Page 4
Testing the IP Interface
1.
Plug analog telephone into Phone 1 port on the 2100-VOIP2CS.
2.
If the test call is successful, the unit is ready for operation.
3.
Unplug analog phone from Phone 1 port then connect the RATH
®
2100 Series Analog Phone or Area of Refuge.
Reset Button
To reset all information entered into the 2100-VOIP2CS, unplug the Ethernet cable from the Ethernet port then press
and hold the red reset button for 20 seconds. THIS WILL DEFAULT THE UNIT TO DHCP (you will no longer be able
to log into the device using 192.168.1.160). The 2100-VOIP2CS will have to be connected to a network capable of
DHC. Plug Ethernet cable back into the Ethernet port on the 2100-VOIP2CS then to log back into the unit. Perform
one of the following steps:
1.
Set the Network Interface Card of the PC to
“Obtain an IP Address Automatically”
(see Step 4 under IP
Interface Set-Up above). Use a network scanner loaded onto the PC to search for the device on the network (name
of device will display as SPA112 or SPA191). The network scanner should display the address the unit it now using.
2.
Plug an analog telephone into the Phone 1 port on the 2100-VOIP2CS.
a. Lift the handset on the analog phone and dial
*, *, *, *
b. Dial
110
then
#
(phone will state IP address of unit)
c. Dial
120
then
#
for Subnet Mask
d. Dial
130
then
#
for Gateway
e. Hang up analog phone
8
. After unit reboots, follow instructions in Step 4 to change IP Address of Computer to an address in the same net
work scheme as 2100-VOIP2CS.
9.
Log back into IP Interface using IP Address assigned to the unit in Step 7
10.
Click on
VOICE
under the menu options on the top of the screen
11
. Under Line 1 Status, verify next to Registration State unit shows
Registered
. If unit shows Registered, it is ready
for use. If unit shows Not Registered please verify SIP information or see Troubleshooting Section.