Parts Included

Vacuum Breaker with fittings

Water Solenoid Valve with fittings

Water Solenoid Valve Mounting Bracket

Additional Parts Required

Two stainless steel toilet mounting bolts or

lag screws (1/4" [6mm])

3/4" (19mm) I.D. reinforced intake hose

3/4" (19mm) hose clamps

Wire

Terminals

Fuse/circuit breaker

Tools Required

Screw driver or nut driver (for hose clamps)

Hose cutter

Drill with bits (mounting the solenoid valve
and vacuum breaker)

Hole saw (routing the hose)

Screwdriver or wrench (mounting the
solenoid valve and vacuum breaker)

Wire cutters

Wire terminal crimpers

Tape measure

INST

ALLA

TION

3

Electrical

SPECIFICATIONS

Nominal Voltage (Volts DC)

Amperage Draw Nominal Voltage

Circuit Breaker/Fuse Size (Amps)

12

24

32

 

1

.5

.4

 

3

 

3

 

3

Wire Sizes

IMPORTANT:  Wire sizes are for Intake Pump Branch circuit only.

NOTE:  Recommended conductor sizes based on 105°C rated
insulation.  All voltages use 18 AWG (1.0 mm

2

) wire for water solenoid

valve branch circuit.

Plumbing

Atmospheric Vacuum Breaker with fittings

Water Solenoid Valve with fittings

Operating Pressures

   Minimum 5 psi (34 kPa)
   Maximun 150 psi (1,034 kPa)

2"

(5.08cm)

5"

(12.70 cm)

4" (10.16cm)

2 1/4"
(5.72cm)

4 1/4" (10.80 cm)

7" (17.78 cm)

t

t

t

t

t

t

t

t

t

t

t

t

Содержание TPWK12

Страница 1: ...NG RaritanEngineeringCompany Inc recommendsthataqualifiedpersonorelectricianinstallthis product Equipmentdamage injurytopersonnelordeathcouldresultfromimproperinstallation RaritanEngineeringCompany In...

Страница 2: ...chargeseacock 2 Shutoffintakewateratsource 3 Turn off power to unit 4 Disconnectanddraindischargehose It may be necessary to unbolt the toilet from thefloortogainaccesstothebackoftheunit 5 Disconnect...

Страница 3: ...idvalveandvacuumbreaker Wirecutters Wire terminal crimpers Tapemeasure INSTALLATION 3 Electrical SPECIFICATIONS Nominal Voltage Volts DC Amperage Draw Nominal Voltage Circuit Breaker Fuse Size Amps 12...

Страница 4: ...crews are recommended 3 Mountbracket 4 Install fittings provided PLA14 on valve s inlet and outlet ports 5 Attach valve to bracket Valve must be mountedaccordingtoflowmarkingsonvalve body MountingVacu...

Страница 5: ...pttoa minimum Shutoffvalvemustbeinstalledwhereitis easilyacessible Useonlyqualityreinforcedhoses Secureallhosesproperly Install a shut off valve in intake line before water solenoidvalve 1 Connect hos...

Страница 6: ...the unit hasbeenturnedoff WARNING HAZARD OF FLOODING Make sure seacocks and shut off valves are in the CLOSED or OFF positionbeforeworkingontoilet Any questions regarding servicing or operation should...

Страница 7: ...Beforeordering locaterequiredpartonexplodedpartsviewtobesureyouareorderingthecorrectpart Item Part No Description 1 CWPS A 1 2 Solenoid Valve 2 PLA14 3 Male Adapter 1 2 MPT x 3 4 Barb 3 CWPSMB Solenoi...

Страница 8: ...ipsupplied byothersintheprocessofinstallationofthisproduct defectscausedbyinstallationofthisproduct otherthaninaccordancewiththemanufacturer srecommendedinstallationinstructionsorstandard industryproc...

Отзывы: