background image

22

Safety Precautions

To prevent personal injury, injury to others or property 
damage, please comply with the following: 
Incorrect operation due to failure to follow instructions 
below may cause harm or damage, the seriousness of 
which is classi

fi

 ed as below:

This appliances is not intended for accessibility by the 
general public.

WARNING

This sign warns of death 
or serious injury.

CAUTION

This sign warns of injury 
or damage to property.

The instructions to be followed are classi

fi

 ed by the 

following symbols:

This symbol denotes an action that 
is PROHIBITED.

These symbols denote actions 
COMPULSORY.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air inlet

Air inlet

Air outlet

Air outlet

Air outlet

Air outlet

  

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they 

have been given supervision or instruction 

concerning use of the appliance by a person 

responsible for their safety. Children should be 

supervised to ensure that they do not play with 

the appliance.
Please consult an authorised dealer or 

specialist to clean the internal parts, repair, 

install, remove, disassemble and reinstall the 

unit. Improper installation and handling will

cause leakage, electric shock or 

fi

 re.

Con

fi

 rm with authorised dealer or specialist on 

usage of any speci

fi

 ed refrigerant type. Using 

refrigerant type other than the speci

fi

 ed may 

cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting 

process or to clean, other than those 

recommended by manufacturer.

Any un

fi

 t method or using incompatible material 

may cause product damage, burst and serious 

injury.
Do not install the unit in a potentially explosive 

or 

fl

 ammable atmosphere. 

Failure to do so could result in 

fi

 re.

Do not insert your 

fi

 ngers or other 

objects into the air conditioner indoor 

or outdoor unit, rotating parts may 

cause injury.
Do not touch the outdoor unit during lightning, it 

may cause electric shock.
Do not expose yourself directly to cold air for a 

long period to avoid excess cooling.
Do not sit or step on the unit, you may 

fall down accidentally.

Remote control

Do not allow infants and small children to play 

with the remote control to prevent them from 

accidentally swallowing the batteries.

Содержание CS-LZ9ZKA

Страница 1: ...ler should Read the Installation Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit If the equipment is transferred to a new us...

Страница 2: ...R03 3 8 A 1 5 12 am pm 24 2 ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO AIR CONDITIONER ON OFF TIMER CANCEL AIR SWING SLEEP FAN SPEED QUIET POWERFUL EC...

Страница 3: ...3 B 2 DRY AUTO HEAT COOL 1 POWER ON 3 TEMP UP TEMP DOWN 16 0 C 30 0 C 60 F 86 F 10 C F 4 11 12 13 14 15 16 18 19 AAA R03 2 2 Panasonic...

Страница 4: ...4...

Страница 5: ...5 ON Ni Cd ELCB RCD ELCB BS...

Страница 6: ...6 nanoe G R32 Amin m Amin m A R32 R410A R22 R32 R22 R32 R22 R32 R410A R32 R410A R32 R410A R22 R32 R410A 1 2 R32 R410A AHU a b c d...

Страница 7: ...7 e f g h i j 5 0 25 1 04 MPa 4 15 MPa 1 A Amin m 12 2 2 1 2 2 2 2 2 8 2 2...

Страница 8: ...8 2 3 2 4 CO2 2 5 2 6 2 7 2 8...

Страница 9: ...9 6 7 5 1 04 MPa 4 15 MPa 0 25 LFL 25 8 3 4 5...

Страница 10: ...10 10 a b c d e f g h 80 i j k 11 8 OFN OFN OFN OFN 9 OFN 7...

Страница 11: ...11 12...

Страница 12: ...E SLEEP FAN SPEED QUIET POWERFUL ECO AIR CONDITIONER ON OFF POWER TIMER nanoe TECHNOLOGY FAN SPEED QUIET FAN SPEED AUTO FAN QUIET FAN SPEED QUIET POWERFUL 20 ECO POWERFUL ECO POWERFUL ECO nanoe X nano...

Страница 13: ...EP POWERFUL ECO FAN SPEED QUIET POWERFUL ECO POWERFUL QUIET FAN SPEED 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h SLEEP ON OFF SET TIMER CANCEL 1 2 3 1 TIMER ON TIMER OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF...

Страница 14: ...0 C 24 0 C 68 F 75 F COOL 26 0 C 28 0 C 79 F 82 F COOL DRY HEAT AUTO COOL HEAT DRY nanoe X 2 5 3 C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 46 114 8 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 HEAT 30 86 0...

Страница 15: ...15 H 99 pH 7 40 C 104 F nanoeTM G 2 2 nanoe G AUTO OFF ON 1 2 2 AUTO OFF ON 1 3 4...

Страница 16: ...16 POWER TIMER ON 30 TIMER ON 30 nanoe G nanoe TECHNOLOGY nanoe X nanoe TECHNOLOGY OFF ON HEAT COOL nanoe TECHNOLOGY nanoe TECHNOLOGY...

Страница 17: ...17 AUTO OFF ON 1 2 AUTO OFF ON AUTO 3 COOL AUTO OFF ON 4 HEAT 3 AUTO OFF ON 5 AUTO OFF ON 5 AUTO OFF ON COOL HEAT 15 COOL 8 C 14 4 F HEAT 14 C 25 2 F HEAT 2 3...

Страница 18: ...14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 79 H 85 H 97...

Страница 19: ...19 Pb...

Страница 20: ...ime as 12 hour am pm or 24 hour 2 Press to confirm Use the remote control within 8 m from the remote control receiver on the indoor unit A new built in Network Adaptor that allows you to control your...

Страница 21: ...tely 10 seconds to show the temperature as C or F Table of Contents Safety Precautions 22 29 How to Use 30 31 To Learn More 32 Cleaning the Air Conditioner 33 Troubleshooting 34 36 Information 37 Acce...

Страница 22: ...e supervised to ensure that they do not play with the appliance Please consult an authorised dealer or specialist to clean the internal parts repair install remove disassemble and reinstall the unit I...

Страница 23: ...lectric shock nanoe G generator Do not touch the sharp pin which may cause injury Power supply Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire...

Страница 24: ...eal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use...

Страница 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 26: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 30: ...onsumption for better energy saving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO exit setting This operation combines both nanoe X and nanoe G nanoe TECHNOLOGY nanoe TECHNOL...

Страница 31: ...ion can be cancelled by pressing the respective button until the sleep timer reaches 0 0h SLEEP How to Use To connect to a network For Wireless LAN Module operation setup please refer to Setup Instruc...

Страница 32: ...tically with the last operation mode and airflow direction This control is not applicable when TIMER is set Inside Cleaning This function is to enhance the inside cleaning of the air conditioner indoo...

Страница 33: ...bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direc...

Страница 34: ...of materials used in plastic parts It is accelerated when exposed to heat sun light UV light or environmental factors After extended use dust may cover the front panel grilles and the wall surrounding...

Страница 35: ...TO OFF ON on the unit to select COOL HEAT mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temp...

Страница 36: ...sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe te...

Страница 37: ...be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a mildly f...

Страница 38: ...Memo...

Страница 39: ...Memo...

Страница 40: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 35730 SY0822 0...

Отзывы: