A78 Ground

B78 Lane 15 TX (P)

A79 Ground

B79 Lane 15 TX (N)

A80 Lane 15 RX (N)

B80 Ground

A81 Lane 15 RX (P)

B81 Presence detect (active low)

A82 Ground

B82 Reserved (N/C)

© 2017 - 2019 Raptor Computing Systems, LLC

C1P9S01 User's Guide Version 1.00

All Rights Reserved

https://www.

 

 raptorcs.com

48

Содержание C1P9S01

Страница 1: ...C1P9S01 Mainboard User s Guide For System Configuration and Set Up 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www raptorcs com...

Страница 2: ...CIFICATIONS 8 MAINBOARD OVERVIEW 10 Design 10 Installation 11 Removal 11 CPU INSTALLATION AND REMOVAL 12 Background 12 Installation 13 Removal 15 RAM INSTALLATION AND REMOVAL 16 Population Tables 16 I...

Страница 3: ...A Mode Switch 1 35 Chassis Intrusion Detect 36 On Board VGA Disable Jumper 37 Disk Drive Activity Indicator 38 External Audio Header 39 CPU Secure Mode Disable 40 PMBus Connector 41 CPU ATX12V Power C...

Страница 4: ...Updates 54 BMC Firmware Updates 54 EARLY BOOT DEVICE FIRMWARE 56 Introduction 56 Installation 56 Removal 56 SUPPORT 58 Getting Help 58 ERRATA 59 PCB Version 1 00 59 2017 2019 Raptor Computing Systems...

Страница 5: ...GES FOR LOSS OF PROFITS LOSS OF BUSINESS LOSS OF USE OR DATA INTERRUPTION OF BUSINESS AND THE LIKE EVEN IF RAPTOR COMPUTING SYSTEMS LLC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM...

Страница 6: ...power company If your power supply is not functioning do not attempt to repair it Contact a qualified service technician or your retailer OPERATIONAL SAFETY Before installing the motherboard or conne...

Страница 7: ...television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Страница 8: ...ximum Memory Type DDR4 1600 1866 2133 2400 2666 Memory Features ECC Module Sizes 8GB 16GB 32GB 64GB 128GB RDIMM Expansion Slots Total PCIe Slots 2 Total PCIe Ports 0 PCIe Generation 1 2 3 4 CAPI 2 Cap...

Страница 9: ...n 10 C 35 C Storage 40 C 70 C Humidity 20 90 non condensing NOTE Specifications are subject to change without notice 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights...

Страница 10: ...noise PCIe slots and peripherals are directly connected to each CPU for maximum bandwidth therefore PCIe slots cannot be split without an external PCIe switch card 2017 2019 Raptor Computing Systems L...

Страница 11: ...e remaining screws Torque all mainboard mounting screws to 7 ft lbs 0 8N m WARNING There are fragile electronic components located on the entire bottom surface of the mainboard Ensure that the mainboa...

Страница 12: ...e not vertical loosen the retention screw of the heatsink assembly and gently reposition the heatsink watching for the latching prongs to move into a vertical position NOTE Incorrectly positioned lock...

Страница 13: ...in an appropriate anti static environment Carefully remove the protective cover making sure not to touch any of the exposed socket pins 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Ver...

Страница 14: ...bly carefully center an indium pad on top of the CPU Place the heatsink assembly on top of the CPU following instructions given earlier 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Vers...

Страница 15: ...erse Start with step 5 turning the hex driver counterclockwise and end with step 1 replacing the socket protective cover into postion over the socket WARNING Before attempting to remove the heatsink e...

Страница 16: ...ABLES Quantity Slot Population Processor 1 A1 B1 1 DIMM X 2 DIMMs X X X denotes memory DIMM is installed in indicated slot 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All...

Страница 17: ...f memory is correct The C1P9S01 only accepts full size 288 pin DDR4 DIMMs and other types of memory will not seat or function DO NOT attempt to force a DIMM into a slot as this may cause permanent dam...

Страница 18: ...even pins are on one side of the header and all odd pins are on the other Single row headers use a monotonically increasing pin number starting from pin 1 Key pins are not physically present but are s...

Страница 19: ...an fail LED cathode 7 LED Anode 3 3V main power 8 Fan Fail LED Anode 5V main power 9 LED Anode 3 3V standby power 10 NIC 2 link activity LED cathode 11 LED Anode 3 3V standby power 12 NIC 1 link activ...

Страница 20: ...HDD activity LED cathode 15 3 3V main power 16 Power LED cathode 17 KEY 18 KEY 19 NMI button active low 20 Ground 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Re...

Страница 21: ...E J7701 Pin Function Pin Function 1 DCD 2 DSR 3 RXD 4 RTS 5 TXD 6 CTS 7 DTR 8 NRI 9 Ground 10 KEY 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www...

Страница 22: ...4 KEY 5 TPM reset active low 6 N C 7 LPC address data bit 3 8 LPC address data bit 2 9 3 3V main power 10 LPC address data bit 1 11 LPC address data bit 0 12 Ground 13 I2C clock 14 I2C data 2017 2019...

Страница 23: ...y power 16 LPC serial IRQ 17 Ground 18 N C 19 Window open active low 20 BMC GPIO B3 active low 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www ra...

Страница 24: ...Module presence detect 1 active low 7 Integrity loop 0 8 Integrity loop 0 9 LPC address data bit 3 secure 10 LPC address data bit 0 platform 11 LPC address data bit 2 secure 12 LPC address data bit 1...

Страница 25: ...re 26 LPC reset active low platform 27 BMC SPI MOSI secure 28 BMC SPI clock platform 29 BMC SPI clock secure 30 BMC SPI MOSI platform 31 BMC SPI MISO secure 32 BMC SPI MISO platform 33 BMC SPI chip se...

Страница 26: ...MODE J13023 Pin Function Pin Function 1 OCC alert active low 2 Ground current limited 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www raptorcs co...

Страница 27: ...ERNAL RESET HEADER J7000 Pin Function Pin Function 1 N C 2 BMC reset active low 3 Ground 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www raptorcs...

Страница 28: ...RY SERIAL HEADER J10116 Pin Function Pin Function 1 Ground 2 BMC COM2 RXD TTL 3 BMC COM2 TXD TTL 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www...

Страница 29: ...EAT INDICATOR HEADER J10114 Pin Function Pin Function 1 Ground 2 BMC heartbeat LED cathode 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www raptor...

Страница 30: ...3 SuperSpeed RX Port 4 positive polarity 4 Ground 5 SuperSpeed TX Port 4 negative polarity 6 SuperSpeed TX Port 4 positive polarity 7 Ground 8 Hub Port 1 negative polarity 9 Hub Port 1 positive polari...

Страница 31: ...polarity 15 SuperSpeed TX Port 3 negative polarity 16 Ground 17 SuperSpeed RX Port 3 positive polarity 18 SuperSpeed RX Port 3 negative polarity 19 5 0V USB power current limited 20 KEY 2017 2019 Rap...

Страница 32: ...MC I2C PORT 5 J6902 Pin Function Pin Function 1 BMC I2C SCL 2 Ground 3 BMC I2C SDA 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www raptorcs com 3...

Страница 33: ...ROGRAMMING HEADER J10104 Pin Function Pin Function 1 3 3V standby power 2 SCL 3 Ground 4 SDA 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www rapt...

Страница 34: ...Function Pin Function 1 Ground 2 SPI clock 3 SPI MOSI 4 SPI MISO 5 SPI slave select active low 6 3 3V standby power 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights...

Страница 35: ...E SWITCH 1 J7800 Pin Function Pin Function 1 Mode enable bit 1 active low pullup 2 Ground 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www raptorc...

Страница 36: ...J9900 Pin Function Pin Function 1 Intrusion detect active low pullup 2 RTC battery 3 0V current limited 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved ht...

Страница 37: ...e a jumper cap on these two pins to disable the on board VGA output This may be useful when installing a discrete GPU to avoid operating system bugs related to having two VGA devices installed 2017 20...

Страница 38: ...INDICATOR J10120 Pin Function Pin Function 1 Ground 2 Disk drive activity signal active low pullup 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https w...

Страница 39: ...t Microphone In 2 Ground 3 Right Microphone In 4 HDA Detect Controller GPIO1 5 Right Speaker Out 6 N C 7 N C 8 Key 9 Left Speaker Out 10 N C 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide...

