ALL APPLICATIONS (INSTALLATION)

Fireplace/Firebox Sizing (VENTED and VENT-FREE):
1.

The minimum size (in inches) of the fireplace in which this CHILLBUSTER is to be installed must be as follows:

S E T

S I Z E

M O D E L

NUMBER

FRONT
WIDTH

HEIGHT

D E P T H

18
24
30

(HF)(18)-C5(A,B)-(M,S,R)-(N,P) (33,000,40000) BTU/HR
(HF)(24)-C5(A,B)-(M,S,R)-(N,P) (33,000,40000) BTU/HR
(HF)(30)-C5(A,B)-(M,S,R)-(N,P) (33,000,40000) BTU/HR

24
30
36

17
17
17

14
14
14

Gas Supply and Pressure (VENTED and VENT-FREE):
1.

Natural Gas:  The minimum inlet gas supply pressure for the purpose of input adjustment shall be 5 inches of 
water column.  The maximum inlet gas supply pressure shall be 7 inches of water column.

2.

Propane Gas:  The minimum inlet gas supply pressure for the purpose of input adjustment shall be 11 inches of 
water column.  The maximum inlet gas supply pressure shall be 14 inches of water column.

The Propane source must be regulated.   Never connect CHILLBUSTER directly to an unregulated Propane tank.

Preparation Of Fireplace (VENTED and VENT-FREE):
1.

Ensure firebox and chimney damper/flue are thoroughly cleaned (if previously used for either gas or wood 
burning.)

WARNING: Before installing in a solid fuel burning fireplace,

the chimney flue and firebox must be cleaned of soot, creosote, ashes

and loose paint by a qualified chimney cleaner.

2.

The area around the CHILLBUSTER must be clear and free from combustible materials, gasoline and any other 
flammable vapors and liquids. Provide adequate clearances for servicing and proper operation.

3.

Any outside air ducts and/or ash dumps in the fireplace shall be permanently closed at time of installation.

WARNING: Do not use a blower insert, heat exchanger insert or

other accessory not approved for use with this heater.

WARNING: Do not allow fans to blow directly into the fireplace.  Avoid any drafts

that alter burner flame patterns.

Pressure Testing (VENTED and VENT-FREE):
1.

Use Propane Gas resistant compound on all pipe fittings (not on connections with flared fitting).

2.  The CHILLBUSTER and its individual shutoff valve must be disconnected from the gas supply piping system 

during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).  The CHILLBUSTER 
must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any 
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

3.

Test new piping for leaks using soap solution. Do not use open flame to flame test.

VENTED INSTALLATION (Additional Requirements)

Damper Stop
Clamp

Damper

Chimney
Flue

General Information (VENTED):
1.  The minimum permanent free opening of the fireplace

chimney or chimney damper must be at least 2 9  sq. inches
based upon a minimum chimney height of at least 10 feet.

2.

Solid fuels shall not be burned in a masonry or UL 127 factory 
built fireplace where a CHILLBUSTER is installed.

Damper Clamp (VENTED):
2.

The  chimney damper must be fixed in a manner to maintain
permanent free opening as (outlined in item above) at all times.
To accomplish this, install the damper clamp (provided) on the
edge of the damper blade to prevent its closing, or drill holes in
the damper

   .

3

Содержание CHILLBUSTER 5

Страница 1: ...in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs...

Страница 2: ...s instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by...

Страница 3: ...peration 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not a...

Страница 4: ...Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr the...

Страница 5: ...floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may...

Страница 6: ...CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION Installing Chillbuster 5 Burner Unit Into Firepl...

Страница 7: ...oser the pieces the better the glowing ember effect WARNING Excessive amounts of Ember Material or Ember Material which is too tightly packed or exposed ports on Front or Middle burner can result in d...

Страница 8: ...ers Rear Burner All positions are controlled through the Valve Knob CAUTION Cycling rapidly between burner settings can result in VENTURI LIGHT OFF This is characterized by a loud air flow noise resul...

Страница 9: ...From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal instructions for individual Remote Accessory Options are included with t...

Страница 10: ...resistant log in which the CRACKLER Sound Generator option for both the F10 AB and IRRC wireless remotes may be located NORMAL OPERATING CHARACTERISTICS Each and every CHILLBUSTER that leaves the fact...

Страница 11: ...our log set When ordering parts always specify From information available on name plate attached to grate the following 1 Model number of the log set 2 Serial number of the log set 3 Type of gas natur...

Страница 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Страница 13: ...CHANGES 2 03 page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 13...

Отзывы: