9
WIRING
WIRING
WARNING: Hazard of Shock and Fire
•
Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification
Chart.
•
Secure wire properly.
•
Do not connect other appliances to Purasan
circuit.
•
Make sure power is off before proceeding.
•
Improper wiring can damage the Circuit
Board and void warranty.
NOTE: Raritan recommends that the electric
toilet be installed for single touch operation.
Treatment Unit
1. Determine proper wire size from wire chart on
specifications page.
2. Run supply wire from source to Positive (POS)
and Negative (NEG) terminals on Treatment tank.
3. Fuse or circuit breaker must be installed between
source and Purasan on positive wire.
Switch Panel
1. Connect cable from Switch Panel to Circuit
Board as follows:
S1 to S1 - red wire
S2 to S2 - orange wire
L1 to L1 - green wire
L2 to L2 - white wire
S4 to S4 - black wire
Purasan Treatment Unit
+
_
Fuse/breaker per
specifications
_
+
Control Box
Switch Panel
S1- Red S2 - Orange L1 - Green L2 -
White
S4 - Black
- IN
S4
S6
S2
S3
S5
H1
L2
M2
+
L1
M1
+
S1
+
IN
- IN Battery Negative
S4 Black to switch panel
S6 Orange to switch panel #2
S2 Orange to switch panel #1
S3 (+) external out
S5 Auxiliary switch
H1 (-) to solenoid (Toilet #1)
L2 White to switch panel (s)
M2
+
(+) to mixer motor
L1 Green to switch panel (s)
M1
+
(+) to macerator motor
S1 Red to switch panel(s)
+
IN Battery Positive
WIRE CONNECTIONS - Not all connections will
be made, depends on installation options chosen
Battery
Control
F1 - Mixer
F2 - Macerator