHG MODE
Select the desired charge mode.
Available options: Basic, Smart, Smart Solar, Pure Solar.
Default: Basic.
Note:
Pure Solar mode is not compatible with power sharing. If you set the charge mode to
Pure Solar, power sharing will be disabled.
Note:
See chapter 2 for more information on the charge modes.
POWER
SHARING
If you have a single charger, leave this option Disabled.
If you have multiple chargers interconnected with data cables, activate
power sharing.
Set the charger that is directly connected to the sensorbox to: Main
Controller
Available options: Disabled, MAIN, SUB1, SUB2, SUB3.
Default: Disabled.
Note:
Make sure every sub charger is set to a unique SUB number.
Note:
Make sure only one of the interconnected chargers is set to “Main Controller”.
Note:
Pure Solar mode is not compatible with power sharing. If you enable power sharing,
the charge mode will be set to Smart Solar.
I-MIN
Set the minimum required charging power of the charger.
Range: 5A - 16A.
Default: 6A.
I-MAX
Set the maximum allowed charging power of the charger.
Range: 7A – 32A.
Default: 16 or 32A, depending on the charger model.
I-MAX HOME
Set the maximum available power consumption of the main grid. This
value is important for Load Balancing and/or dynamic charging.
Range: 10A – 99A.
Note:
This option is only used in SMART and SOLAR mode, or when the power sharing
option has been set to Main Controller for this charger.
I-MAX Sys
Set the maximum available power consumption of the main grid. This
value is important for Load Balancing and/or dynamic charging.
Range: 10A – 99A.