Installation & Operating Manual /DISC-O-FLEX/RLM,RLMK
RATHI TRANSPOWER PVT.LTD. Gaia Apex,S No 33/2D,Viman Nagar
R-II-D-03/02-09/20
Pune, 411014
Page 4
of 15
3.2.4
Straight bore with interference fit.
Check appropriate fit between shaft and hub bore.
Place the key over the shaft slotted area.
Heat the hub in oil bath up to temperature 150° C to make bore bigger than shaft.
Immediately slide expanded hub over the shaft up to desired position.(Fig. 3)
Tighten the set screw with torque wrench.
3.2.5
Taper Bore (Fig.5)
Slid the hub over the shaft without inserting key up to DBSE as required.
Mark the hub position onto the shaft, or mount the dial indicator by keeping in
contact with hub flange.
Remove the hub and insert key(s) in the shaft.
Heat the hub in oil bath up to temperature 150° C to make bore bigger than shaft.
Immediately slide expanded hub over the shaft up to marked position.
Tighten the set screw with torque wrench.
Fig. 5 Taper bore