background image

16

INSTALLATION OPTIONS FOR THE

electro scan SYSTEM

LIMITED WARRANTY

Raritan Engineering Company warrants to the original purchaser that this product is free of defects in materials or
workmanship for a period of one year from the product’s date of purchase.  Should this product prove defective by reason of
improper workmanship and/or materials within the warranty period, Raritan shall, at its sole option, repair or replace the
product.

1.

TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description of
the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW 2nd Ave. Ft. Lauderdale, FL 33315.  When
requesting warranty service, purchaser must present a sales slip or other document which establishes proof of purchase. THE
RETURN OF THE OWNER REGISTRATION CARD IS NOT A CONDITION PRECEDENT OF WARRANTY
COVERAGE.  However, please complete and return the owner Registration Card so that Raritan can contact you should a
question of safety arise which could affect you.

2.

THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or service of this product by
anyone other than Raritan; defects in materials or workmanship supplied by others in the process of installation of this product;
defects caused by installation of this product other than in accordance with the manufacturer’s recommended installation
instructions or standard industry procedures; physical abuse to, or misuse of, this product.  This warranty also does not cover
damages to equipment caused by fire, flood, external water, excessive corrosion or Act of God.

3.

ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH OF CONTRACT
WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW, IS HEREBY
EXCLUDED AND DISCLAIMED.  ALL IMPLIED WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND
OF FITNESS FOR A PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A TERM OF ONE YEAR.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A LIMITED WARRANTY LASTS, SO THE
ABOVE LIMITATION MAY NOT APPLY TO YOU.

4.

UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY OTHER PERSONS FOR
ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER ARISING OUT OF BREACH OF WARRANTY,
BREACH OF CONTRACT, OR OTHERWISE.  SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU.

5.

No other person or entity is authorized to make any express warranty, promise or affirmation of fact or to assume any other
liability on behalf of Raritan in connection with its products except as specifically set forth in this warranty.

6.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

530 Orange Street, Millville, NJ  08332 USA
Telephone:  856-825-4900

FAX:  856-825-4409

www.raritaneng.com
Southern Office and Plant:
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone:  954-525-0378

FAX:  954-764-4370

L340

1005kgs                                           Specifications Subject to Change Without Notice                  Printed in U.S.A.

The electro scan has a variety of installation options
including:
1) Installation on Inspected Vessels
2) Connection to the Sealand VacuFlush®
3) Automatic activation from a manual toilet

All of the above options are covered by Technical bulle-
tins available from Raritan by calling: 856-825-4900 or
faxing in a request at: 856-825-4409 or on our website at:
www.raritaneng.com

®Vacuflush is a registered trademark of Sealand Technology, Inc.

Содержание Electro Scan EST12

Страница 1: ...f any other substance is introduced by accident the electro scan must not be turned on until entire system is flushed out with water electro scan is a U S Coast Guard Certified Type I Marine Sanitatio...

Страница 2: ...void warranty How it works Each time the toilet is flushed an equal amount of previ ously treated waste is discharged The electro scan does not pump waste out The flushing action of the toilet moves...

Страница 3: ...time screen using and keys when unit is not in cycle Hold mode button until digits flash use and button to set hour in military time Push mode again for next digits minutes Use and to set minutes Rep...

Страница 4: ...OVERLD MIX MOTOR OVERLD MIX MOTOR OVERLD ERROR ERROR ERROR ERROR ERROR MaC MOTOR OVERLD MaC MOTOR OVERLD MaC MOTOR OVERLD MaC MOTOR OVERLD MaC MOTOR OVERLD ERROR ERROR ERROR ERROR ERROR ELECTROD OVERL...

Страница 5: ...ctions to ensure no damage is done to any components 3 Turn off power and disconnect wires to electro scan WARNING electro scan must not be activated while muriatic acid solution is in the system 4 In...

Страница 6: ...s and turn power on NOTE electro scan treatment tank must be full with sea water salinity water before activating a cycle 3 Flush toilet using one of the following methods to fill the treatment tank w...

Страница 7: ...a 2 2 s p m a 5 3 s p m a 5 3 w a r d p m a 2 2 r o t o M r o t a r e c a M s p m a 5 3 s p m a 0 3 w a r d p m a 0 2 s p m a 5 3 s p m a 0 3 w a r d p m a 6 1 s p m a 5 3 s p m a 0 3 w a r d p m a 9...

Страница 8: ...es Y valves if installed must direct toilet discharge to a U S C G approved treatment system or holding tank and must be secured in that position while inside the three mile limit The EPA standards st...

Страница 9: ...iring can damage the Circuit Board and void warranty Treatment Unit 1 Determine proper wire size from wire chart on specifications page 2 Run supply wire from source Positive POS to control unit and N...

Страница 10: ...let 1 or 2 outputs on control box utilizing 4 Connect wire from positive source to Raritan CDS solenoid relay post marked BAT utilizing proper fuse in positive line 5 When Start Stop button is pressed...

Страница 11: ...INTA KE BLUE TOILET CONTROL FROM LST ORANGE POS OFF FLUSH CONTROL PANEL DISCH WHITE ON 1 2 3 NEG BLAC K RARITAN AUX HEAD 2 HEAD 1 SALT FD NEG NEG NEG NEG MAN IN MAN IN EXT TRIG EXT TRIG FUSES HD NEG H...

Страница 12: ...12 This page left blank...

Страница 13: ...ry charge or replace Drop in line voltage Check voltage between pos post and negative post Other equipment on same circuit as Electro Scan Isolate Electro Scan Open or loose connections Check and clea...

Страница 14: ...5000 or 34 5000 31 112 31 109 31 103 31 106 31 110 2 31 110 1 31 110 2 31 110 1 31 106 31 107 31 108 31 103 31 101W 32 700 33 700 or 34 700 ETB2 31 705 31 702 M30 M31 31 113 2 31 134 32 101AW 33 101AW...

Страница 15: ...101W Treatment Cover 31 104C Crossover Plug 31 105 O Ring 31 102 Motor Shaft Seal 2 32 101AW Macerator Motor 3 Dia 12 VDC 33 101AW Macerator Motor 3 Dia 24 VDC 34 101AW Macerator Motor 3 Dia 32 VDC E...

Страница 16: ...FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW IS HEREBY EXCLUDED AND DISCLAIMED ALL IMPLIED WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE IF...

Отзывы: