8
In the Dry mode, the air conditioner will generally operate in the form of a dehumidifier.
Since the conditioned space is a closed or sealed area, some degree of cooling will
continue.
O
O
The temperature setting are adjustable between 17 C to 30 C .
O
O
The temperature setting are adjustable between 17 C to 30 C .
The unit will select the appropriate operating mode from Fan, Cool or Heat based upon the
temperature difference between the actual and desired room temperature. If the actual room
O
temperature is 2 C above the set point, the unit operates in cooling mode. When the actual
O
O
room temperature is 1 C higher above the set point but 2 C lower below the set point, the
O
unit will select the Fan mode. When the actual room temperature is 2 C below the set point,
the unit will operate in Heat mode.
Note :
If activating the SLEEP mode when the unit is operating on AUTO mode, the fan motor will changed into
LOW speed mode immediately.
ECONOMY(SLEEP):
For the models with SWING feaure, press and hold the "ECONOMY" keypad for 2 seconds
or use the remote control to activate the "ECONOMY" feature.
Press and hold the "SWING" keypadfor 2 seconds again or use the remote control again
to deactivate the "ECONOMY(SLEEP)" feature. For units without "SWING" feature, use
the remote control to activate the "ECONOMY(SLEEP)" feature.
O
In the Cooling mode, the cooling temperature set point will increase 1 C per hour after the
"ECONOMY(SLEEP)" mode is selected. Two hours later , the set point will continue at this
temperature and the fan motor will remain on LOW speed.
O
In the Heating mode, the heating temperature set point will decrease 1 C per hour after the
"
ECONOMY(SLEEP)" mode is selected. Two hours later, the set point will continue at this
temperature and the fan motor will remain on LOW speed.
Using the "ECONOMY(SLEEP)" mode will reduce noise creating a comfortable sleeping
environment.
Note :
This feature is not available under DRY and FAN ONLY operation.