background image

6

INST

ALLA

TION

Parts Included in the Box:

Control Module

16’ of Cable to 

Connect Switch 

Panel to Control 

Box

Air Pump

For Dispenser:

   6’ 

1

/

4

” ID tubing

    6’ 3/8” ID tubing

For Treatment unit:

6’ 

3

/

8

” ID tubing

Switch Panel Switch Panel 

Gasket

Tablet 

Dispenser

Inside the module:

 Drain Manifold  

 Water Valve

 SPC control box

6’ black and orange 

wire to connect tank

Fittings for 

Treatment 

Unit

Treatment unit

SensaLevel

sensor with 

cable

6’ black and red

wire to connect 

transfer pump

L519 _0919jlc 

Содержание PURASAN EX Hold n' Treat

Страница 1: ...o personnel that may result from improper installation or operation of this product WARNING HAZARD OF SHOCK AND FIRE Always use recommended fuse or circuit breaker and wire size WARNING HAZARD OF FLOO...

Страница 2: ...lding tank is above the LOW LEVEL treatment cycle starts Macerator pump is activated and moves approximately 1 gallon of waste from the holding tank to the treatment tank Treatment cycles runs for 2 m...

Страница 3: ...level 3 If cycle completes normal there is a 8 second pause before next cycle will start During this pause none of the buttons except No Discharge mode button is functional MAINTENANCE CAUTION Do not...

Страница 4: ...nstructions in the Owner s Manual for that particular toilet Recommissioning IMPORTANT Do not open shut off valve feeding control module until Treatment Tank is full Do not operate PURASAN EX until Tr...

Страница 5: ...er Size with macerator pump Fuse Specifications 3 1 4 8 3 cm 4 3 4 12 cm SWITCH PANEL DIMENSIONS Depth 8 22 3cm Width 16 40 6cm TREATMENT UNIT DIMENSIONS Height 13 34 3cm TABLET DISPENSER DIMENSIONS F...

Страница 6: ...ubing 6 3 8 ID tubing For Treatment unit 6 3 8 ID tubing Switch Panel Switch Panel Gasket Tablet Dispenser Inside the module Drain Manifold Water Valve SPC control box 6 black and orange wire to conne...

Страница 7: ...e wall FIG 6 Switch Panel Cable Supplied is 16 feet 1 Locate in head compartment where indicator lights will be visible 2 Using base plate mark the cutout for the panel See FIG 7 3 Route cable between...

Страница 8: ...FE tape or nonpermanent thread sealing compound on threaded PVC fittings and connections Avoid low areas in hose that would allow untreated waste to collect 1 Connect discharge of macerator to one int...

Страница 9: ...odule Using cable clamp secure cable on the wall near dispenser 2 Connect sensor cable to control module SPC Note Complete programming for Fill and Empty timing before connecting shutoff valve key swi...

Страница 10: ...PTIONAL SensaLevelTM BLACK WHITE OR RED BLACK WATER SOLENOID AIR PUMP DRAIN MAINIFOLD NEG POS 3 AMP FUSE TO POS TERMINAL BLACK 12AWG RED 12AWG BLUE BLACK RED CABLE CABLE RED 86 30 87 85 FUSE 25 AMP 12...

Страница 11: ...you have left program mode Macerator Pump FIG 11 FILL EMPTY ERROR Treatment PROGRAMMING After hold time air pump and drain valve will drain solution Make sure that water is drained from entire tube u...

Страница 12: ...1 22 57 48 47 46 45 44 43 40 41 70 71 80 81 85 84 86 82 83 72 27 39 37 38 36 32 54 53 36 31 30 58 41 137W 221351W 12V 221352W 24V 41 100AW 162000WA SPC 59 66 64 67 68 69 28 29 24 33 34 35 50 55 65 L51...

Страница 13: ...seal 34 41 138 B Plunger 35 41 138A Washer for plunger 36 F204 6 32 x 3 8 Flat head mach screw 4 37 LWS Spring 38 F203 Washer 5 16 x 3 4 39 F233 Spring Roll Pin 50 41 187 Shaft Boot 53 41 152 Base Pla...

Страница 14: ...QUENCE Note Fill time and Empty times are programmable Total treatment time is 120 seconds FILL CYCLE HOLD CYCLE EMPTY CYCLE DRAIN MANIFOLD PORTS Fig13 Water in Fill Air in Air to disp Empty To tank C...

Страница 15: ...tablet dispenser Press empty button to run air pump and clear any clog Clogged Check valve treatment tank adapter Clean or replace check valve 41 170 located on the tank Water fill time not programme...

Страница 16: ...HER PERSONS FOR ANY SPECIAL OR CONSE QUENTIALDAMAGES WHETHERARISING OUT OF BREACH OF WARRANTY BREACH OF CONTRACT OR OTHERWISE SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE...

Отзывы: