background image

Ratek OM8 Orbital Shaker – User Manual 

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

 

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

Page 12 of 15

 

 

Cleaning The Orbital Shaker 

 

 

 

CAUTION 

Do not use alcohol based cleaners or solvents on the Orbital Shaker as these may break down certain components of it’s 
construction, reducing it’s life and potentially creating a hazardous situation. Use only a mild household detergent when cleaning 
the Orbital Shaker. 

 

 

 

CAUTION 

If the Orbital Shaker has been used with any dangerous, chemical or biological substances it should be decontaminated prior to 
cleaning. Decontaminate the Orbital Shaker using a decontamination procedure appropriate to the contaminant, however in all 
cases ensure the following : 
 

-

 

No decontamination or cleaning agents are used which could cause a hazardous situation to arise as a result of a 
reaction with parts of the Orbital Shaker or with any materials contained in it. For example, substances that may 
compromise the integrity or function of electrical insulation, electrical components or other components. 

 

-

 

Ratek are consulted prior to decontamination or cleaning being undertaken if there is any doubt about the compatibility 
of decontamination or cleaning agents with parts of the Orbital Shaker or with any materials contained in it.  

 

 

 

 

CAUTION 

When cleaning the unit, only use a damp sponge. 

Do not use a sodden wet sponge.

 Do not make any part of the control panel, 

any exposed control or receptacle or any part of the Orbital Shaker excessively wet. If these receptacles and controls remain wet 
once electrical power is restored they can create a hazardous situation sufficient to cause serious injury or risk to life due to 
electrical shock.  Always ensure the unit and in particular all controls and receptacles are completely dry before restoring 
electrical power. 
 

 

-

 

Unplug the equipment from the mains power supply outlet. 

 

-

 

Allow the Orbital Shaker to air dry, or use a dry cloth to remove water from all surfaces. 

 

-

 

Using a mild detergent and damp sponge, clean around the platform and the top of the machine as well as the control panel, 
ensuring no water is allowed to get behind any switches. 

 

-

 

Wipe the underside of the rubber feet to ensure the mixer will remain securely in place during operation. 

 

-

 

Once the Orbital Shaker is clean, use a soft dry cloth to dry all surfaces of the mixer paying particular attention to any 
controls or receptacles. 

 

-

 

Once cleaning has been completed, it may be re-installed and operated in accordance with this User Manual. 

 

 

Maintenance

 

 

 

 

-

 

Unplug the equipment from the mains power supply outlet. 

 

-

 

Under good light, carefully inspect the mains power lead and check for any signs of wear, over-extension or damage. If you 
believe the lead to be damaged in any way, contact your supplier. 

  

-

 

Carefully check to ensure all safety warning labels are affixed and in a good readable condition. Refer to the section in this User 
Manual titled “Safety Labels & Markings” for a table of factory-fitted warning labels. If any labels are missing, illegible or 
otherwise not functional, contact your supplier to obtain new replacement labels before operating the equipment. 

 

-

 

Ensure all controls and switches are good condition. If any are found to be loose or not operating correctly, have an authorized 
service technician repair the unit before operating it. 

 

 

 

 

CAUTION 

If any controls or switches are found to be loose or in poor condition, do not operate the equipment. Loose or damaged electrical 
controls and connections may create a hazardous situation sufficient to cause serious injury or risk to life. Refer the equipment to 
an authorized service technician for repair.  

Содержание OM8

Страница 1: ...015 English www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made in Australia User Manual printed in Australia...

Страница 2: ...the product to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the product into the supplied...

Страница 3: ...TY CONSIDERATIONS 5 5 5 5 Conditions of Operation 5 Safety Labels And Markings 6 OPERATING PROCEDURES 6 6 6 6 Identification of Controls Functions 6 Safety Warnings 7 Safety Recommendations 7 Preparat...

Страница 4: ...r the Operator Any item that is not suitably secured to the mixing platform Suitable Environments For The Orbital Shaker The Orbital Shaker is intended for use in a clean laboratory environment only w...

Страница 5: ...ng in how to perform their work safely in accordance with any local operational health and safety regulations The operator and all users should be well versed in local emergency procedures as per the...

Страница 6: ...as a rotating platform which should not be touched whilst it is moving Keep all body parts away from the moving platform whilst in operation Always stop the platform using the front panel speed contro...

Страница 7: ...kplace administrator or electrical maintenance staff to determine if a protective earth power socket is available A surge protected power outlet is strongly recommended as it provides some protection...

Страница 8: ...inimum unobstructed distance of 500 millimetres in front of the Orbital Shaker to allow adequate room for the user to maintain a safe operating distance of 300 millimetres CAUTION The Orbital Shaker i...

Страница 9: ...erly rated protective earthed wall mounted power supply outlet If there are double adapters or oversized DC power packs causing obstruction of the mains power lead plug these should first be removed E...

Страница 10: ...weight The counterweight is located beneath the platform carrier It is adjustable and has 4 positions The counterweight should be set for the expected load to enable the shaker to operate smoothly wit...

Страница 11: ...overed bars The bars can be moved horizontally enabling flasks test tube racks and most other types of containers to be secured to the platform TCT25 Tulip Clip Tray This tray is suitable for holding...

Страница 12: ...d receptacles are completely dry before restoring electrical power Unplug the equipment from the mains power supply outlet Allow the Orbital Shaker to air dry or use a dry cloth to remove water from a...

Страница 13: ...etres Temperature 0 Celsius to 45 Celsius Maximum relative humidity 80 for temperatures up to 31 Celsius decreasing linearly to 50 relative humidity at 40 Celsius MAINS supply voltage fluctuations up...

Страница 14: ...a 3 year parts and 12 months labour return to base warranty effective from the date of purchase The product is manufactured in Melbourne Australia The warranty is offered by Ratek Instruments Pty Ltd...

Страница 15: ...refund Ratek Instruments will pay your reasonable direct expenses of claiming under this Warranty You may submit details and proof of your expense claim to Ratek Instruments for consideration This Wa...

Отзывы: