ENGLISH
6
The table shows the messages that may appear on the control panel display and their solutions. If the message per-
sists, contact support.
Message
Description
Solution
---
The automatic control panel lock is active.
Hold the M button for 3 seconds.
rSt
The system requires a reset.
Reset.
E1/E7
Faulty power adapter.
Unplug the desk from the power source and then plug
it back in.
E2/E8
Different leg heights
Reset.
E5
The system detected a collision.
Remove all objects impeding movement.
E6/E12/E22
The system has diagnosed an unspecified
electronic error.
Unplug the desk from the power source and then
plug it back in. If the problem persists, have the
control box replaced.
HOT
System overheating.
The desk has been in use for more than
2 minutes in the last 18 minutes.
Allow the system to cool. Do not change the desk
height for about 18 minutes.
E11/E21
Motor connection error
Check the connection.
E13/E23
Defective motor cable
Check connections or replace cables.
E14/E24
Faulty/disconnected power cables
Check connections or replace cables.
E15/E25
Short-circuit
Replace motor.
E16/E26
The desk top is too laden and the motor
does not manage the weight of the top.
Remove items from the desk top and try again.
Always remove all heavy objects from the desk
before adjusting the height.
E17/E27
The desk top is moving in the
wrong direction.
Check connections or replace cables.
E18/E28
Desk overload
Remove items from the desk top and try again.
Always remove all heavy objects from the desk
before adjusting the height.
E42
Memory error
Replace the control box.
E43
Anti-collision sensors error
Replace the control box.
CLEANING
Disconnect the control panel cable end from the input port before cleaning.
Use only a dry, clean cloth for cleaning.
TROUBLESHOOTING