Страница 40: ...600 Pin Function Pin Function 1 N C 2 Secure Mode Disable active high 3 1 1V standby power current limited 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved...

Страница 41: ...Pin Function Pin Function 1 I2C SCL 2 I2C SDA 3 Alert active low open drain 4 Ground 5 3 3V main power 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved htt...

Страница 42: ...TOR J10101 Pin Function Pin Function 1 Ground 2 Ground 3 12V ATX 12V main power 4 12V ATX 12V main power 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved ht...

Страница 43: ...r 2 3 3V main power 3 Ground 4 5 0V main power 5 Ground 6 5 0V main power 7 Ground 8 ATX power good active high 9 5 0V standby power 10 12V main power 2017 2019 Raptor Computing Systems LLC C1P9S01 Us...

Страница 44: ...15 Ground 16 ATX power enable active low 17 Ground 18 Ground 19 Ground 20 No connection 21 5 0V main power 22 5 0V main power 23 5 0V main power 24 Ground 2017 2019 Raptor Computing Systems LLC C1P9S0...

Страница 45: ...B1 12V main power A2 12V main power B2 12V main power A3 12V main power B3 12V main power A4 Ground B4 Ground A5 JTAG TCK N C pull down B5 SMBus Clock 2017 2019 Raptor Computing Systems LLC C1P9S01 Us...

Страница 46: ...Lane 1 TX N A21 Lane 1 RX N B21 Ground A22 Lane 1 RX P B22 Ground A23 Ground B23 Lane 2 TX P A24 Ground B24 Lane 2 TX N A25 Lane 2 RX N B25 Ground A26 Lane 2 RX P B26 Ground A27 Ground B27 Lane 3 TX P...

Страница 47: ...8 Lane 10 TX P A59 Ground B59 Lane 10 TX N A60 Lane 10 RX N B60 Ground A61 Lane 10 RX P B61 Ground A62 Ground B62 Lane 11 TX P A63 Ground B63 Lane 11 TX N A64 Lane 11 RX N B64 Ground A65 Lane 11 RX P...

Страница 48: ...B79 Lane 15 TX N A80 Lane 15 RX N B80 Ground A81 Lane 15 RX P B81 Presence detect active low A82 Ground B82 Reserved N C 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Ri...

Страница 49: ...ER J7902 Pin Function Pin Function 1 Ground 2 12V main power 3 Tachometer input 4 PWM output 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www rapt...

Страница 50: ...EADERS J7900 J7901 Pin Function Pin Function 1 Ground 2 12V main power 3 Tachometer input 4 PWM output 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved http...

Страница 51: ...J9006 Pin Function Pin Function 1 Ground 2 Lane 0 Tx P 3 Lane 0 Tx N 4 Ground 5 Lane 0 Rx N 6 Lane 0 Rx P 7 Ground 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights R...

Страница 52: ...fan to full speed if one of the CPU fans is disconnected or is non functional in a dual CPU system If a fan fails during system operation an alert will be set for that zone and all fans within the zo...

Страница 53: ...ccess press the power button on your chassis Within a few seconds the system should initiate the IPL cycle and in about 10 seconds the front panel will start showing IPL status information on the ID N...

Страница 54: ...to request an IP address via DHCP Once it is connected and has a valid IP address you can log in via SSH using the following default credentials Username root Password 0penBmc NOTE It is strongly rec...

Страница 55: ...during any BMC firmware update there is a possibility that the update process may result in a non functional BMC Recovery of the BMC in this situation would requiring external programming of the socke...

Страница 56: ...you wish to install in a dedicated directory for example tmp firmware Execute the squashfs image creation command as follows cd tmp firmware mksquashfs firmware_squashfs_image bin all root keep as di...

Страница 57: ...from loading you can do so from a BMC shell using the following command pflash P BOOTKERNFW e 2017 2019 Raptor Computing Systems LLC C1P9S01 User s Guide Version 1 00 All Rights Reserved https www rap...

Страница 58: ...ectly at support raptorcs com Alternatively we also have a Wiki and other support resources available online at https www raptorcs com the information you require may already be available on one of th...

Страница 59: ...I transceiver from the host is not possible The main impact is to effectively disable HDMI autoconfiguration though the HDMI port may still be used normally with manually configured resolutions 2017 2...

Отзывы: