background image

73

Update your iX3M 2

Is very important to keep your iX3M 2 always up-to-date.

Subscribe the “Update alerts” service for free following the instruction in the next page.

The iX3M 2 can be connected with the USB cable to a Pc or to a Mac in order to update the device.

 

 

To connect the iX3M 2 to a 

Windows PC

Mac, or Linux PC 

follow step-by-step the tutorial available here: 

http://www.ratio-computers.com/support

Attention: 

During the update a new OS version will replace the old OS version.

 

 

After an update always:

 

- Check that your dive settings are the one you need for your next dive (mixes, algorithm settings etc.)

 

- Consider that you will need to calibrate the compass. (see page COMPASS of this manual)

 

- Consider that after an update the iX3M 2 can“Reset to Default” (see “RESET TO DEFAULT” of this manual)

 

- Consider to perform a complete recharge of your iX3M 2 (not mandatory but suggested)

Содержание iX3M 2 Deep

Страница 1: ...1 iX3M 2 User Manual Warning This manual is valid only for iX3M 2 updated to OS 5 1 5 6 016 or above ver 6 03...

Страница 2: ...installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communicatio...

Страница 3: ...end a message writing iX3M 2 to the following address update ratio computers com This service is highly recommended and it is completely free of charge For further support have a look at the tutorial...

Страница 4: ...organization The dive computer is an auxiliary instrument to the dive it is compulsory having always an appropriate training and backup in order to carry out the decompression phase in case the devic...

Страница 5: ...5 Think Green If possible do not print this manual Use your tablet or your PC to consult it...

Страница 6: ...part of the display 24 Bottom part of the display 25 iX3M 2 Menu 26 MAIN MENU 27 DIVE SET 1 28 DIVE SET 1 for RATIO iX3M 2 Pro and iX3M 2 Deep 29 DIVE SET 1 for RATIO iX3M 2 Tech 31 DIVE SET 2 32 Deco...

Страница 7: ...Connect your iX3M 2 to a PC or a Mac 73 Update your iX3M 2 51 iX3M 2 after a Tissue Reset 52 TRANSMITTERS 53 Compass settings COMPASS 54 Model serial number and operative system 54 SWITCH OFF Manual s...

Страница 8: ...en toxicity and other risks relating to the diving itself Even a careful reading of this manual and the use of this device won t prevent possible dangers Anyone who doesn t know or doesn t accept cons...

Страница 9: ...h Never share a unique computer for two divers while diving every diver must have his her device at his her wrist which can give information to him her only Never dive with a computer which has not ta...

Страница 10: ...d clearly Check always that settings are the ones desired Don t let the computer be manipulated by someone else before diving In this case check that settings are the ones you desire Consider that our...

Страница 11: ...d be longer than the one visualised according to some parameters calculated by the computer during the whole dive Trying to ascend at the correct speed and respect the visualized depth of the stops he...

Страница 12: ...e training Passing the PPO2 set and advised maximum limit imposes an ascent at minor depths and in case the CNS CSELECTl Nervous System has values very close to the maximum limit a reduction to O2 exp...

Страница 13: ...computer to chemical agents alcohol included To clean the computer use exclusively fresh water removing all salt sediments Let the computer dry naturally without using cold or warm air jets Do not exp...

Страница 14: ...dirt or chlorine could cause the malfunctioning of the buttons The RATIO iX3M 2 computer is designed to be waterproof in sea and fresh water but at the end of every dive it must be well rinsed in fres...

Страница 15: ...y and intuitive access to all settings Weight 260gr Sensor s precision warranty 130 mt 426 ft Maximum Depth 300 mt 984 ft Absolute Pressure Measure precision min max p 0 5bar 20 mbar 20 mbar p 0 10bar...

Страница 16: ...tegration Yes up to 3 Transmitters optional Yes up to 3 Transmitters optional Yes up to 10 Transmitters optional MultiTransmitter Side Mount Yes up to 2 Transmitters optional Yes up to 3 Transmitters...

Страница 17: ...hange of 15 depending on the environmental temperature the device settings the installed applications the operative system version the back light setting and the use of its inner Bluetooth or external...

Страница 18: ...finished the symbol will disappear Once the battery charge is finished even if the device remains connected to the plug the computer automatically interrupts the electricity flow In case the device is...

Страница 19: ...and the precision of the sensor When diving in cold or freezing waters the battery voltage may decrease more rapidly than normal So we recommend to recharge the battery before diving in extreme condi...

Страница 20: ...fields relating to the program DAN DSL Diving Safety Laboratory inside the Divelogger export them in the format DAN DL7 and send them by e mail to dsl daneurope org Give your diving profiles to the Re...

Страница 21: ...ivity After diving the RATIO iX3M 2 activates the Sleep mode modality after 10 minutes of inactivity it switches the screen off and deactivates all processes which are not useful for the post diving d...

Страница 22: ...battery Model name position top center Is possible to replace RATIO with your name Connect your iX3M 2 to Ratio ToolBox to edit this part of the display The Ratio ToolBox is available on the support a...

Страница 23: ...f the MIX 1 as set in the MIX TABLE menu AIR 21 00 EAN XX es 32 00 TX O2 He The MIX value blinks in Red Yellow if the set MIX can not be used as surface MIX MAIN SYSTEM COMPASS DIVE READY TO DIVE AIR...

Страница 24: ...e when the iX3M 2 is performing the SELF TEST CALIBRATION IN PROGRESS iX3M 2 is performing an automatic recalibration of the pressure sensor Do not dive when the iX3M 2 is performing the calibration L...

Страница 25: ...ALT GF OC 93 93 12 00 01 01 2022 TU TECH RATIO 100 BACK ENTER UP DOWN MAIN MENU DIVE SETS 1 DIVE SETS 2 MIX TABLE DECO STOP APP MENU PLANNER LOGBOOK ALLARMS SET OC MIX GASES 21 1 DEPTH RUNTIME NDL PPO...

Страница 26: ...odel some entries might not be visualized Helpful tip You can change the RATIO iX3M 2 s menu color titles and data from the menu DISPLAY b A C D EXIT Select UP DOWN A MAIN SYSTEM COMPASS DIVE READY TO...

Страница 27: ...er dive it is NOT possible to set the FREE mode as main mode if at least 12 hours have passed from your last SCUBA GAUGE or CCR dive The RATIO iX3M 2 sets automatically the SCUBA mode if trying to for...

Страница 28: ...conservatism will make the device makes its calculation in a more precautionary way Generally speaking it is recommended to increase the conservatism if you feel an excessive tiredness after your las...

Страница 29: ...rapidly ATTENTION To change the Gradient Factor s value a suitable theoretical knowledge is needed DO NOT CHANGETHE GRADIENT FACTORSWITHOUT A SUITABLETRAINING The RATIO iX3M 2 is not responsible for d...

Страница 30: ...e for damages to people or objects due to a wrong setting of such parameters For suggested protection levels refer to the previous pages of this manual Helpful tip If you have any doubts on your devic...

Страница 31: ...Safety Stop timer is re set if the depth of 9mt 60ft is passed again The Safety Stop is automatically omitted if one or more mandatory deco stops have to be performed when the diver ascent to 10mt 30f...

Страница 32: ...mt will be spaced out of 3 mt while the stops between 15 mt and the surface will be spaced out of 3 mt Helpful tip To force the last stop to a preset depth eg 6mt you can set STEP1 6mt and DEPTH1 6mt...

Страница 33: ...andfromSETPOINTMIDto SETPOINTLOWatDEPTH1 MAN The Set Point have to be managed manually during the dive See Change the set point during a dive on this manual During the dive you can switch from AUTO to...

Страница 34: ...you have not received the specific training do not change the MIX settings and do not dive with EAN or Trimix Set mixes are considered in the decompression calculations Do not set mixes that are diffe...

Страница 35: ...ximum depth to which the mix created can be used The MOD is re calculated automatically every time the MIX or the PPO2 value are changed It is not possible to change the MOD directly During the dive a...

Страница 36: ...used The MOD is re calculated automatically every time the MIX or the PPO2 value are changed It is not possible to change the MOD directly EAD Equivalent Air Depth Attention Enable the Rebreather mod...

Страница 37: ...ENTER UP DOWN APP MENU MIX ANALYZER GAS BLENDER BACK ENTER UP DOWN APP MENU MIX ANALYZER GAS BLENDER b A C D EXIT NEXT UP DOWN mix analyser o2 CALIBRATE DEV FW 0 00 SET TO MIX 1 BACK SET GAS BLENDER M...

Страница 38: ...has to be decided by the diver If you are not sure about the EAN safety approximation to be set for your dive ask your diving instructor or your diving certification agency Plug the Gas mix connector...

Страница 39: ...decided by the diver If you are not sure about the EAN safety approximation to be set for your dive ask your diving instructor or your diving certification agency mix analyser o2 CALIBRATE DEV FW 0 0...

Страница 40: ...mathematic calculation based on the data inserted by the user Refer always to specialized centers and to qualified personnel to fill your tanks up Be always sure that your tanks are inspected and resp...

Страница 41: ...D buttons pressed to modify the iX3M 2 values more quickly START MIX O2 He The Mix of Oxygen and Helium in percentage inside the tank at the moment START P Bar The pressure expressed in Bar inside th...

Страница 42: ...dd Oxygen in the tank until you reach151 4 Bar of pressure inside the tank TOP UP WITH AIR Add Air 21 00 inside the tank until you reach the final desired pressure 200 bar as in the example Do you kno...

Страница 43: ...disappears If the dive is within the safety parameters NDL Remaining non decompression time after the time you have set CNS of accumulated CNS OTU of accumulated OTU MIX QTY Mix value expressed in li...

Страница 44: ...top MIX It indicates the mix used to calculate the decompression to be set in menu MIX Press D to pass to the next screen to visualize CNS e OTU ATTENTION the planner uses 18 mt min 60ft min as descen...

Страница 45: ...vents happened before the dive in the logbook The special records are identified by a number following this legenda 1 A tissue reset has been performed before the dive 2 An user settings reset has bee...

Страница 46: ...of ascending too fast MOD Itactivates deactivatesthealarmincaseofpassingtheMODofthemixyouarecurrentlybreathing GAS RES iX3M 2 activates the alarm when the pressure of the main tank is below the RES va...

Страница 47: ...r RATIO iX3M 2 model some entries might not be visualized Helpful tip You can change the RATIO iX3M 2 menu headlines and data colors from the menu DISPLAY A b C D MAIN SYSTEM COMPASS DIVE READY TO DIV...

Страница 48: ...data color LABEL Dive parameters labels color TITLE the Menu headlines color ITEM the different menu s parameters color SEL the color of the selected menu entry Helpful tip If you have any doubts on y...

Страница 49: ...ets the time format 24hr o 12hr DATE It sets the date UNITS it sets the metric or imperial unit of measure PC Mode connecttoaPC Mac Linux To connect the iX3M 2 to the PC Mac Linux install the Ratio To...

Страница 50: ...ulation EXECUTE It carries out the reset of the entries set as YES WARNING DANGER DO NOT reset the tissue saturation TISSUES YES if the device will be always used by the same person This may cause the...

Страница 51: ...he device The device have to be used only by a person who has not carried out dives during the previous 48 hours You can ignore the message if you have NOT carried out any dive during the previous 48...

Страница 52: ...n handle up to 10 transmitters The iX3M 2 Deep can handle up to 3 transmitters The iX3M 2 Pro can handle up to 3 transmitters The RATIO CCTransmitter dedicated manual how to pair how to use etc is ava...

Страница 53: ...t the compass Direction and Declination on https en wikipedia org wiki Magnetic_declination CALIBRATE Calibrate the compass see pictures below BACK NEXT COMPASS SETTINGS DECLINATION 0 0 DIRECTION EAST...

Страница 54: ...g off The RATIO iX3M 2 switches off automatically after a certain inactivity period However you can also switch the device off manually If the device is in charge the command will be executed only onc...

Страница 55: ...tions Direction in route 5 in comparison with the one set with D It indicates the direction to follow to find the route you have set Reciprocal direction 5 in comparison with the set reciprocal route...

Страница 56: ...d start the dive It is suggested to turn ON the iX3M 2 before juming in the water COMPASS SETTINGS ADDITIONAL DATA A b C D OC MIX MAX 50 DEPTH RUNTIME NDL PPO2 21 0 86 12 5 2 m 00 45 2 m DEPTH RUNTIME...

Страница 57: ...e your depth to reach the next DECO Stop depth Right DECO Stop depth the sign of the STOP is blinking Increase your depth to back to the correct DECO stop depth OC MIX MAX 50 DEPTH RUNTIME NDL PPO2 21...

Страница 58: ...mmended the Deep Stop information are shown at the place of STOP and TIME data The Deep Stop is not mandatory and in case it is omitted even after having set it it does not affect on the iX3M 2 decomp...

Страница 59: ...SES is intended to be used to check how many mixes are active before the dive GASES is hid during the dive Press D button to display TEMP Current water temperature ASC Ascent or descent speed expresse...

Страница 60: ...algorithms BUL or VPM The yellow lines represent the nitrogen levels The green lines represent the helium levels if present The blue line represents the environment pressure in the surface at the dive...

Страница 61: ...ive Stop the iX3M 2 shows The possible Safety Stop and Deep Stop since they are not mandatory are not shown in the Decompressive Chart even if they will be suggested to the diver during the dive DEPTH...

Страница 62: ...pass on centre Graphic compass with route indication Direction in route 5 from the one set with D Direction to follow to find the route initially set right or left Direction in reciprocal 5 from the r...

Страница 63: ...if you REFUSE the mix change the suggested mix will be DISABLED iX3M 2 assumes that you will not be able to use the suggested mix during the dive You can reactivate the mix in the MIX TABLE see follo...

Страница 64: ...e each alarm individually Press and hold A to mute the first alarm than press and hold A to mute the second alarm A A A CONFIRM PRESS AND HOLD 3 SEC CONFIRM PRESS AND HOLD 3 SEC OC MIX MAX 50 DEPTH RU...

Страница 65: ...Ton this manual DIVE SETS 2 edit the Safety Stop Deep Stop end Last Stop settings SeeDIVESETS2 on this manual For iX3M 2 Tech only if CCR MODE DILUENT TABLE edit the diluent table see DILUENT TABLE on...

Страница 66: ...iX3M2 Tech only Switch between Open Circuit mode OC and Closed Circuit Mode CCR and viceversa Press to save and exit Attention in the following pages we will explain how to modify the MIX and the algo...

Страница 67: ...0 DEPTH RUNTIME NDL PPO2 21 0 86 12 5 2 m 00 45 2 m OC MIX MAX 50 DEPTH RUNTIME NDL PPO2 21 0 86 12 5 2 m 00 45 2 m OC MIX MAX 50 DEPTH RUNTIME NDL PPO2 21 0 86 12 5 2 m 00 45 2 m OC MIX MAX 50 DEPTH...

Страница 68: ...Helpful tip Reduce the algorithm conservatism is particularly useful to handle possible emergencies during the dive If for any reason you have not enough gas for the ascent it is possible to decrease...

Страница 69: ...n this manual Attention Enable the Rebreather mode CCR only for dives with rebreather The CCR mode is not suitable for dives in open circuit Attention Diving with Rebreather requires a specific traini...

Страница 70: ...press D AVG is highlighted in green then press B Do your know what The iX3M 2 calculates in background the tissue saturation and desaturation also in GAUGE mode using a fake Mix 10 60 with a high ine...

Страница 71: ...after decompression dives The above is for sports diving and should not apply to commercial diving Because of the complex nature of DCS there can never be a fixed flying after diving rule that can gua...

Страница 72: ...a Pc or to a Mac in order to download the dive data and to update the device To connect the iX3M 2 to a Windows PC Mac or Linux PC follow step by step the tutorial available here http www ratio comput...

Страница 73: ...tep the tutorial available here http www ratio computers com support Attention During the update a new OS version will replace the old OS version After an update always Check that your dive settings a...

Страница 74: ...se send a message writing iX3M 2 to the following address update ratio computers com This service is highly recommended and it is completely free of charge For further support have a look at the tutor...

Страница 75: ...75 2022 The reproduction even partial without stated approval is severely prohibited RATIO Computers...

Отзывы: