background image

CHANGES  (2-03)
page 1: standard update z21.11.2a 2001  DUE  4-03; standard update z21.11.2b 2002  DUE  12-03
Title change: Customer Responsibilities And Annual Maintenance page 10

13

Содержание CHILLBUSTER 5

Страница 1: ...in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs...

Страница 2: ...s instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by...

Страница 3: ...peration 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not a...

Страница 4: ...Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr the...

Страница 5: ...floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may...

Страница 6: ...CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION Installing Chillbuster 5 Burner Unit Into Firepl...

Страница 7: ...oser the pieces the better the glowing ember effect WARNING Excessive amounts of Ember Material or Ember Material which is too tightly packed or exposed ports on Front or Middle burner can result in d...

Страница 8: ...ers Rear Burner All positions are controlled through the Valve Knob CAUTION Cycling rapidly between burner settings can result in VENTURI LIGHT OFF This is characterized by a loud air flow noise resul...

Страница 9: ...From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal instructions for individual Remote Accessory Options are included with t...

Страница 10: ...resistant log in which the CRACKLER Sound Generator option for both the F10 AB and IRRC wireless remotes may be located NORMAL OPERATING CHARACTERISTICS Each and every CHILLBUSTER that leaves the fact...

Страница 11: ...our log set When ordering parts always specify From information available on name plate attached to grate the following 1 Model number of the log set 2 Serial number of the log set 3 Type of gas natur...

Страница 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Страница 13: ...CHANGES 2 03 page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 13...

Отзывы: