Rasmussen DF-CF15 Скачать руководство пользователя страница 8

 

 Wireless  

On/Off Remote  

with Thermostat  

(THR-2R) 

Wireless Wall  

Thermostat 

(TS-2R) 

 Wireless Wall  

Switch  

(WS-2R) 

    Wireless Wall Timer  

    (Up to 120 Minutes) 

             (WT-2R) 

Wireless 

 On/Off Remote  

(SR-2R) 

WARNING: 

 

AN “EASY” SAFETY PILOT MUST BE INSTALLED ON ALL UNITS 30” OR UNDER DESIGNED OR CONVERTED TO 

BURN  PROPANE GAS. THE  “EASY” SAFETY PILOT CONTROL SYSTEM IS OPTIONAL FOR NATURAL GAS UNITS. 

SPK3E 

Manual Safety Pilot Control 

 

RMC1E 

Wireless Variable Flame Height Remote Safety Pilot "EASY" Control.  

 

RPK3E 

Remote Ready Safety Pilot "EASY" Control. 

 

The Manual Safety Pilot Control (standing pilot) provides safety shutdown in 

the event of an interruption of the gas supply or flameout. It also provides a 

convenient means of lighting the burner and controlling flame height. A safety 

control is required for all propane installations, advisable for natural gas, and 

is required for certain jurisdictions. "EASY" control allows for upgrade to re-

mote operation at a later time. Refer to individually supplied instructions. 

Light the burner and adjust the flame height with the 

hand-held wireless remote transmitter. Provides safety 

shutdown in the event of an interruption in the gas supply 

or flameout. It also provides a convenient means of  

lighting the main burner. A safety control is required for 

all Propane installations, is advisable for natural gas, and 

is required in certain jurisdictions. (Comes with Variable 

Flame Height Remote Control Transmitter, and Remote 

Receiver) Refer to individually supplied instructions. 

Requires one of the Wireless Remoter Transmitter Devices (below) to light the main burner. Adjust the 

flame height manually by turning the knob at the valve. Provides safety shutdown in the event of an 

interruption in the gas supply or flameout. Also provides a convenient means of lighting the main 

burner. A safety control is required for all Propane installations, is advisable for natural gas, and is re-

quired in certain jurisdictions. The RPK3E Model  comes with the Remote Receiver shown below left and 

may be controlled by any one of the five Wireless Remote Transmitter Devices shown here (each sold sepa-

rately) Refer to individually supplied instructions. 

If utilizing the “EASY” Safety Pilot System with your Flaming Ember Burner use the individually 

supplied instructions in conjunction with this instruction manual before continuing. 

Содержание DF-CF15

Страница 1: ...asoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installatio...

Страница 2: ...r near the appliance Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc I...

Страница 3: ...u 60 15 Pilot Thermogenerator for Millivolt System JPG9 NG LP 16 Pilot Thermocouple J95R NG LP 17 Valve Knob Extender for Optional Manual EASY Safety Valve STV KE2 18 All Propane Burners 30 and under require an EASY Safety Pilot Kit shown below Optional for Natural Gas A SPK3E Manual EASY Control B RPK3E Remote Ready EASY Control C RMC1E Variable Flame Height EASY Control 1 Burner Pan DF CF18 20 2...

Страница 4: ...closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi GENERAL INSTALLATION INSTRUCTIONS WARNING CHECK FOR PROPER VENTING A properly sized unobstructed chimney will normally vent all products of combustion Any odor or smoke detected inside the room is an indication that the flue is not functioning properly SHU...

Страница 5: ...rom the firebox Figure 3D If using an Easy Safety Pilot Kit or a Millivolt System with this unit consult those instructions now then continue with Pan Medium Placement on pages 9 and 10 FIGURE 3 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury Depth Width B Gr...

Страница 6: ...ace between Gas Supply Pipe and Firebox floor allows the flared end of the 1 2 FIP x 3 8 Elbow should face down Figure 5A 2 With Burner Pan inside firebox at previously marked position thread one end of the Flex Connector Figures 5C to the 1 2 FIP x 3 8 Flared Elbow and wrench tighten Do not use pipe compound or tape on any flared threads 3 Thread Orifice Holder Figure 5D into burner pipe and wren...

Страница 7: ...using pipe compound or Teflon tape into 3 8 V 17 Valve Figure 6D then thread Valve into 3 8 Elbow and wrench tighten into position shown 3 Insert Key Sleeve Figure 6E over V 17 Valve Stem Figure 6F A 3 8 Street Elbow B Burner Pipe FIGURE 6 1 Thread 1 2 FIP x 3 8 Flared Elbow Figure 7A onto the Gas Supply Pipe Figure 7B and wrench tighten If space between Gas Supply Pipe and Firebox floor allows th...

Страница 8: ...mote transmitter Provides safety shutdown in the event of an interruption in the gas supply or flameout It also provides a convenient means of lighting the main burner A safety control is required for all Propane installations is advisable for natural gas and is required in certain jurisdictions Comes with Variable Flame Height Remote Control Transmitter and Remote Receiver Refer to individually s...

Страница 9: ...ilot Kit Propane sets 36 and over must use an RPK1 Millivolt system Both are optional for natural gas The EIS Electronic Ignition System is optional for all sizes Natural Gas or Propane Consult individually supplied instructions when using any control system Propane Sets 36 and over Propane Sets 30 and under Orifice holder 150 8 8 MA2 Air Mixer Orifice Spud A2T Orifice Holder MA2 Air Mixer Orifice...

Страница 10: ...IDUALLY SUPPLIED INSTRUCTIONS IN CONJUCTION WITH THIS INSTRUCTION MANUAL BEFORE CONTINUING DF CF24 USED BELOW FOR EXAMPLE ONLY RPK1 MILLIVOLT SAFETY PILOT LIGHTING CONTROL On Off Control with switch or remote lighting bottom of page Flame adjusts by turning knob RPK1 Heat Shield For RPK1 Valve On Off Ultrosonic F10AB On Off Remote with Thermostat RF THR 2R On Off Remote with Thermostat IR IRRC ...

Страница 11: ...ight covering of Ember Magic over the Pan Medium Figure 10 below Pull apart Ember Magic fiber material to enhance the glowing ember effect Spread remaining Ember Magic around ends of pan to add to the ember bed appearance When done the Burner Pan should look somewhat like the illustration below FIGURE 9 STEP FIVE PAN MEDIUM NATURAL GAS MODELS WARNING Wash hands after handling Ember Magic as it may...

Страница 12: ...de a propane burner pan 2 Sprinkle a light covering of Ember Magic over the Black Volcanic Ash Pull apart Ember Magic fiber material to enhance the glowing ember effect Spread remaining Ember Magic around ends of pan to add to the ember bed appearance When done the Burner Pan should look somewhat like the illustration below STEP FIVE PAN MEDIUM PROPANE MODELS WARNING Wash hands after handling Embe...

Страница 13: ...rner Pan as pan medium and sprinkled around the outside of the Burner Pan for a decorative effect Volcanic Ash may also be used to conceal the Flex Connector Figure 15C below WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury B Volcanic Ash used as floor dressin...

Страница 14: ... 2 3 HOURS AT A LOW FLAME SETTING TO ALLOW TEMPERING OF THE REFRACTORY LOGS FIGURE 18 Top View of 24 Double Face Lone Star log set FIGURE 19 Top View of 24 Double Face Crossfire log set WARNING During manufacturing assembly and packaging various components of this appliance are exposed to certain oils or films These are not harmful but may produce annoying smoke and smells as they are burned off d...

Страница 15: ...ighted match on embers near inlet end of burner Figure 21 DO NOT HOLD MATCH IN HAND Move away from front of fireplace 2 Slowly open Fireplace Gas Supply Valve and wait for burner to light 3 Adjust Fireplace Gas Supply Valve for desired flame height 4 To shutdown close Fireplace Gas Supply Valve completely BEFORE LIGHTING Smell around the burner area and next to floor for gas Some gas is heavier th...

Страница 16: ... Make sure the gas pressure coming into the fireplace does not exceed the maximum pressure allowed with this gas set refer to top of page 5 If you are using the gas logs with an EASY Safety Pilot Kit make sure you installed the correct orifice into the set refer to the table on page 4 Passage of air gas across irregular surfaces There may be burrs paint or other blockages on the burner bar ports C...

Страница 17: ...of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty does not extend to any product manufactured by RASMUSSEN which has been subjected to misuse neglect ac...

Отзывы: