background image

Water

Solenoid

Valve

Shut-off

Valve

Toilet

Vacuum

Breaker

Pressurized

Water

Source

To

Toilet

Intake

Ù

Ù

Ù

Ù

 Min. 6" (15.24cm)

From Pressurized

Freshwater Source

(Shut Off Valve)

To Toilet

IN

PLUMBING

WARNING:  Hazard of potable water
contamination.  The vacuum breaker must be
installed with any installation using a potable
water source.

IMPORTANT

Fittings and 90° bends should be kept to a
minimum.

Shut off valve must be installed where it is
easily acessible.

Use only quality reinforced hoses.

Secure all hoses properly.

Install a shut off valve in intake line before water
solenoid valve.

1. Connect hose from pressurized freshwater

source to a shut off valve.

2. Connect hose from shut off valve to inlet port

of water solenoid valve.

3. Connect hose from outlet port of water

solenoid valve to inlet port of vacuum breaker.

4. Connect hose from outlet port of vacuum

breaker to toilet inlet fitting.

OUT

 Toilet Inlet

Fitting

 Intake Hose from

Vacuum Breaker

INST

ALLA

TION

5

Содержание TPWK12

Страница 1: ...NG RaritanEngineeringCompany Inc recommendsthataqualifiedpersonorelectricianinstallthis product Equipmentdamage injurytopersonnelordeathcouldresultfromimproperinstallation RaritanEngineeringCompany In...

Страница 2: ...chargeseacock 2 Shutoffintakewateratsource 3 Turn off power to unit 4 Disconnectanddraindischargehose It may be necessary to unbolt the toilet from thefloortogainaccesstothebackoftheunit 5 Disconnect...

Страница 3: ...idvalveandvacuumbreaker Wirecutters Wire terminal crimpers Tapemeasure INSTALLATION 3 Electrical SPECIFICATIONS Nominal Voltage Volts DC Amperage Draw Nominal Voltage Circuit Breaker Fuse Size Amps 12...

Страница 4: ...crews are recommended 3 Mountbracket 4 Install fittings provided PLA14 on valve s inlet and outlet ports 5 Attach valve to bracket Valve must be mountedaccordingtoflowmarkingsonvalve body MountingVacu...

Страница 5: ...pttoa minimum Shutoffvalvemustbeinstalledwhereitis easilyacessible Useonlyqualityreinforcedhoses Secureallhosesproperly Install a shut off valve in intake line before water solenoidvalve 1 Connect hos...

Страница 6: ...the unit hasbeenturnedoff WARNING HAZARD OF FLOODING Make sure seacocks and shut off valves are in the CLOSED or OFF positionbeforeworkingontoilet Any questions regarding servicing or operation should...

Страница 7: ...Beforeordering locaterequiredpartonexplodedpartsviewtobesureyouareorderingthecorrectpart Item Part No Description 1 CWPS A 1 2 Solenoid Valve 2 PLA14 3 Male Adapter 1 2 MPT x 3 4 Barb 3 CWPSMB Solenoi...

Страница 8: ...ipsupplied byothersintheprocessofinstallationofthisproduct defectscausedbyinstallationofthisproduct otherthaninaccordancewiththemanufacturer srecommendedinstallationinstructionsorstandard industryproc...

Отзывы: