Water
Solenoid
Valve
Shut-off
Valve
Toilet
Vacuum
Breaker
Pressurized
Water
Source
To
Toilet
Intake
Ù
Ù
Ù
Ù
Min. 6" (15.24cm)
From Pressurized
Freshwater Source
(Shut Off Valve)
To Toilet
IN
PLUMBING
WARNING: Hazard of potable water
contamination. The vacuum breaker must be
installed with any installation using a potable
water source.
IMPORTANT
•
Fittings and 90° bends should be kept to a
minimum.
•
Shut off valve must be installed where it is
easily acessible.
•
Use only quality reinforced hoses.
•
Secure all hoses properly.
Install a shut off valve in intake line before water
solenoid valve.
1. Connect hose from pressurized freshwater
source to a shut off valve.
2. Connect hose from shut off valve to inlet port
of water solenoid valve.
3. Connect hose from outlet port of water
solenoid valve to inlet port of vacuum breaker.
4. Connect hose from outlet port of vacuum
breaker to toilet inlet fitting.
OUT
Toilet Inlet
Fitting
Intake Hose from
Vacuum Breaker
INST
ALLA
TION
5