background image

13

EXPLODED P

ARTS

PURASAN PARTS LIST

* 12VDC units are equipped with a 24VDC Macerator 

Motor, 24VDC units are equipped with a 32VDC 

Macerator Motor.

L519 _0919jlc 

Item  Part # 

Description  

  1  32-102AW  Mixer Motor 2 1/2” Dia. 12 V DC

  1  33-102AW  Mixer Motor 2 1/2” Dia. 24 VDC 

         (1) includes shaft seals and bushing for mixer motor)

  2  31-121 

Hose Fitting (2)

   

(Not shown)   90

)0 

hose fitting (PLA401)

  3  31-120 

Discharge Elbow 90

o

  6  31-134 

Cover Hold down Bolt, 10-32 x 1” (18)

  7  31-103 

Motor Shaft Bushing (2) (see 62)

  8  31-106 

Motor Hold down Bolt, 10-32x1”, S/S (4)

  9  31-109 

Mixer Impeller

10  31-110-1 

Impeller Bolt, 12-24 x 5/8”, S/S (2)

11  31-110-2 

Impeller Lock Washer, #12, S/S (2)

12  31-114 

Cover Hold down Nut, 10-32 (18)

13  31-115PS 

Treatment Tank

14  31-122  

Intake Plug

15  41-102 

Tank Divider

16  31-112 

Cover Gasket

17  31-108 

Macerator Set Screw

18  31-107 

Macerator Impeller

19  41-101W 

Treatment Cover (includes 56, 25,26)

22  33-101AW*  Macerator Motor  for 12 V DC unit

22  34-101AW*  Macerator Motor for  24 V DC

          ( Includes 31-304CW and 31-105 )

25  31-104CW  Crossover Plug with O-ring

26  31-105 

O-Ring 

51  M31 

#14 Brass Flat Washer (4)

52  M30 

1/4”-20 Brass Nut (4)

56  31-325A 

Adapter Tank Lid

57      221335 

Hose

58  41-170     

Tank check valve      

59      31-304C         Hose clamp

 

 

 

 

   

DRAIN MANIFOLD ASSY    42-137W (12V) 

                                 

        

43-137W (24V)

 

24  41-151A 

Adapter 

1

/

4

” x 

1

/

2

” elbow with check valve

27      42-145 

12 Volt Pull Solenoid 

 

43-145 

24 Volt Pull Solenoid

28  41-137 

Drain Manifold assy.(with check valve)

29   41-151B 

Adapter 

1

/

4

” x 

1

/

4

” elbow with check valve

30  41-141   

Adapter 

1

/

4

” NPT x 

1

/

2

” barbed

31      PLA3 

1

/

4

” Barbed x 

1

/

4

” NPT Adapter

32      41-139            Cap, manifold

33      41-138C         

1

/

4

” x 

3

/

4

” U cup seal

34  41-138 B        Plunger

35      41-138A         Washer for plunger

36      F204               6-32 x 3/8”” Flat head mach. screw(4)

37      LWS              Spring

38      F203              Washer 5/16” x 3/4”

39      F233       

Spring Roll Pin

50  41-187 

Shaft Boot 

 

 

53    41-152 

Base Plate

54  F232 

6-32 x 7/16” Flat head mach. screw (2)

55  F231 

Spacer  6” x 5/32”

62 

ESTRK          EST/PST Repair Kit includes following

TABLET DISPENSER  41-100AW

40  41-130A 

Dispenser Body.

41  41-177 

Adapter 1/2”NPT  x 1/2” barb

43      41-153 

Dispenser Basket

44      41-135A 

Purasan Tablets (sold saparately)

45      41-179          Float extension pipe

46  41-178W  

Float sensor

47  RWS5A 

“O” Ring

48  41-131M 

Dispenser Cap (machined)

85  41-505          Cable for Float sensor   

 

WATER VALVE 221351W (12V)

 

                    221352W 24V) 

 

64  221358W 

Inlet hose adapter - 90°  

65  221356W       Inlet hose adapter - straight

66  PX50W 

Double Check Valve assembly

67  221351 

Water Solenoid 12V

67      221352           Water Solenoid 24V

68      221335           1/2” Hose

69      41-157            Metering washer 

 

 

AIR PUMP for tablet dispenser 162000WA (12V)
 

                

   

            162100WA (24V)

70      166012A 

12 Volt Motor 

 

166024A 

24 Volt Motor

71      162000W       Intake Pump Assembly,air pump
72      162415A        Plug with barbed fitting

 

DIAPUMPRK    Diaphragm Pump Repair Kit   

 

CONTROLS

80      SPCCHNT  Purasan Control 
81      41-502          Wall Panel circuit board 
82      221514          ME: wall panel cover,white
83      221525          ME; wall panel gasket           
84  31-618          Cable for SPC  wall panel
86      EFC10          ATO fuse 10A

31-102 

Motor Shaft Seal (2)

31-102-1 

Macerator Seal Washer

31-102-2 

Macerator Retaining Ring

31-102-3 

Mixer Seal Washer

31-102-4 

Mixer Retaining Ring

31-103 

Motor Shaft Bushing (2)

31-105 

O-Ring

F351 

10-32x7/8'' w/ O-ring (4) 

31-112 

Cover Gasket

31-113-2 

Terminal Block Bolt (4)

31-114 

Cover Hold Down Nut, 10-32 (4)

SL1CC 

Super Lube

 OTHER (Not shown)

 

41-135A     Purasan Tablets (Refill)

 

42-1000A      Treatment Unit Complete 12V

 

43-1000A      Treatment Unit Complete 24V

 

212B10 

Key Switch Panel

 

 

90657 

Position Monitored Ball Valve

Содержание PURASAN EX Hold n' Treat

Страница 1: ...o personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOO...

Страница 2: ...lding tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 m...

Страница 3: ...level 3 If cycle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not...

Страница 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Страница 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Страница 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Страница 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Страница 8: ...FE tape or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one int...

Страница 9: ...odule Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing before connecting shutoff valve key swi...

Страница 10: ...PTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED 12AWG BLUE BLACK RED CABLE CABLE RED 86 30 87 85 FUSE 25 AMP 12...

Страница 11: ...you have left program mode Macerator Pump FIG 11 FILL EMPTY ERROR Treatment PROGRAMMING After hold time air pump and drain valve will drain solution Make sure that water is drained from entire tube u...

Страница 12: ...1 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 64 67 68 69 28 29 24 33 34 35 50 55 65 L51...

Страница 13: ...seal 34 41 138 B Plunger 35 41 138A Washer for plunger 36 F204 6 32 x 3 8 Flat head mach screw 4 37 LWS Spring 38 F203 Washer 5 16 x 3 4 39 F233 Spring Roll Pin 50 41 187 Shaft Boot 53 41 152 Base Pla...

Страница 14: ...QUENCE Note Fill time and Empty times are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank C...

Страница 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Страница 16: ...HER PERSONS FOR ANY SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE...

Отзывы: